Page 35 - 2023 Shimadzu Analytical and Measuring Instruments
P. 35

UV-VIS-NIR Spectrophotometers /
                                                                                               FTIR Spectrophotometers



          Photoreaction Evaluation System                     Fourier Transform Infrared Spectrophotometer
          Lightway                                            IRSpirit                                                 Chromatography Systems



















          Lightway is the world's first* photoreaction evaluation system designed   IRSpirit is a compact Fourier Transform Infrared Spectrophotometer that   Mass Spectrometry Systems
          for the photochemistry field. It provides support for evaluating   travels where it's needed. It gracefully accommodates available bench
          photoreaction quantum yield rates. By streamlining previous experiment   space and the sample compartment is easily accessible with the system
          process steps, it enables results to be obtained even more quickly. In   facing forward or sideways. In addition, IRSpirit is equipped with the   Life Science Lab Systems
          addition, the software includes navigation functionality that allows even   widest sample compartment in its class, to easily accommodate both
          inexperienced users to operate the system easily. It eliminates the need   Shimadzu and third-party accessories. IRSpirit also offers the highest S/N
          to adjust the chemical actinometer, which minimizes operator variability   ratio (30,000:1) in its class using the technology inherited from the
          and helps ensure accurate measurement results.      high-end model. Furthermore, a newly developed dedicated IR Pilot
          * As of May 2020, according to a Shimadzu survey    program offers 23 standard application programs to simplify analysis for
          Wavelength range  250 to 800 nm                     all users.
          Spectral bandwidth  15.0 nm                                     Michelson interferometer (30° incident angle)
          Photometric interval  0.1 sec. to 60 min.            Interferometer  Equipped with Dynamic Alignment system  Spectroscopy Systems
          Photometric range  Absorbance: 0 to 1.5 Abs                     Sealed interferometer with desiccant
                                             Brochure No. C101-E174  Wavenumber range  7,800 to 350 cm −1
                                                               Highest resolution  0.9 cm −1
                                                                                                  Brochure No. C103-E114

          Fourier Transform Infrared Spectrophotometer        Fourier Transform Infrared Spectrophotometer Plastic Analysis System
          IRTracer-100                                        Plastic Analyzer                                        Systems  X-ray and Surface   Analysis



















          This system achieves excellent sensitivity with an S/N ratio of 60,000:1,   When analyzing plastics, libraries are used to qualify their material   Measurement Systems  Environmental
          high resolution at 0.25 cm , and high-speed scanning capable of 20   properties. However, infrared spectra of plastics that have been
                            −1
          spectra/second. The performance of medium and higher end models is   denatured (have deteriorated) due to heat or UV rays differ in shape
          supported by high reliability including advanced dynamic alignment and   from standard spectra, and qualifying them can sometimes be difficult.   Systems  Non-Destructive Inspection     Material Testing and
          an interferometer with a dehumidifier. This is compatible with   To address this, the Plastic Analyzer includes a deterioration library, so
          applications active in a variety of circumstances, with a library of   highly accurate qualification can be performed reflecting the state of
          approximately 12,000 spectra and data analysis programs for   deterioration.
          contaminant analysis, and time course and rapid scan programs for   IRSpirit Fourier transform infrared spectrophotometer
          reaction tracking.                                              QATR-S single-reflection ATR attachment
                                                                          Plastic Analyzer method package
                     Michelson interferometer (30° incident angle)  Contents  • UV-Damaged Plastics Library
          Interferometer  Equipped with Advanced Dynamic Alignment system  • Thermal-Damaged Plastics Library
                     Sealed interferometer with automatic dehumidifier    • Macro Program for IR Pilot/Parameter File  Measurement Systems  Physical Properties
          Wavenumber range  7,800 to 350 cm  (standard), 12,500 to 240 cm  (optional)             Brochure No. C103-E130
                               −1
                                                −1
          Highest resolution  0.25 cm −1
                                             Brochure No. C103-E091
                                                                                                                    35
   30   31   32   33   34   35   36   37   38   39   40