Simplifies Time-Consuming Method Development Processes







                Nexera Method Scouting System Automates Method Development Processes
            The Nexera Method Scouting method development system, which can accommodate up to six columns and eight mobile phases,
            is capable of automatically switching between up to 96 combinations of columns and mobile phases. This means data can be acquired
            even at night, which is typically down-time, thus making highly efficient method development possible.
                              Scouting


                         Method Scouting Solution
                         Method
                                        ion
                                    Solut
                                                           LC-30AD
                                                                           FCV-34AH
                                                                   MR180 µL
                                                                    Mixer
                                                                                                   PDA
                                                                    SIL-30AC
                                                                                   Column
                                                           LC-30AD
                                                                                          Manifold
                                                                                  CTO-20AC


                                                   LPGE Unit
                      Nexera Method Scouting System     Basic configuration of the Nexera Method Scouting System





                Not Only Automates Data Acquisition, but Significantly Reduces Labor Required for Preparation
            The Nexera Method Scouting system is not only able to significantly
            reduce the labor hours required for preparation, it also helps avoid
            human error involved in configuring method file and schedule
            settings. Considering it can accommodate up to six columns, eight
            types of mobile phases, and 10 types of gradient settings, it is
            potentially capable of providing 960 combinations. Configuring
            method file and schedule settings manually would not only take
            time, but could result in inadvertent errors.



                                                                   Simply select the checkboxes for mobile phases and columns to use,
            Solvents used in mobile phase blending can also be managed in a   and a method will be created automatically.
            database, in the same manner as for scouting. This allows you to
            select them conveniently via a graphical user interface.


                                                                               Approx.



                                                                Organic solvent
                     Organic solvent
                      Methanol
                      Acetonitrile                                Acetonitrile
                      THF
                      Ethanol                                     Methanol
                      AcN-MeOH                                    THF
                                                                  Ethanol      Approx.
                                                                  AcN-MeOH