Page 8 - Shimadzu Nexera XS inert
P. 8

Full-range of Bio-inert UHPLC Capabilities







                     The Nexera XS inert system eliminates the risk of sample adsorption or surface corrosion, while still providing all the   Finger-Tightened Fittings for Simple and Secure Connections
                     exceptional features of the Nexera series, making it the perfect solution for a wide variety of applications.
                                                                                                                                        Nexera XS inert systems feature tubing connections with unique finger-tightened fittings. They can achieve joints with
                                                                                                                                        up to 105 MPa of pressure capacity by finger-tightening and without creating any dead volume.



                                                                      Nexera XS inert combines excellent resistance to corrosion
                                                                      with the inertness of surfaces in contact with the sample
                                                                      and mobile phases. The system provides excellent
                                                                      chromatographic separation performances for a wide
                                                                      range of applications.




                                                                         System Controller
                                                                         SCL-40, CBM-40/40lite
                                                                         Used to coordinate actions of the overall system, this
                                                                         controller offers intuitive operation that minimizes
                                                                         the stress involved in operating the system, from              Flow Channel Switching Valves for Metal-absorbing Compounds
                                                                         startup to shutdown.
                                                                                                                                        All valves used in Nexera XS inert systems are designed to inhibit metal adsorption. That ensures worry-free switching
                                                                                                                                        between multiple columns for method development or even for trap-and-elute analysis without being concerned
                                                                         Detector                                                       about adsorption.
                                                                         SPD-40/40V/M40
                                                                         Inert type cells for UHPLC analysis eliminate the risk of      FCV-0206H2i
                                                                         adsorption on the detector. Low-diffusion cell, which          2-Position/6-Port Valve
                                                                                                                                                                                                                 Columns
                                                                         has 5 mm of optical path length, can also be selected.
                                                                                                                                                                                          Solvent
                                                                                                                                                                                        delivery unit
                                                                                                                                                                                                                             Detector
                                                                         Solvent Delivery Unit
                                                                                                                                               Used to automatically switch between
                                                                         LC-40D XSi                                                                columns and detectors.
                                                                                                                                                                            Flow line switching unit  Auto Sampler
                                                                         Designed with corrosion-resistant non-stainless steel                                            (Built into solvent delivery unit)
                                                                         materials, it offers rugged, low-pulsation perfor-             FCV-0607H2i
                                                                         mance, advanced AI features and solvent blending               6-Position/7-Port Valve
                                                                                                                                                                                                              Flow line switching valve
                                                                         capabilities. (optional).                                                                                        Solvent
                                                                                                                                                                                        delivery unit          Column oven

                                                                         Autosampler                                                                                                             Method Scouting System
                                                                         SIL-40C XSi                                                            Used to switch between up to six  Flow line switching unit
                                                                                                                                                columns for method development.  (Built into solvent delivery unit)
                                                                         This high-performance autosampler features non-
                                                                         metal materials for all surfaces that contact liquids.
                                                                         That inhibits metal-adsorption of biomolecules.

                                                                                                                                        Mobile Phase pH Monitor: pHM-40  (optional)
                                                                         UHPLC Inert Switching Valve
                                                                                                                                        In the case of Ion-exchange chromatography or size-exclusion chromatography used for
                                                                         FCV-0206H2i/FCV-0607H2i
                                                                                                                                        the analysis of proteins or other biomolecules, the mobile phase pH can strongly affect
                                                                         Designed with adsorption-inhibiting materials for all
                                                                                                                                        chromatographic separation. The pH monitor pHM-40 continuously monitors the pH of
                                                                         wetted surfaces (refer to p. 9).
                                                                                                                                        mobile phases to identify any changes in mobile phase pH in real time.