Page 11 - Shimadzu Nexera XS inert
P. 11

Comprehensive Solution for Increasing

 Bioseparation Efficiency




 Adsorption of biomolecules can occur not only within instruments, but also in vials, columns, and other equipment   Selecting Analytical Columns Based on Target Components and Objectives
 used during sample preparation. Shimadzu offers support for resolving such issues with products that feature unique
               Shim-pack  Series Columns
                         ™
 technologies for inhibiting adsorption.
               Analyzing biomolecules, such as proteins and nucleic acids, requires using columns intended for a variety of separation
               modes. In particular, samples sensitive to metal ions require a column that is optimized to reduce adsorption.
               Shimadzu offers columns optimized for a wide variety of molecules.




                                                                                    Shim-pack Scepter
                                                            Reversed phase

               Nucleic Acids                                                        Shim-pack Bio IEX
               Oligonucleotides                              Ion exchange

                                                                                    Shim-pack Bio Diol
                                                             Size exclusion

                                                                                    Shim-pack Arata
                                                                                    Shim-pack Velox
                                                            Peptide digests
                                                                                    Shim-pack Bio Diol
                                                         Aggregates and Fragments
               Antibodies,
 State-of-the-Art Technology for Inhibiting Adsorption and Increasing   Antibody Drug Conjugates  Shim-pack Bio IEX
                                                            Charge variants
 Recovery Rates                                                                     Shim-pack Bio HIC
                                                              Conjugates
 TORAST-H Bio Vials

 Biomolecules are most likely to adsorb to vials they contact the longest. TORAST-H Bio vials offer exceptional resis-
 tance to adsorption by biomolecules, which helps maximize recovery rates from valuable samples and increase
 sensitivity for analyzing trace components.



 uV  uV
 30000
 Basic compound A  : TORAST-H Bio Vial  4000  Basic compound B  : TORAST-H Bio Vial
 logP : 4.9   (100%)  logP : 0.16   (100%)
 20000  pKa : 9.4  : Other vender's vial A  3000  pKa : 9.6  : Other vender's vial A
  (80%)   (86%)
 : Other vender's vial B  : Other vender's vial B
  (38%)  2000   (69%)
 10000
 1000
 0
 1.5  2.0  2.5  3.0 min  1.0  1.2  1.4  1.6  1.8  2.0  2.2  min
 uV  uV
 30000  50000
 Basic compound C  : TORAST-H Bio Vial  Basic compound D  : TORAST-H Bio Vial
 logP : 4.8   (100%)  40000  logP : 3.4   (100%)
 20000  pKa : 9.4  : Other vender's vial A  pKa : 9.1  : Other vender's vial A
  (85%)  30000   (77%)
 : Other vender's vial B  : Other vender's vial B
 10000   (36%)   (18%)
 20000
 10000
 0
 0
 1.0  1.5  2.0  2.5  min  1.1  1.2  1.3  1.4  1.5  1.6  1.7  min

 10                                                                                                               11
   6   7   8   9   10   11   12   13   14   15   16