Page 15 - Shimadzu AA-7800 Series
P. 15

Any Location







 World’s Smallest Dual System  LabSolutions  CS Supports Laboratory Network Connectivity
                                 ™



 Despite being a dual atomizer, the unit is only 940 mm wide   Adding a WizAArd Agent connection kit (optional) enables compliance with electronic recordkeeping and electronic
 (including the power supply unit for the graphite furnace   signature regulations, such as requirements specified in FDA 21 CFR Part 11. Select either a standalone (LabSolutions DB) or
 atomizer).    networked (LabSolutions CS) system that is best for the given application.
                     LabSolutions CS manages all analytical data in a database on a network server, so that the data can be loaded and
 610mm
               analyzed on any computer connected to the network.
               Note: An additional software license is required for analyzing data onto a computer not connected to the AA system.

                                                                       * 3                   * 2
 940mm              LabSolutions server   Laboratory or office   Tablet              Client PC
 AA-7800/AAC Dual Atomizer System Dimensions
 (Top surface)
 Note: The indicated size does not include the ASC-7800 unit.

 Compact and Multifunctional Autosampler  * 1
                  Acquisition
 ASC-7800        cotoroller PC

 The Same Autosampler can be Used for
 Both Flame and Furnace Measurements

 A single autosampler can be used for both flame and furnace
                            LC   GC        Agilent LC, GC  Thermo LC, GC        EDX   TOC-V    AA
 measurements. There is no need to prepare two autosamplers.
 The simple design allows for sliding the autosampler left or                  Combine with
                                                                               Multi-Data Registration License
 right.                                                                        to enable integrated management
 During Flame Measurements  During Furnace Measurements                        of these instruments’ data.
 Space-Saving Design

 Connecting the autosampler directly to the main unit minimizes
 installation space and simplifies maintenance.  LCMS  GCMS  FTIR  UV  RF  TA
                                                                                PC



 Low Carryover
 Flame analysis requires being careful of carryover. The ASC-7800   Discharge
 rinses the nozzle at the overflow mechanism rinse port after                  A instrument  B instrument
 each sample measurement is finished, which keeps carryover                    Combine with
 below 10  even when measuring multiple samples.  Balance  PPSQ ™  ICPMS  Particle Size  AG  TOC-L  Multi-Data Registration License
 -4
                                                Analyzer                       to enable integrated management
                *1  The acquisition control PC controls analytical instruments.
 Conventional  Overflow         It can also be used to send analytical instructions and perform postrun analysis, just like a client PC.
 Method  Method  *2  If a terminal service is used, then LabSolutions software does not need to be installed on client PCs.
 Advanced Functionality  *3  If an iPad is used, then XenApp from Citrix must be installed.

 Up to four kinds of samples (such as diluents, standard solutions,
 samples, or matrix modifiers) can be mixed together before
 injection. (Non-mixtures can also be injected, of course.) Either a   Software Required for Using the System Connected to LabSolutions
 fluoropolymer tube or pipette tip can be selected as the   Part Name  P/N      Remarks
 injection nozzle. Samples can be automatically diluted and   WizAArd Agent Connection Kit  206-77741-92
 remeasured if the concentration exceeds the calibration curve   LabSolutions Manager DB Multi-Data Registration Function  223-19127-92  Standalone System
 concentration range.  LabSolutions Manager CS Multi-Data Registration Function  223-19169-92  Network System
                WizAArd Second License               206-59774-41  Requires when installing WizAArd to a PC other than the control PC.



 14                                                                                                               15
   10   11   12   13   14   15   16   17   18   19   20