Software




                     New LabSolutions  ICPMS Software                                                                                   LabSolutions  CS Supports Laboratory Networking
                                            ™
                                                                                                                                                         ™
                     The new version of LabSolutions ICPMS software displays all necessary information in a single                         LabSolutions server   Laboratory or office     Tablet  *3           Client PC  *2
                     window, simplifying operation for new users. Experienced users can utilize advanced configurable
                     settings for challenging applications, in-depth research and all analyses in between.

                                                               Analysis Window
                                                                                                                                                      *1
                                                               The customizable analysis window can simultaneously                          Acquisition
                                                                                                                                            controller PC
                                                               display the current sample profile, registered
                                                               samples, analytical results, errors, and instrument
                                                               status. The analysis progress can be  monitored at a
                                                               glance. Windows can be configured and customized
                                                               based on the user's preference. The assistant bar                                                                                     EDX    ICPE  TOC-V    AA
                                                               along the left side guides the users through every                                   LC   GC      Agilent LC, GC  Thermo LC, GC       Combine with
                                                               step of analysis in the correct order.                                                                                                Multi-Data Registration License
                                                                                                                                                                                                     to enable integrated management
                                                                                                                                                                                                     of these instruments’ data  and
                                                                                                                                                                                                     user information.

                                                               Instrument Status Window
                                                                                                                                              LCMS       GCMS      FTIR    UV      RF      TA
                                                               The instrument status window displays information
                                                               about the instrument and accessories in a compre-                                                                                       PC
                                                               hensive and easy-to-understand layout.
                                                               A warning indicator is displayed if an error occurs or
                                                               if a part is due for maintenance or replacement.
                                                                                                                                                                                                       A instrument  B instrument
                                                                                                                                                                                                    Combine with
                                                                                                                                            Balance  PPSQ ™  ICPMS   Particle Size  AG   TOC-L      Multi-Data Registration License
                                                                                                                                                                       Analyzer                     to enable integrated management
                                                               Automatic Internal Standard Monitoring                                   *1  The acquisition control PC controls analytical instruments. It can also be used to send analytical instructions and perform postrun
                                                                                                                                           analysis, just like a client PC.
                                                               Internal standard fluctuation can be displayed as a                      *2  If a terminal service is used, then LabSolutions software does not need to be installed on client PCs.
                                                               graph for the entire analysis time, as either intensity                  *3  If an iPad is used, then XenApp from Citrix must be installed.
                                                               or intensity ratio with respect to a reference sample.                   Adding a LabSolutions  DB/CS connection kit (optional) enables compliance with electronic record-
                                                                                                                                                            ™
                                                               This helps quickly identify complications that occur                     keeping and electronic signature regulations, such as requirements specified in FDA 21 CFR Part 11.
                                                               due to sample matrix effects.
                                                                                                                                        Select either a standalone (LabSolutions DB) or networked (LabSolutions CS) system that is best for
                                                                                                                                        the given application. LabSolutions CS manages all analytical data in a database on a network server,
                                                                                                                                        so that the data can be loaded and postrun analysis can be performed on any computer connected to
                                                                                                                                        the network.
                                                                                                                                        Note: An additional software license is required for loading data onto a computer not connected to
                                                                                                                                        an ICPMS-2040/2050 Series system.
                                                               LabSolutions  ICPMS TRM (Optional)
                                                                            ™
                                                               Shimadzu LC-ICP-MS systems combined with LabSolu-
                                                               tions ICPMS TRM software can be used to speciate                         Software Required for Connecting to LabSolutions
                                                               arsenic, mercury, and other elements. The software
                                                               controls and configures both LC and ICPMS systems                                       Name                     P/N                       Remarks
                                                               in one simple platform.
                                                                                                                                          LabSolutions DB Connection Kit for ICPMS  211-49204-92  Standalone system
                                                                                                                                          LabSolutions CS Connection Kit for ICPMS  211-49241-92  Network system
                                                                                                                                          Second License for LabSolutions ICPMS  211-49245-91  Required for installing LabSolutions ICPMS on a
                                                                                                                                                                                          computer other than the control computer