Page 10 - Shimadzu’s Solutions for Impurities Analysis
P. 10

FDA Regulations on
                             Quantitation of Ultra-trace Impurities
       Genotoxic Impurities
           LCMS-2020



            ˙  Quantitation of Ultra-trace Organic Impurities Using an
              Ultra-Fast LC/MS System with Prominence UFLC and LCMS-2020

            Organic impurities in pharmaceutical products may derive   during the pharmaceutical production process, and stability
            from the ingredients, substances generated during   testing, "Genotoxic and Carcinogenic Impurities in Drug
            formulation, or substances decomposed during storage. A   Substances and Products: Recommended Approaches."
            mass spectrometer offering general detection and specific   The three "UF" (Ultra-Fast) features of the Shimadzu
            analysis is effective for the comprehensive and efficient   Ultra-Fast LC/MS system with Prominence UFLC and
            quantitation of ultra-trace impurities specified in the FDA   LCMS-2020 provide ultra-fast analysis of ultra-trace
            draft guidance on testing pharmaceutical ingredients, testing   impurities.
    FDA Regulations on
  Genotoxic Impurities

            ˙  The Prominence UFLC and LCMS-2020 Realize Ultra-Fast
              Analysis

              Ultra-Fast LC/MS system with Prominence UFLC and LCMS-2020
            ɾ
              ensures faster and more accurate HPLC analysis and improves
              productivity in your laboratories.
                                                                         ESI probe
              The three “UF” technologies: “UFswitching” for fast polarity
            ɾ
              switching, “UFscanning” for fast scanning and “UFsensitivity”
              for unsurpassed sensitivity and reproducibility utilizing newly
              designed ion optics ensure the capture of sharp peaks
  Residual Solvents
    FDA Regulations on
              generated by ultra-fast LC.
            ɾ
              The detection of ultra-trace impurities over a wide
              concentration range demands not only high sensitivity but also
              a wide dynamic range. The newly developed LCMS-2020 ion
                              ®
              optical system, Qarray , achieves superior sensitivity,
              reproducibility, and linearity.                                     Corona needle
              An extensive range of ionization methods is required to handle
            ɾ
              diverse impurities having different characteristics such as
                                                                              DUIS-2020 Concept Diagram
              oil-soluble and water-soluble compounds. The DUIS-2020 Dual
              Ion Source is one of the LCMS-2020's ionization methods. It
              combines ESI and APCI methods, ensuring that even impurities
              with significantly different polarities are not missed.
    FDA Regulations on
  Inorganic Impurities














                   LCMS-2020                                                   LabSolutions LCMS  Ver. 5
                   Ultra Fast Liquid Chromatograph Mass Spectrometer           LCMS-2020 Workstation