Page 32 - Application Notebook - Solution for Food Safety
P. 32

C146-E306











                    For LabSolutions Version 5.82 and Later

                   LC/MS/MS Method Package


                   for Residual Pesticides Ver. 2




                   ・   W orld’ s largest compound panel (646 pesticides in a
                      W
                      World’s largest compound panel (646 pesticides in a
                       orld’
                           s largest compound panel (646 pesticides in a
                      single method)
                      single method)
                      single method)
                   ・  Ultra-high-speed method, with detection in 10.5 minutes
                      Ultra-high-speed method, with detection in 10.5 minutes
                      Ultra-high-speed method, with detection in 10.5 minutes
                   ・   Ultra-high-speed detection delivers robust and reproducible
                      Ultra-high-speed detection delivers robust and reproducible
                      Ultra-high-speed detection delivers robust and reproducible
                      data quality for extended pesticide programs
                      data quality for extended pesticide programs
                      data quality for extended pesticide programs
                   ・   Pretreatment program to improve the shape of peaks for
                      Pretreatment program to improve the shape of peaks for
                      Pretreatment program to improve the shape of peaks for
                      polar pesticides
                      polar pesticides
                      polar pesticides
                   ・  Excellent data stability in combination with the
                      Excellent data stability in combination with the
                      Excellent data stability in combination with the
                      LCMS-8000 series
                      LCMS-8000 series
                      LCMS-8000 series
                                                                                                                LCMS-8060
                    Pesticide Screening Analysis for 646 Pesticides in 10.5 Minutes
                    Using this method package in combination with the   10 6      • Three MRM transitions for over 99% targeted pesticides (1,919 transitions in total)
                                                                   2.00           • A class-leading polarity switching time of 5 msec
                    LCMS-8050/8060 enables performing a pesticide analysis of
                    646 pesticides in 10.5 minutes.                1.75
                    Since the LCMS-8050/8060 have a rapid polarity switching time   1.50
                    of 5 msec, a single multi-residue LC/MS/MS method supports
                    the analysis of 612 pesticides in positive ion mode and 34   1.25
                    compounds in negative ion mode (Three MRM transitions for
                                                                   1.00
                    over 99% targeted pesticides, resulting in 1,919 transitions in
                    total).                                        0.75
                                                                   0.50
                                                                   0.25
                    MRM Chromatograms for 646 Pesticides Spiked into a Mint Extract at 0.01 mg/kg
                                                                    0
                                                                     0.0  1.0  2.0  3.0  4.0  5.0  6.0  7.0  8.0  9.0  10.0  min
                    Maintains High Data Quality Even with High-Speed Analysis  3.00  x10 6
                                                                                   • 25 pesticides eluting over a 9 time window  75 msec (16%)
                    The LCMS-8050/8060 delivers exceptional sensitivity and enhanced capability in   2.75   • Peak area variation for 25 components  10 msec (2%)
                                                                                      (%RSD, n = 6): 1.1-5.9 %RSD
                    pesticide screening. By developing unique technologies for fast data acquisition,   2.50
                    the LCMS-8050/8060 systems create new opportunities for high data density   2.25       Loop Time: 460 msec
                                                                                                              375 msec
                    analysis and expanded pesticide screening programs. For example, the peak area   2.00      (82%)
                    variation for 25 pesticides eluting over a nine-second time window (6.45-6.60   1.75    Polarity Switching Time
                    minutes) spiked into a mint matrix extract at the reporting limit of 0.01mg/kg          Pause Time
                                                                               1.50                         Dwell Time
                    varied between 1.1-5.9% (%RSD; n=6).
                                                                               1.25
                                                                               1.00
                                                                               0.75
                       MRM Chromatograms for 25 Components Detected with Retention Times of 6.45 to 6.60 Minutes  0.50
                                         (Three MRM Events Per Compound, One Polarity Switching) and  0.25
                         Ratio of Dwell Time (green), Pause Time (red) and Polarity Switching Time (blue) in 460 msec of  0.00
                                    Loop Time When 25 Pesticides are Simultaneously Monitored (Top right)  6.25  6.30   6.35   6.40   6.45   6.50   6.55   6.60   6.65   6.70   6.75   min
   27   28   29   30   31   32   33   34   35   36   37