Page 30 - Oligonucleotide Therapeutics Solution Guide
P. 30

Others


                     TORAST-H Series                                   This is a series of high-end consumables that Shimadzu GLC has
                                                                       evaluated and verified using the latest technology.



                     Original Low Adsorption Vial                                                                                       Original Low Adsorption Polypropylene Vial                                                         Modification

                     TORAST-H Glass Vial                                                                                                TORAST-H Bio Vial                                                                                    Target selection






                                 benefits

                       •   Minimized adsorption of bases, acids and neutrals                                                                         benefits
                       •   Two sizes are available (1.5 mL and 150 µL)                                                                                                                                                                     Unprotected  Excision
                       •   Superior Quality Control (Comes with quality certicates for                                                     •   Easy-to-use, user-friendly design                                                               Oligomer synthesis
                         lot management)





                     Low Adsorption for Long-term Storage                                                                               Adsorption Test Using Trypsin Digestion Products of Myoglobin (approx. 1.9 pmol/mL)

                     When a sample is stored in a general vial for a long time, the sample may adsorb into the surface of the vial, causing the reproducibility to be poor.   The results confirmed the phenomenon that highly polar peptides with retention times detected between approx. 7 and 8 minutes mostly adsorb to glass
                     The TORAST-H Glass Vial contains low adsorption characteristics that makes it excellent for long term sample storage.  vials, whereas highly hydrophobic peptides with retention times detected between approx. 12 and 16 minutes mostly adsorb to polypropylene (PP) vials.  Purification






                                                                       TORAST-H-
                                                                       Glass Vial
                                                                       Glass Vial A

                                                                       Glass Vial B

                                                                       Glass Vial C                                                                                                                                                        Quality Control   Characteristic analysis





                     *  The area value at 0 h of polypropylene (PP) vial (control) was regarded as 100%, and each area value was compared.
                     The recovery rate of PP vials after 3 months was 89%, which was lower than that of TORAST-H glass vials.
                                                                                                                                        Exterior Design that Enables Using Vials Directly for Flash Centrifugation

                                                                                                                                                                          Before        Centrifuge         After                           DDS
                           Product Name        Specification  Cap      Slit    Volume    Qty.        P/N                                                                                                                                     Pharmacokinetics
                                                                                                                                                                   Droplets
                                          glass, clear, label and filling lines  -                370-04300-01                                                    Sample loss
                                          (wide open 9-425)            +                          370-04300-02
                                                                               1.5 mL
                                          glass, amber, label and filling lines  -                370-04300-03                                                Air entrapment
                      TORAST-H Glass Vial  (wide open 9-425)           +                          370-04300-04                                           Prevents specified injection
                      (PTFE, Including vials, caps and
                      septum, cetification of inspection)  glass, clear, label and filling lines  Screw, Black  -  100 pcs. / pack  370-04301-01
                                          (wide open 9-425)            +                          370-04301-02
                                                                               150 µL                                                          Product Name      Specification    Slit      Volume       Qty.          P/N
                                          glass, amber, label and filling lines  -                370-04301-03                                                                                                                             Other
                                          (wide open 9-425)            +                          370-04301-04                            TORAST-H Bio Vial        PP Vial        Yes       300 µL       100        370-04350-00
                      Screw Cap for       PTFE / silicone septum       -                          370-04310-01                                    If using a Shimadzu i-Series LC system, use the special vial detection plate (P/N: 228-51891-03) shown to the right..
                      TORAST-H Glass Vial  (wide open 9-425)           +        -                 370-04310-02



        30                                                                                                                                                                                                                                  31
                                                                                                            index                                                                                                                  index