Page 31 - Oligonucleotide Therapeutics Solution Guide
P. 31

Others


 TORAST-H Series  This is a series of high-end consumables that Shimadzu GLC has
 evaluated and verified using the latest technology.



 Original Low Adsorption Vial  Original Low Adsorption Polypropylene Vial                                        Modification

 TORAST-H Glass Vial  TORAST-H Bio Vial                                                                            Target selection






 benefits

 •   Minimized adsorption of bases, acids and neutrals  benefits
 •   Two sizes are available (1.5 mL and 150 µL)                                                                 Unprotected  Excision
 •   Superior Quality Control (Comes with quality certicates for   •   Easy-to-use, user-friendly design             Oligomer synthesis
 lot management)





 Low Adsorption for Long-term Storage  Adsorption Test Using Trypsin Digestion Products of Myoglobin (approx. 1.9 pmol/mL)

 When a sample is stored in a general vial for a long time, the sample may adsorb into the surface of the vial, causing the reproducibility to be poor.   The results confirmed the phenomenon that highly polar peptides with retention times detected between approx. 7 and 8 minutes mostly adsorb to glass
 The TORAST-H Glass Vial contains low adsorption characteristics that makes it excellent for long term sample storage.  vials, whereas highly hydrophobic peptides with retention times detected between approx. 12 and 16 minutes mostly adsorb to polypropylene (PP) vials.  Purification






 TORAST-H-
 Glass Vial
 Glass Vial A

 Glass Vial B

 Glass Vial C                                                                                                    Quality Control   Characteristic analysis





 *  The area value at 0 h of polypropylene (PP) vial (control) was regarded as 100%, and each area value was compared.
 The recovery rate of PP vials after 3 months was 89%, which was lower than that of TORAST-H glass vials.
               Exterior Design that Enables Using Vials Directly for Flash Centrifugation

                                                Before        Centrifuge         After                           DDS
 Product Name  Specification  Cap  Slit  Volume  Qty.  P/N                                                         Pharmacokinetics
                                         Droplets
 glass, clear, label and filling lines  -  370-04300-01  Sample loss
 (wide open 9-425)  +  370-04300-02
 1.5 mL
 glass, amber, label and filling lines  -  370-04300-03  Air entrapment
 TORAST-H Glass Vial  (wide open 9-425)  +  370-04300-04  Prevents specified injection
 (PTFE, Including vials, caps and
 septum, cetification of inspection)  glass, clear, label and filling lines  Screw, Black  -  100 pcs. / pack  370-04301-01
 (wide open 9-425)  +  370-04301-02
 150 µL              Product Name      Specification    Slit       Volume      Qty.          P/N
 glass, amber, label and filling lines  -  370-04301-03                                                          Other
 (wide open 9-425)  +  370-04301-04  TORAST-H Bio Vial  PP Vial  Yes  300 µL   100        370-04350-00
 Screw Cap for   PTFE / silicone septum  -  370-04310-01  If using a Shimadzu i-Series LC system, use the special vial detection plate (P/N: 228-51891-03) shown to the right..
 TORAST-H Glass Vial  (wide open 9-425)  +  -  370-04310-02



 30                                                                                                               31
 index                                                                                                   index
   26   27   28   29   30   31   32   33   34