Page 9 - Material Characterizations
P. 9

Optical Emission Spectrometer     OES








































          PDA-8000







          Key Features and Capabilities                         Time Resolution Pulse Distribution Analysis (PDA)
                                                                Photometry
          • Top-tier spectrometer
          • Paschen-Runge Spectrometer with 1000mm focal length  • The discharge conditions to obtain the optimal measurement
             providing high resolution measurements                sensitivity differ for each spectral line
          • Time-Resolution PDA Photometry (Patented Technique)  • The table below compares the Background Equivalent
          • Temperature-controlled chamber for spectrometer        Concentration (BEC) values for a conventional method and
          • Vacuum spectrometer enhances sensitivity and           the PDA-series
             low running cost
          • Novel excitation unit with real-time energy monitoring       Element          C      P      S      B
          • Ultra-trace Analysis of high purity materials
          • Feature-rich software with intuitive interface       Conventional Method (ppm)  160  150   100    80
          • Energy efficient design with “Eco-friendly” label        PDA Method (ppm)     80     75    50     40





                                                                                                 Constant Regulative Spark (CRS)
                                                            Photomultiplier    Discharge
                                                            Tube
                                                                               Defect

                                                  Exit Slit  Toroidal Mirror  Realtime Energy Monitoring  Conventional Arc-Like Discharge
         Newly Designed Spectrometer  A Novel Excitation Unit  Light Receptor  Constant Monitoring of  Ultra Trace Analysis of
          Achieves Higher Stability                 Condensing System  the Discharge Status    High Purity Materials

          Wavelength Range | •120 to 550 nm (ferrous metals)   •120 to 700 nm (non-ferrous metals)

          Metal Base          | • Fe / Al / Cu / Zn / Pb / Sn / Mg / Ni / Ti etc   • Single or multi-element base


                                                                                                          Excellence in Science  13