Page 16 - LifeScience Solution for FNIRS
P. 16

For Research Use Only. Not for use in diagnostic procedures.

            Investigating Inner Speech                                                                                                                                                                                                          Light to Measure Brain Function  Principle of Using Near Infrared







               Data                                                                                                                                                                                                                             Imaging  Optical Brain-Function


               NIRS signals from the head surface were used to estimate the time when the subject made inner speech without vocalization and to      Inner Speech  Outer Speech           The large changes in the electromyograms of the left and right
               guess a number between 1 and 5 reechoes by the subject in his/her mind.                                                                                                    platysma and temporal muscles that occur under outer speech
               Two separations between transmitter and receiver optical fiber probes (7 and 18 mm spacing), as shown in Fig. 1, were used to                                              conditions when a tongue twister is recited out loud indicate
               measure the NIRS signals across the entire left and right forehead. Simultaneous measurements of the scalp blood flow and      18 mm                                       activity in these muscles.
               electromyograms were performed to evaluate the effects of skin blood flow and muscle blood flow on NIRS signals.                                                           Increased skin blood flow measured by the Doppler skin blood   bilitation  Neuroreha-
                                                                                                                                                                                          flowmeter can be observed throughout the outer speech period.
                                                                                                                                                                                          NIRS measurements at the short probe spacing (7 mm) also
                                                                                            Photo-transmitter probe
                                                                                                                                               7 mm                                       indicate that Oxy-Hb and Total-Hb concentrations increase
                                                                                            Photo-receiver probe                                                                          continuously during the outer speech period (Fig. 3).
                                                                                                                                                                                          Conversely, no changes in the platysma and temporal   fNIRS and fMRI  Comparison of
                                                                                            Measurement channels                        Skin Blood Flowmeter
                                                                                                                                                                                          electromyograms are apparent with inner speech. This provides
                                                                                            Doppler
                                                                                                                                                                                          objective evidence that no vocalization occurs. The short
                                                                                            Platysma EMG                                        EMG                                       transient increases (interval approx. 5 sec, rising latency tune
                                                                                                                                                                                          approx. 3 sec) were detected by the Doppler skin blood
                                                                                            Temporal EMG
                                                                                                                                                     0    60       0    60  (sec)         flowmeter, although not as large as for outer speech and no   Motor Control  Brain Activity during
                                                                                                                                          Fig. 3  NIRS Waveforms, Skin Blood Flow Fluctuations,  continuous increase in blood flow was apparent (Fig. 3).
                                                                                                                                                             Electromyogram during Inner Speech and Outer Speech
                                                                                                                                                  Inner Speech (n = 16)  Outer Speech (n = 16)   Resting (n = 64)  The NIRS signals in the representative channel near Broca's area
                                                                                                                                                                                          and the averaged Doppler skin blood flow signals yielded similar
                                                                                                                                                                                          results (Fig. 4).                                     Measurement with EEG  Simultaneous
                                                                                                                                              18 mm
                                                                                                                                                                                          These results indicate that it is necessary to consider at least the
                                                                                                                                                                                          skin blood flow and muscle activity effects when interpreting the
                                                                                                                                                                             Oxy-Hb       NIRS signals during NIRS measurement tasks involving
                                                                                                                                                                             Deoxy-Hb     vocalization. The possibility remains that even during inner
                                                    Fig. 1  Multiresolution Analysis                                                                                         Total-Hb
                                                                                                                                               7 mm                                       speech involving no vocalization, skin blood flow fluctuations   Analysis Method  NIRS Signal
                                                                                                                                                                                          due to autonomous nervous system activity may affect the NIRS
               The probe channel positions are projected onto the MRI brain surface image. Probes are placed at 18 mm spacing in a 3×5
               arrangement over the entire left and right forehead (44 ch), and at 7 mm spacing on the left forehead (1 ch).                                                              signals. Consequently, a method to eliminate the effects of skin
                                                                                                                                                                                          blood flow and muscle activity on NIRS signals is particularly
               Fig. 2 shows typical NIRS signals when the subject recites a tongue twister internally without vocalization when the chosen number is                                      important when performing measurements to measure brain
               read. Multiple channels containing Broca's area (representative channel 11) show a transient increase in Oxy-Hb and Total-Hb   Skin Blood Flowmeter                        functions.
               concentrations when the chosen number 3 is read.                                                                                                                                                                                 Inner Speech  Investigating

                                                                                                                                          Fig. 4  NIRS and Skin Blood Flow Average Waveforms during Inner
                                                                                                                                                     Speech, Outer Speech, and Resting
                                                                                                                                         Shadow width ±1S.E. Resting shows the average waveform when
                                                                                                                                         a number different from the pre-chosen number is read.                                                 Functions  Language Processing
                                                                                                                                         NIRS measurements make it possible to estimate the time when the subject recited a tongue twister internally without vocalization
                                                                                                                                         and further estimate the number pre-chosen by the subject with a certain degree of accuracy. It was confirmed that the NIRS
                                                                                                                                         measurements with 7 mm probe spacing produced data reflecting the skin blood flow fluctuations and that the NIRS measurements
                                                                                                                                         with 18 mm probe spacing produced data reflecting brain blood flow fluctuations independent of the skin blood flow fluctuations.
                                                                                                                                         The ability to distinguish between brain activity-derived NIRS signals and skin blood flow signals during inner speech promises future   Research  Mental Disorder
                                                                                                                                         applications of NIRS measurements to BMI.

                             Fig. 2  Typical NIRS Waveforms Blood Flow Fluctuations in Broca's Area (representative channel 11).
                                                                                                                                         (Data supplied by: Shigeru Kitazawa, MD, PhD, Juntendo University School of Medicine
               NIRS waveform results from four subjects were visually evaluated by five researchers. They were able to determine the number chosen   Reference: Iwano, T., Takahashi, T., Takigawa, J., Kawagoe, R., Shibuya, S., Kitazawa, S. (2010)  Shimadzu fNIRS   Key References Regarding
                                                                                                                                                          "Detection of inner speech using near infrared spectroscopy", Shimadzu Review, Vol. 66, No. 3, 4
               by the subject with 73 % accuracy.




      16                                                                                                                                                                                                                                       17
   11   12   13   14   15   16   17   18   19   20   21