Page 16 - Pharmaceutical- Guide to Biopharmaceutical
P. 16

Culture


                     Cell Culture Media Analysis Platform                                                                               C2MAP Cell Culture Media Analysis Platform System





                                Automates Processes from Pretreatment to LC/MS/MS                                                                          benefits

                                   Measurement for Culture Supernatant Analysis                                                                                                                                                              Cell Line Optimization
                                                                                                 click here                                     •    Automating culture supernatant analysis processes from pretreatment to LC/MS
                                                                                                                                                  measurement ensures anyone can acquire high-quality data.
                     Operating Principle and Features
                                                                                                                                                •   Dedicated control software makes it easy to link samples to measurement results.
                     The C2MAP-2030 is an automatic pretreatment system for removing   TRENDS software included with the C2MAP-2030 system.     •   The system can be operated using only the modules necessary for automatic
                     proteins from culture supernatants by suction filtering the proteins   By connecting the C2MAP automatic pretreatment system to the LC-
                     precipitated by adding an organic solvent. Deproteinized culture   MS/MS system, samples can be analyzed seamlessly. Because sample   pretreatment, while the LC-MS/MS system is also used for a separate analysis.     Culture
                     supernatant samples are automatically transferred to the HPLC   information is linked to measurement data files, the C2MAP system
                     autosampler, where they are dispensed onto a microtiter plate (MTP)   can also reduce human error, such as from loading the wrong sample.
                     for storage. Those samples are automatically supplied for LC/MS/MS   Manual methods can cause variations in data quality, but automated
                     measurement, where 95 components are analyzed simultaneously   equipment helps ensure any operator can acquire data with good
                     using the Cell Culture Profiling Method (equivalent to Ver. 1). After   repeatability (Fig. 2). Automation can also reduce operational hours (Fig.
                     peak integration, time-series data for each component can be   3).
                     visualized easily (Fig. 1) by loading the data file into the C2MAP



                           Automatic Pretreatment  Autosampler     LCMS-8050/-8060     C2MAP TRENDS                                                                                                                                          Purification
                                  System           SIL-30AC       Cell Culture Profiling
                               C2MAP-2030                        (includes methods equivalent to Ver. 1)








                              • Organic solvent                                                                                                                                                                                              Characterization
                                precipitation and   • Automatic sample dilution  • LC/MS/MS measurement  • Visualization of
                                suction filtration  • Dispensing into MTP plates          temporal changes
                              • Sample transferring               • Peak integration     in each component
                             Automated process steps
                                                      Fig. 1   Analysis Process Flow with C2MAP System

                                Area Reproducibility for Caffeine                                                                                                                                                                            Quality Control

                                                                                    Total

                                                                                                                                        Specifications
                                                                        C2MAP system      70 min                                         Instrument            C2MAP-2030
                                                                                                                                         LC unit               Nexera X2 (CBM-20A, LC-30AD, CTO-20AC, SIL-30AC, MR 20 μL mixer, and other units)
                                                                      Conventional                                                       MS unit               LCMS-8050/-8060
                                                                      Method (Manual            475 min                                  Required sample quantities  400 to 500 µL (or 100 to 250 µL using optional rack)
                                                                      Operations)                                                                                                                                                            Pharmacokinetics
                                                                                                                                         Processing time       10.8 min per sample (17 min per sample for LC/MS measurements)
                                  C2MAP  Operator A  Operator B  Operator C
                                                                                                                                         Pretreatment processes  Add internal standard, sample, and organic solvent, mix, filter by suction filtration, and transfer
                                 Fig. 2   Comparison of Analysis Repeatability  Fig. 3   Comparison of Operator Labor Hours                                    sample after processing
                                                                                                                                         Pretreatment methods  Batch mode     Starts LC/MS measurement after pretreatment is finished for all samples.
                                                                   Conclusion                                                                                  Sequential mode  Each sample processed successively in parallel.
                                                                                                                                                               Pretreatment mode  All samples are pretreated only.
                                                                   The C2MAP system can automate the deproteinization process for up                                                                                                         Others
                                                                   to 65 culture supernatant samples.                                    Max. number of samples  65 (or 64 using the sequential mode)
                                                                   By linking it to an LC-MS system, the entire process from pretreatment   External dimensions  W 670 × D 700 × H 1,190 mm (C2MAP-2030 only)
                                                                   to LC/MS/MS measurement can be executed seamlessly.
                                                                                                                                         Weight                185 kg (C2MAP-2030 only)



        16                                                                                                                                                                                                                                  17
                                                                                                            index                                                                                                                  index
   11   12   13   14   15   16   17   18   19   20   21