Page 30 - Clinical-Medical Solution for Clinical Chemistry
P. 30

Application     AD-0135
     News


           Conclusions                                       References

          A fast MRM-based method for quantitation of five β-lactam  1. Sibhghatulla Shaikh, Jamale Fatima, Shazi Shakil, Syed Mohd.
          antibiotics tazobactam, cefepime, meropenem, ceftazidime  Danish Rizvi. 2015. 22(1), 90 - 101
          and piperacillin in human plasma was developed on LCMS-  2. Mohammad Amjad Kamal. Saudi J Biol Sci. S. K. Grebe, R. J.
          8060. A simple sample pre-treatment with protein crash by  Singh. Clin. Biochem. Rev. 2011. 32(1), 5 – 31
          organic solvent was applied and a small injection volume of  3. Berendsen, B. (2013). LC-MS residue analysis of antibiotics:
          2 µL was required due to the high sensitivity of the LCMS-  What selectivity is adequate?
          8060 employed. The method performance was evaluated  4. Deepti Bhandarkar, Rashi Kochhar, Shailendra Rane, Shruti
                                                                Raju, Shailesh Damale, Ajit Datar, Pratap Rasam and Jitendra
          on the linearity, accuracy, repeatability, recovery, matrix  Kelkar, Highly sensitive quantitative analysis of Amoxicillin and
          effect, specificity and limit of quantitation (LOQ). The  Clavulanic acid from plaama using LC/MS/MS, ASMS 2015,
          estimated LOQs of the method for the five antibiotics are in  Poster TP 280 (PO-CON1546E)
          the range from 0.7 ng/mL to 6.0 ng/mL with an injection  5.  Pieter Colin, Lies De Bock, Huybrecht Tjollyn, Koen Boussery,
          volume of 2 µL.                                       and Jan Van Bocxlaer, Talanta 103 (2013) 285-293.
                                                             6. Sebastiano Barco, Roberto Bandettini, Angelo Maffia, Gino
                                                                Tripodi, Elio Castagnola and Giuliana, J. Chemotherapy Vol 27
                                                                (2015) No. 6, 343-347.




                                                             Disclaimer: The data and instruments presented in this
                                                             Application News are intended for Research Use Only (RUO).
                                                             Not for use in diagnostic procedures.




























































      Application Development & Support Centre, SHIMADZU (Asia Pacific)   Copyright © 2016 SHIMADZU (Asia Pacific) Pte. Ltd.
      Pte. Ltd, 79 Science Park Drive, #02-01/08 Cintech IV, Singapore 118264,   All rights reserved. No part of this document may be reproduced in any form or by
      www.shimadzu.com.sg; Tel: +65-6778 6280 Fax: +65-6778 2050   any means without permission in writing from SHIMADZU (Asia Pacific) Pte. Ltd.