Page 12 - Shimadzu SolidSpec-3700i
P. 12

Optional Software                                                                                                         Guide to Selecting Accessories


            Optional software adds various data analysis functions to the spectral evaluation functionality in LabSolutions UV-Vis.   In order for UV-Vis and NIR spectrophotometers to perform their full functions, it is necessary to select the
            Pass/fail criteria can also be specified for data analysis results.                                                        appropriate accessories for the application field and sample properties. A wide variety of accessories are
                                                                                                                                      available to support a wide range of applications, from basic measurement such as transmission and
                                                                                                                                      relative/absolute reflection measurement, to multi-sample and micro-sample measurement. Please refer to the
            Color Calculation Software                                                                                                UV-VIS Series Accessories handbook (C101-E070) for details.
            (P/N 207-24528-91)                                                                                                          Solid Samples
                                                                                                                                       Samples        Measurement Method and Conditions                    Accessories
            This software is used to calculate the color value of measured substances based                                                                  Less than 3 mm thick  Standard Sample Compartment + Film Holder, Cell Type Sample Holder,
                                                                                                                                                                                   Glass/Film Holder for Standard Sample Compartment
            on measured spectra. It can also display color diagrams, such as by plotting                                                                     More than 3 mm thick  Integrating Sphere Attachment (ISR-2600, ISR-2600Plus, ISR-603)
            color coordinates in an XYZ color system or plotting CIELAB lightness index or                                                  Transmittance measurement  Requires a large integrating sphere  Integrating Sphere Attachment, 150 mm Dia. (ISR-1503, ISR-1503F)
            color coordinate values.                                                                                                                         (due to ISO compliance and other reasons).
                                                                                                                                                             Large sample size (over 100 mm square)  Large-Sample Compartment (MPC-2600A/603A or SolidSpec-3700i) Glass Sample Holder for MPC series/SolidSpec
                                                                                                                                                    Relative specular  Normal measurement  Specular Reflectance Measurement Attachment (5° incident angle)
            • It includes the major calculation parameters, such as the XYZ color system,                                                           reflectance
                                                                                                                                       Smooth       measurement  Large sample size (over 100 mm square)  SolidSpec-3700i + Large Specular Reflectance Measurement Attachment (5° incident angle)
              CIELAB, CIELUV, Munsell color system, mentalism, yellowness, whiteness, and                                              Surface                                     Absolute Specular Reflectance Attachment (ASR-3105) (Requires a Large-Sample Compartment and
                                                                                                                                       Samples*              5° incident angle measurement  BIS-3100/3700/603 Sample Base Plate Integrating Sphere Set separately).
              color difference.                                                                                                                     Absolute specular  12°/30°/45° incident angle  Absolute Specular Reflectance Attachment (ASR-3112, ASR-3130, ASR-3145) (Requires a Large-Sample
            • Colors relevant to JIS and ASTM standards can be calculated.*                                                                 Reflectance  reflectance  measurement    Compartment, BIS-3100/3700/603 Sample Base Plate Integrating Sphere Set, and polarizer assembly separately.)
                                                                                                                                                    measurement
                                                                                                                                            measurement
            • Measurement illuminants, viewing angle, and other parameters can be                                                                            Variable incident angle measurement  Variable Angle Measurement Unit (Requires large-sample compartment and polarizer assembly separately.)
              specified for the various types of calculation.                                                                                        Relative diffuse  Normal measurement  Integrating Sphere Attachment (ISR-2600, ISR-2600Plus, ISR-603)
                                                                                                                                                    reflectance  Requires a large integrating sphere  Integrating Sphere Attachment, 150 mm Dia. (ISR-1503, ISR-1503F)
                                                                                                                                                    measurement  (due to ISO compliance and other reasons).
            Film Thickness Calculation Software                                                                                                              Large sample size (over 100 mm square)  Large-Sample Compartment (MPC-2600A/603A, or SolidSpec-3700i)
                                                                                                                                                                                   Integrating Sphere Attachment (ISR-2600, ISR-2600Plus, ISR-603)
                                                                                                                                                             Normal measurement
            (P/N 207-24528-91)                                                                                                              Transmittance measurement  Requires a large integrating sphere  Integrating Sphere Attachment, 150 mm Dia. (ISR-1503, ISR-1503F)
                                                                                                                                                             (due to ISO compliance and other reasons).
            This software is used to calculate film thickness from measured spectra based                                               Rough                 Large sample size (over 100 mm square)  Large-Sample Compartment (MPC-2600A/603A, or SolidSpec-3700i)
            on the interference interval method. (Calculating the film thickness requires                                               Surface      Relative diffuse  Normal measurement  Integrating Sphere Attachment (ISR-2600, ISR-2600Plus, ISR-603)
                                                                                                                                       Sample**              Requires a large integrating sphere
            entering the refractive index of the sample.)                                                                                   Reflectance  reflectance  (due to ISO compliance and other reasons).  Integrating Sphere Attachment, 150 mm Dia. (ISR-1503, ISR-1503F)
                                                                                                                                                    measurement
                                                                                                                                            measurement      Large sample size (over 100 mm square)  Large-Sample Compartment (MPC-2600A/603A, or SolidSpec-3700i)
            • The interference interval method calculates the film thickness based on                                                                Absolute diffuse reflectance measurement  Consult your Shimadzu representative.
                                                                                                                                                                                   (Depends on the sample. A method using conversion from the mirror reflectance, for instance, is available.)
               the interval between interference peaks (or valleys). The incident angle                                                Large sample size (over 100 mm square)      Large-Sample Compartment (MPC-2600A/603A, or SolidSpec-3700i)
               and wavelength range for film thickness calculations and peak (or valley)                                                Small sample size (below 5 mm square)       Micro Sample Holder + Micro Beam Lens Unit
               detection parameters can be specified.                                                                                  * Metals with a mirror-finished surface, mirrors, transparent acrylic and films, etc.
                                                                                                                                      ** Paper, cloth, plastics, semi-transparent films, etc.
                                                                                                                                      For color measurement, the Color Analysis Software or LabSolutions UV-Vis Color Calculation Software is required separately. For film thickness measurement, the Film Thickness Calculation
                                                                                                                                      Software is required separately.
            Solar Radiation Calculation Software                                                                                        Liquid Samples
            (P/N 207-25806-91)                                                                                                          Samples              Measurement Method and Conditions                   Accessories
                                                                                                                                              Sample volume: 2.5 mL min.                       Standard Sample Compartment + 10 mm Cell
            This software is used to calculate solar transmittance/reflectance based on measured                                                                   1 mL min.                    Semi-Micro Cell + Micro Cell Holder with Mask
            spectra.                                                                                                                                              500  L min.                  Micro Cell + Micro Cell Holder with Mask
                                                                                                                                              Micro-volume measurement
                                                                                                                                                                  50  L min.                   Super-micro Cell + Super-micro Cell Holder
            • It includes major calculation parameters, such as visible light transmittance/                                                                      For automatically measuring samples in multiple cells  MMC-1600 8/16 Series Micro Multi-Cell Holders and Cells
                                                                                                                                              Samples with high absorbance, but that are difficult to dilute (short optical path measurement)  Short-Path Cell (1, 2, 5 mm) + Spacer for Short-Path Cell
              reflectance, total light transmittance/reflectance, near-infrared reflectance,
                                                                                                                                              Samples with low absorbance, but that are difficult to concentrate (long optical path measurement)  Long-Path Cell (20, 30, 50, 100 mm) + Long-Path Rectangular Cell Holder
              ultraviolet ray transmittance, CIE damage factor, and skin damage factor.
                                                                                                                                                        Normal measurement                     Multi-Cell Sample Compartment (sample volume: 2.5 mL min.)
            • Parameters relevant to JIS, ISO, and GB/T standards can be calculated.*                                                         For automatically  Small sample volumes (50  L min.)  MMC-1600 8/16 Series Micro Multi-Cell Holders and Cells
                                                                                                                                              measuring samples
                                                                                                                                       Transparent  in multiple cells  Requires temperature control  CPS-100 Six-Cell Thermoelectrically Temperature-Controlled Cell Positioner
                                                                                                                                       Samples                                                 (sample volume: 2.5 mL min.)
                                                                                                                                              For temperature-  Temperature-controlled with water circulation  Constant-Temperature Cell Holder + NTT-2200P Constant-Temperature Water Circulator
            UPF Calculation Software                                                                                                          controlled  Thermoelectrically  Normal measurement  TCC-100 Thermoelectrically Temperature-Controlled Cell Holder
                                                                                                                                              measurements
            (P/N 207-25806-91)                                                                                                                (constant-  temperature  For automatically measuring samples in multiple cells  CPS-100 Six-Cell Thermoelectrically Temperature-Controlled Cell Positioner
                                                                                                                                              temperature
                                                                                                                                                        controlled
                                                                                                                                              measurement)        Tm analysis or variable temperature measurement  S-1700 Thermoelectric Single Cell Holder
            This software is used to calculate ultraviolet protection factor (UPF) values                                                               Requires temperature control (constant-temperature water circulation)  160C Sipper Unit + NTT-2200P
                                                                                                                                              Automatically  Temperature control not necessary  160L/160T/160U Sipper Unit (Select type based on liquid volume.)
            based on measured spectra.                                                                                                        supplies sample
                                                                                                                                              to flow cells  Requires accurate  Requires temperature control  Syringe Sipper CN + NTT-2200P (Select flow cell based on liquid volume.)
                                                                                                                                              (automatic analysis) control of  (constant-temperature water circulation)
            • It can calculate UPF, UVA, UVB, and ultraviolet protection values for either                                                              aspiration volume. Temperature control not necessary  Syringe Sipper N (Select flow cell based on liquid volume)
              UVA and UVB.                                                                                                                    For automating measurement of multiple samples   Sipper Unit or Syringe Sipper + ASC-5 Auto Sample Changer
            • Values relevant to JIS, DIN, BS, AATCC, AS/NZAA, or GB/T standards can be                                                       Absorption measurement  Wavelength range: 240 nm min.  Integrating Sphere Attachment (ISR-2600, ISR-2600Plus, ISR-603)
                                                                                                                                              of suspension samples  For measuring UV region above 190 nm  SolidSpec-3700i DUV
              calculated.*                                                                                                             Suspension
                                                                                                                                       Samples                    Light transmitted light turbidity measurement  10/50 mm Cell + Long-Path Rectangular Cell Holder
                                                                                                                                              Turbidity measurement  (commonly used measurement method)  (Optical path length of cell depends on test method.)
            * For more details about applicable standards, contact Shimadzu.                                                                                      Integrating sphere turbidity measurement  Integrating Sphere Attachment (ISR-2600, ISR-2600Plus, ISR-603)
                                                                                                                                                                                                      SolidSpec-3700i/3700i DUV
      12                                                                                                                                                                                                                    UV-VIS-NIR Spectrophotometer  13