Page 15 - Shimadzu SolidSpec-3700i
P. 15
Accessories
Absolute Reflectance Variable Angle Measurement Large Polarizer Assy / Accessories Dedicated for SolidSpec-3700i DUV
Attachments Unit for SolidSpec-3700i Polarizer Assy
(P/N 207-23470-41) Purge Box MC-3BS Constant-Flowrate Thermal
(P/N 206-21788-58) Controller
(P/N 206-28212-91)
This attachment enables absolute specular This device enables absolute reflectance These enable control of polarization character- This unit is required for purging the direct detection unit with This controller controls nitrogen flowrate during nitrogen purging.
reflectance measurements of solid samples. measurements of solid samples, with the istics of incident light on samples. nitrogen. It includes a film holder and six-cell holder.
It is compatible with sample sizes from 20 to incident and reflection angles set to any angle.
150 mm square and up to 30 mm thick. Measurement wavelength range is 250 to P/N Type Wavelength range
Requires a sample stage and integrating 2500 nm. It is compatible with sample sizes 206-15694-40 Large type 250 to 2300 nm
sphere set separately. from 20 to 70 mm square and between 2 and 206-13236-41 Type I 400 to 800 nm Compatible Accessories When Direct Detection Unit Is Added
Type II
260 to 700 nm
206-13236-42
15 mm thick. The incident angle can be set 206-13236-40 Type III 260 to 2300 nm
P/N Incident Angle Wavelength range between 5 and 70 degrees.
206-16817-58 5° 300 to 2400 nm Direct Detection Units Film Holder Long-Path Rectangular Cell
206-16100-58 12° 300 to 2500 nm
206-15001-58 30° 300 to 2300 nm (P/N 206-20264-XX) (P/N 204-58909) Holder
206-15002-58 45° 300 to 2300 nm (P/N 204-23118-01)
Powdered Sample Holder Micro Sample Holder Large Specular Reflectance
(for Integrating Sphere) (P/N 206-28055-41) Attachment
(P/N206-89065-41) (5° incident angle)
(P/N 206-28055-41)
This unit enables measurements without This holder is used to hold films, filters, and This holds rectangular cells with an optical
using the integrating sphere normally used other items.It is compatible with sample sizes path length of 10, 20, 30, 50, 70, or 100 mm.
as the detector for SolidSpec systems. between a minimum W16 × H32 mm and
maximum W80 × H40 mm.
P/N Wavelength range Available Model
-51 190 to 3300 mm for SolidSpec -3700i
-52 165 to 3300 mm for SolidSpec -3700i DUV
This powdered sample holder is for This holds small samples against the integrat- This attachment enables relative specular
installation in an integrating sphere. ing sphere. reflectance measurements of the large samples.
It is compatible with sample sizes from 5 to 10 It is compatible with samples up to 470 mm Spacers for Short-Path Cells Super-micro Cell Holder Specular Reflectance Attachment
mm square and between 0.5 and 2 mm thick. wide, 560 mm tall, or 40 mm thick. (P/N 204-21473-XX) (P/N 206-14334) (5° incident angle)
(P/N 206-14046-58)
Optical path length of the cell
Automatic X–Y Stage
(P/N 206-20810-58)
This standard cell P/N Available cells This cell holder is for supermicro cells. This device enables specular reflectance
holder is required for -01 2 mm Volumes between 50 and 200 L can be measurements. The angle of incidence to the
short optical path cells. -02 5 mm measured, depending on the type of black sample is 5 degrees.
-03 1 mm cell used. It is compatible with sample sizes from 7 mm
in diameter up to 160 × 100 mm and up to
15 mm thick.
This accessory automatically measures multiple
points. It is compatible with samples up to
310 mm in diameter, 310 mm square, or 40 Various other accessories
mm thick.
Solid Samples Liquid Samples
SolidSpec-3700i/3700i DUV
14 UV-VIS-NIR Spectrophotometer 15