Page 14 - Shimadzu SolidSpec-3700i
P. 14

Accessories


            Absolute Reflectance               Variable Angle Measurement        Large Polarizer Assy /                                Accessories Dedicated for SolidSpec-3700i DUV
            Attachments                       Unit for SolidSpec-3700i          Polarizer Assy
                                              (P/N 207-23470-41)                                                                      Purge Box                                             MC-3BS Constant-Flowrate Thermal
                                                                                                                                      (P/N 206-21788-58)                                    Controller
                                                                                                                                                                                            (P/N 206-28212-91)







            This attachment enables absolute specular   This device enables absolute reflectance   These enable control of polarization character-  This unit is required for purging the direct detection unit with   This controller controls nitrogen flowrate during nitrogen purging.
            reflectance measurements of solid samples.   measurements of solid samples, with the   istics of incident light on samples.   nitrogen. It includes a film holder and six-cell holder.
            It is compatible with sample sizes from 20 to   incident and reflection angles set to any angle.
            150 mm square and up to 30 mm thick.   Measurement wavelength range is 250 to   P/N  Type  Wavelength range
            Requires a sample stage and integrating   2500 nm. It is compatible with sample sizes   206-15694-40  Large type  250 to 2300 nm
                                                                                             Type I
            sphere set separately.            from 20 to 70 mm square and between 2 and   206-13236-41  Type II  400 to 800 nm        Compatible Accessories When Direct Detection Unit Is Added
                                                                                                     260 to 700 nm
                                                                                  206-13236-42
                                              15 mm thick. The incident angle can be set   206-13236-40  Type III  260 to 2300 nm
                P/N     Incident Angle   Wavelength range  between 5 and 70 degrees.
              206-16817-58  5°    300 to 2400 nm                                                                                      Direct Detection Units            Film Holder                       Long-Path Rectangular Cell
              206-16100-58  12°   300 to 2500 nm
              206-15001-58  30°   300 to 2300 nm                                                                                      (P/N 206-20264-XX)                (P/N 204-58909)                   Holder
              206-15002-58  45°   300 to 2300 nm                                                                                                                                                          (P/N 204-23118-01)

            Powdered Sample Holder             Micro Sample Holder              Large Specular Reflectance
            (for Integrating Sphere)           (P/N 206-28055-41)               Attachment
            (P/N206-89065-41)                                                   (5° incident angle)
                                                                                (P/N 206-28055-41)
                                                                                                                                      This unit enables measurements without   This holder is used to hold films, filters, and   This holds rectangular cells with an optical
                                                                                                                                      using the integrating sphere normally used   other items.It is compatible with sample sizes   path length of 10, 20, 30, 50, 70, or 100 mm.
                                                                                                                                      as the detector for SolidSpec systems.   between a minimum W16 × H32 mm and
                                                                                                                                                                        maximum W80 × H40 mm.
                                                                                                                                       P/N   Wavelength range  Available Model
                                                                                                                                       -51  190 to 3300 mm  for SolidSpec -3700i
                                                                                                                                       -52  165 to 3300 mm  for SolidSpec -3700i DUV

            This powdered sample holder is for   This holds small samples against the integrat-  This attachment enables relative specular
            installation in an integrating sphere.  ing sphere.                 reflectance measurements of the large samples.
                                              It is compatible with sample sizes from 5 to 10   It is compatible with samples up to 470 mm   Spacers for Short-Path Cells  Super-micro Cell Holder        Specular Reflectance Attachment
                                              mm square and between 0.5 and 2 mm thick.  wide, 560 mm tall, or 40 mm thick.           (P/N 204-21473-XX)                (P/N 206-14334)                   (5° incident angle)
                                                                                                                                                                                                          (P/N 206-14046-58)
                                                                                                                                                 Optical path length of the cell
             Automatic X–Y Stage
            (P/N 206-20810-58)




                                                                                                                                      This standard cell   P/N  Available cells  This cell holder is for supermicro cells.  This device enables specular reflectance
                                                                                                                                      holder is required for   -01  2 mm  Volumes between 50 and 200  L can be   measurements. The angle of incidence to the
                                                                                                                                      short optical path cells.   -02  5 mm  measured, depending on the type of black   sample is 5 degrees.
                                                                                                                                                         -03   1 mm     cell used.                        It is compatible with sample sizes from 7 mm
                                                                                                                                                                                                          in diameter up to 160 × 100 mm and up to
                                                                                                                                                                                                          15 mm thick.
            This accessory automatically measures multiple
            points. It is compatible with samples up to
            310 mm in diameter, 310 mm square, or 40                                                                                                                                                            Various other accessories
            mm thick.
                                                                                                                                                                                                                 Solid Samples   Liquid Samples






                                                                                                                                                                                                     SolidSpec-3700i/3700i DUV
      14                                                                                                                                                                                                                    UV-VIS-NIR Spectrophotometer  15
   9   10   11   12   13   14   15   16