Page 8 - Shimadzu Nexera UC
P. 8

Unified speed of analysis, sensitivity, and resolution




                  Solutions provided by Nexera UC




                  Very fast separation speed due to the relatively low viscosity of supercritical fluid

                  Improved peak capacity and chromatographic resolution
                  Efficient separation of analogues and/or chiral compounds by high penetration mobile phase

                  Different separation mode leads to high sensitivity

                  Improved sensitivity resulting from split-less introduction into detector

                  Reduction of environmental impacts and costs by reducing amount of organic solvents needed
                                                                                                                                            Sensitivity results from different separation modes in HPLC vs SFC

                                                                                                                                      Supercritical fluid has unique properties different from liquid.
                                                                                                                                      Using SFC in front of a mass spectrometer offers greater sensitivity than achieved with LC/MS/MS.
                  Higher resolution
                                                                                                                                               LC/MS/MS                                          SFC-MS/MS
                                                                                                                                           6.0                                               6.0
            Improved separation and detection capabilities result from the low viscosity and high diffusion coefficient of supercritical
            fluid. As shown below, Nexera UC demonstrates high-separation selectivity for isomeric compounds that are difficult to
            separate by conventional LC.                                                                                                                                               6×
                                                                                                                                                                                    More Sensitive
                                 HPLC                   Rs = 1.328                                                                        1.0
                                                                                                                                           0.0                                               0.0
                                                                                                                                            0.0      0.5      1.0      1.5      min            0.0      0.5      1.0      1.5     min

                                                                                                                                                                   Comparison of peak intensity detected by the same MS detector.
                                                                                                                                                                             (Sample: Prostagrandin D2 10 pg)




                                                                                                                                            Enhanced sensitivity using splitless transfer to MS
                              0               4               8                12           min
                                                       Approx. 1/3                                                                    Low dead volume back pressure regulator suppresses diffusion of peaks and can transfer the total eluate directly to a mass
                                                                                                                                      spectrometer to achieve higher sensitivity.


                                 SFC                                                                                                          3.0                                             3.0
                                                                   Rs = 1.703                                                                     Split                                          Split-less
                                                                                                                                                  (Split ratio vent:MS = 8:2)                2.5
                                                                                                                                              2.0                                             2.0
                                                                                                                                                                                       5×
                                                                                                                                                                                    More Sensitive
                                                                                                                                              1.0                                             1.0
                                                                                                                                             0.5

                                                                                                                                              0.0                                             0.0
                              0            1            2           3            4          min                                                 0.0      0.5      1.0       1.5  min           0.0       0.5      1.0      1.5   min

                                   Comparison of retention time and separation acquired by Conventional LC and SFC                                               Comparison of intensity of two peaks detected by the same MS detector.
                                              (sample: α-tocopherol, column: Shim-pack UC-X Sil)                                                                                (Sample: Reserpine 10 pg)

                                                                                                                                                                                                                            Nexera UC
      8                                                                                                                                                                                                            Supercritical Fluid Extraction/Chromatograph System  9
   3   4   5   6   7   8   9   10   11   12   13