Page 12 - Shimadzu DTG-60 Series
P. 12

TGA & DTA                                                                                                                 Options






            Thermogravimetric Analyzer                         Standard Suspended-Type High-Sensitivity                                 Flow controller FC-60A
            TGA-50 Series      TGA                             Thermobalance                                                            (P/N 346-67995-92: for 120V, -93: for 230V)
            Micro and Macro Series of Thermogravimetric                                                                               The FC-60A  ow controller is used to control the  ow rate of atmosphere
            Analyzers withAdvanced Thermobalance Design                                                                               gases (of two channels). Since the gas ON/OFF control is performed
                                                                                                                                      according to a temperature program, the atmosphere can be automatically
            The TGA-50 series is equipped with a lightweight balance mechanism and
            taut band fulcrum. These have outstanding vibration resistance and                                                        changed during a measurement.
            provide for stable high sensitivity measurements. These instruments have                                                  Specifications
            an extremely wide applicability range, from measuring large-volume
            samples that cannot be measured using TG/DTA systems, or allowing the                                                      Primary pressure  0.6MPa max.
            use of a variety of sample cell sizes.                                                                                     Flow rate       PURGE side: 0~500ml/min (calibrated for N2)
            The lineup offers two types to choose from depending on the application:                                                                   DRY side: 0~500ml/min (calibrated for N2)
            the H model for high temperatures, and the 51 model, which is a macro                                                                      PURGE: 2 IN, 1 OUT
            type.                                              Specifications                                                          Flow line       DRY: 1 IN, 1 OUT
                                                                               TGA-50,    TGA-51  : Ambient to 1000°C                  Size and weight  W 180 × D 200 × H 90mm, approx. 3kg
                                                                Temperature range
                                                                               TGA-50H, TGA-51H: Ambient to 1500°C                     Power supply    90~130V AC or 210~230 V AC, 100VA
                                                                               ± 20 mg, ± 200 mg (TGA-50/50H)
                     Taut band                                  Measuring range
                                                                               ± 20 mg, ± 200 mg, ± 2 g, (TGA-51/51H)
                     Balance beam
                                              Gas inlet (2)     Weight Readability  0.1µg
                                        Magnet
                     Radiation fin            Gas inlet (1)     Sample mass    1 g including tare (TGA-50/50H)
                                                                               10 g including tare (TGA-51/51H)
                                                                Atmosphere     Air and inert gas                                        Sample Sealing Crimp Press SSCP-1
                                                                               TGA-50/50H W: 173 x D: 550 x H: 500 (mm), 23 kg          (P/N 222-13130-91)
                        Thermocouple                            Dimensions and weight
                                        Heating furnace                        TGA-51/51H W: 173 x D: 600 x H: 540 (mm), 25 kg        Samples are prepared with various types of pans for Shimadzu thermal analyzers by using the SSCP-1 in combination with the attachment specifically for the
                        Sample                                                 TGA-50  AC 100 V, 120 V, 230 V 1000 VA  50/60 Hz       pan to be used (sold separately).
                                                                Power supply
                                                                               TGA-51/50H  1200 VA, TGA-51H 1500 VA
                                                                                              Detailed brochure C160-E012A            Attachments
                                                                                                                                          Pan to Be Used      P/N          Description
                                                                     TGA
                                                                      %                                                                *1  201-52943       222-13053-91   Crimp attachment
                                                                     100.1                                                               Al crimp pans
                                                                                                                                       *2  346-66963-91    222-12821-91   Crimp attachment
                                                                     100.0                 -0.167%                                       Al crimp pans                  (for autosampler)
                                                                                                                                       *3  201-53090
                                                                                                                                         222-13175-93      222-12826-91   Hermetic attachment
                                                                     99.9                                                                Al hermetic pans
                                                                                                                                       *4  222-13175-94
                                                                     99.8                                                                Ag hermetic pans  222-12826-92   Ag hermetic attachment
                                                                                                                                       *5  346-68518-91
                                                                     99.7                                                                Al hermetic pans  222-12809-91   Hermetic attachment
                                                                                                                                                                        (for the DSC autosampler)
                                                                                                                                         (for the DSC )
                                                                                                                                       *6  346-68796-91
                                                                             50.00    100.00  150.00                                                                    Hermetic attachment
                                                                                     Temp (°C)                                           Al hermetic pans  222-12804-91   (for the DSC autosampler)
                                                                                                                                         (for the DTG)
                                                                           Measurement of the Moisture Content                         *7  222-13073-91                 Al pressure-proof pans
                                                                            of PET Fiber (using a quartz crucible)                       Al pressure-proof pans  222-12915-91   attachment
            Differential Thermal Analyzer DTA-50            DTA
            High Temperature Heat Flux DTA, provides Quantitative
            Calorimetry Measurements
                                                                                                                                        Handpress SSP-10A                                  Sealer adapter for stainless steel (SUS)
            With a unique high sensitivity dumbbell detector, which has an extremely low heat capacity, high
            sensitivity and excellent versatility, the DTA-50 offers the high sensitivity performance of the DSC                        (P/N 200-64175)                                    pressure-proof pan (P/N 222-01875-91)
            system. It is the ideal instrument for characterizing materials such as glass or ceramics.
                                                                                                                                      Used to press 5 MPa Stainless steel (SUS)          Used to seal 5 MPa Stainless steel (SUS)
            Specifications                                                                                                            pressure-proof pans ⑨.                             pressure-proof pans ⑨.
             Temperature range  Ambient to 1500°C
             Measuring range    0.2 to  1000 V /  0.2 mW~
             Atmosphere         Air and inert gas
             Dimensions and weight  W: 173 x D: 550 x H: 550 (mm), 23 kg
             Power supply       AC 100 V, 120 V, 230 V, 1200 VA, 50/60 Hz


                                                                                                                                                                                                                                  60 Series
      12                                                                                                                                                                                                                     Thermal Analysis Instruments  13
   7   8   9   10   11   12   13   14   15   16