                    Evaluation of the Temperature Characteristics of Toner                                                                    Fluidity Evaluation of Unvulcanized Rubber
                                                                                                                  Heating                                                                                               Constant
                                                                                                                                              (Rubber Compounds)


                       During laser printing, toner powder, which has a particle diameter of about 5 µm, is transferred onto copy paper and      Rubber products are produced by forming rubber compounds (mixtures of rubber and additives that provide specific functional
                       heated so that it adheres to the paper. In the case of color laser printing, this process is repeated for four different   characteristics) in a mold and then applying heat. Therefore, the fluidity of rubber compounds can have a major effect on molding
                       colors. If the melting temperature and melt viscosity differ for the four colors, then it could cause bleeding or poor    quality. Unformed rubber compounds change their characteristics after long storage periods, which can cause fluidity to
                       adhesion in areas printed first and reduce print quality. To prevent that, the temperature characteristics associated with   deteriorate or the molding process to fail, depending on how they are stored.
                       toner flow must be the same for all four colors.
                                                                                                                                              In this case, a rubber compound was stored at ambient temperature and low temperature for 14 days and   Test Conditions
                                                                                                                                              28 days immediately after kneading and then the fluidity was evaluated. The results showed that the given   Test Method  Constant temperature test
                    Flow Beginning Temperature and 1/2 Method Temperature for                                                                 sample could be stored at low temperatures without a significant change in fluidity, even after one month.  Die Diameter  0.5 mm
                                                                                                                                                                                                                           Die Length
                                                                                                                                                                                                                                         1 mm
                    Four Toner Colors by Constant Heating Rate Testing                                                                        Using the CFT-EX series allows evaluation of the rubber compounds storage temperatures and storage   Test Temperature  280°C
                                                                                                                                              periods without actually having to mold any parts.                          Test Pressure  20.1 MPa
                                                                                                                                                                                                                         Preheating Time  0 sec
                    The constant heating rate test was performed for all four color toners used in   Test Conditions
                                                                                                                                                           700                                                            Sample Size    1.6 g
                    the same color printer (cyan, magenta, yellow, and black).  Test Method  Constant heating rate test                                    600
                    The constant heating rate method was used to calculate characteristic values,   Die Diameter  0.5 mm                                   500                                          Test Results
                                                                           Die Length      1 mm
                    such as the softening temperature, flow beginning temperature, 1/2 method                                                             Viscosity (Pa·s)  400                           Storage Temperature  Storage Period  Viscosity (Pa·s)
                                                                        Beginning Temperature  50°C                                                                                                                          0           395.7
                    temperature, and offset temperature.                Ending Temperature  200°C                                                          300                  Ambient temperature          Ambient
                                                                                                                                                           200                  Low temperature             Temperature     14           568.1
                                                                          Heating Rate     5°C/min                                                                                                                          28           600.0
                    1/2 method temperature  : Midpoint between flow beginning and flow ending   Test Pressure  0.98 MPa                                    100  0  10  15  20  25   25   30                                  0           395.7
                                    temperatures                         Preheating Time   240 sec                                                                      Storage Period                        Low           14           447.5
                    Offset temperature   : Temperature at flow beginning stroke plus any arbitrary   Sample Size  1 g (formed into pellets)                                                                 Temperature     28           419.3
                                    offset stroke                                                                                                            Changes in Viscosity Due to Storage Methods
                    All four toner colors have very similar characteristic values. In particular, the   Test Results
                    values for the three non-black colors were almost identical.  Sample  Softening  Flow Beginning  1/2 Method  1/2 Method   Evaluation of the Temperature Characteristics                                 Heating
                                                                         Name  Temperature (°C) Temperature (°C) Temperature (°C)  Viscosity (Pa·s)
                    Ensuring that the respective temperature and fluidity characteristics are
                                                                         Cyan     76.8      105.1     132.5     248.2                         of General Purpose Plastics
                    approximately the same is important for maintaining the print quality of color
                                                                        Magenta   75.4      105.8     131.8     240.7
                    laser printers. Therefore, CFT-EX series flowtesters serve an important role in   Yellow  76.3  104.8  133.5  285.8
                    toner research and development, and quality control applications.  Black  73.8  108.5  145.9  402.4                          Determining the temperature where thermoplastic resins start softening and flowing, and measuring their fluidity properties are
                                                                                                                                                 extremely important for evaluating the properties of thermoplastic resins.

                                                                                                   1:Cyan. R
                                                                                                   2:Magenta. R                               The stroke-temperature graph shows that the sample starts flowing after it exceeds the flow beginning   Test Conditions
                                                                                                   3:Yellow. R
                                                                                                   4:Black. R
                                                                                                                                              temperature and decreases in viscosity as the temperature increases (graph slope increases). The viscosity   Test Method  Constant heating rate test
                                                                                                                                                                                                                          Die Diameter   1 mm
                                                                                                                                              can be calculated for each temperature after initial flow. To accurately determine the viscosity at each   Die Length  1 mm
                            Stroke                                               Viscosity                                                    temperature, the constant temperature method is recommended.              Beginning Temperature  100°C
                                                                                                                                                                                                                        Ending Temperature
                                                                                                                                                                                                                                         300°C
                                                                                                                                                                                                                          Heating Rate  5°C/min
                                                                                                                                                                                                                          Test Pressure  0.98 MPa
                                                           1:Cyan. R
                                                           2:Magenta. R                                                                                                                                                  Preheating Time  300 sec
                                                           3:Yellow. R
                                                           4:Black. R
                                                                                                                                                                                                                          Sample Size    1.2 g
                                                                                                                                                          Stroke                                Test Results
                                             Temperature                                    Temperature
                                          Stroke-Temperature Graph                   Viscosity-Temperature Graph                                                                   1:PE. R        Sample Name  Softening  Flow Beginning  1/2 Method  1/2 Method
                                                                                                                                                                                   2:PP. R                  Temperature (°C)  Temperature (°C)  Temperature (°C)  Viscosity (Pa·s)
                                                                                                                                                                                   3:PVC. R
                                                                                                                                                                                   4:PC. R        Polyethylene  142.4  153.6    203.6     16,370
                                                                                                                                                                                                  Polypropylene  175.6  187.2   215.6     5,716
                       Press-Forming Powdered Samples for Efficient Measurement                                                                                        Temperature               Polyvinyl chloride  175.3  208.2  234.4  6,138
                                                                                                                                                                  Stroke-Temperature Graph        Polycarbonate  183.1  205.1   253.9     10,590
                       Due to the small size of toner particles, samples could easily scatter if placed directly in the
                       sample chamber or spill out from die orifices. Therefore, for samples such as these, a hand
                       press and preforming die unit can be used to press them into a form that can be more easily                              Cylinder Cooling Fan Improves Cycle Time for Constant Heating Rate Tests
                       placed in the sample chamber. Accurate values can be measured efficiently by placing only
                       one pellet in the chamber.                                                                                               Constant heating rate test measurements start at a low and finish at a high temperature. The cylinder
                       For thermosetting resin samples, measurements can fail due to ongoing curing during the                                  cooling fan can be quickly attached to the bottom of the furnace to force-cool the cylinder, which can
                       time it takes to place samples in the sample chamber. Therefore, it is extremely important to                            significantly shorten the cooling time.
                       pelletize samples before measurement.                                                                                    A piston for force-cooling the cylinder with compressed air is also available.