Page 15 - Shimadzu CFT-EX Series
P. 15
Options
Optional Additional Dies (Nozzles)
Die Orifice I.D. × Length (mm) Shape and Material P/N
Viscosity 10 6
0.3 × 1.0 341-69057-02
(Pa·s)
0.5 × 0.5 341-69057-03
0.5 × 1.0 341-69057-04 10 5
Flat
0.5 × 2.0 341-69057-06
(high speed tool steel:
0.5 × 2.5 SKH material) 341-69057-07
1.0 × 1.0 (Included as standard) 341-69057-12 10 4
1.0 × 2.0 341-69057-13
0.3 × 1.0 341-69057-22 10 3
0.5 × 0.5 341-69057-23
0.5 × 1.0 341-69057-24
10 2
0.5 × 1.5 341-69057-25
0.5 × 2.0 341-69057-26
0.5 × 2.5 341-69057-27
10 1
0.5 × 5.0 341-69057-28
0.5 × 10.0 341-69057-29
1.0 × 5.0 Flat (stainless steel) 341-69057-34 10 0
1.0 × 10.0 341-69057-35
2.0 × 2.0 341-69057-15
10 -1
2.0 × 5.0 341-69057-17
ø1 × 1
2.0 × 10.0 341-69057-18
ø1 × 10
3.0 × 3.0 341-69057-43
ø0.5 × 1
3.0 × 6.0 341-69057-45
2.095 × 8.0 341-69057-51 Test Pressure
No orifice 341-69057-52 0.098 0.98 1.96 9.8 49 (MPa)
0.5 × 10.0 Split type nozzle 341-68997-07
1.0 × 10.0 (ultra-hard alloy) 341-68997 Reading the Graph
0.5 × 10.0 Split type nozzle 341-68997-02 Given a die with a 1 mm diameter and 1 mm long orifice, for example, and a test pressure of 1.96 MPa
1.0 × 10.0 (stainless steel) 341-68997-01
selected, then viscosities from 50 to 50,000 Pa·s can be measured.
Split type nozzle 341-69024 If the orifice length is 5 mm, then viscosity values would be 1/5 those above.
disassembly tool
Test Temperature and Pressure Range Extension Options
Low Temperature Test Attachment High Temperature Heating Attachment Large Sample Heating Attachment
(P/N 344-04024-11, 50 Hz; 344-04024-12, with a Piston (1 cm2) (P/N 347-25001-11)
60 Hz (with a transformer)) (P/N 344-81960-01) This heating attachment cylinder has a large
Used for testing at low temperatures. Used for testing at high temperatures. cross-sectional area to decrease the test pressure to 1/4
Temperature range: 0 to +90°C Temperature range: of the regular level.
CHW-1 heating attachment included 20°C above room temperature to 500°C Model: CH-4P
Cylinder cross sectional area: 4 cm 2
Piston 4 cm (P/N 347-25000-11) is required.
2
Cylinder Cooling Options (Cool the cylinder with forced air to improve efficiency of constant heating rate tests)
Cylinder Cooling Fan (P/N 347-26025) Cylinder Cooling Piston (P/N 341-69997-02)
Cylinders must be cooled rapidly after constant heating Cylinders must be cooled rapidly after constant heating rate tests to
rate tests to prepare for the next test. The cooling fan prepare for the next test. This piston blows air on the cylinder to enable
attaches to the bottom of the heating attachment to rapid cooling.
directly cool the heating attachment. Breakdown: Cylinder cooling piston and air hose
Note: Cannot be used with low-temperature test attachments. Note: Cannot be used with large sample heating attachments.
Sampling Options
Preforming Die Unit and Hand Press (P/N 347-25008-01)
Powdered samples can be difficult to insert in the cylinder. Molding
the samples in advance can make insertion easier.
Breakdown: · Preforming die unit (P/N 347-25009-01)
Solid sample dimensions: Approx. I.D.11 × L13 mm
· Hand press (P/N 347-25011)
Press force: Max. approx. 1200 N
Electronic Balance
Used to measure sample mass
CFT-EX Series
Capillary Rheometer Flowtester 15