Page 86 - Shimadu Consumables Catalog
P. 86

Microscale Columns



           Shim-pack Trap Columns


              Trap Columns Wide Portfolio

              Shim -pack MCT C18/C8
              70 MPa pressure imitation and a unique modification on the column inner surface
              protects against absorption of the molecule.
              Shim -pack MCT LC18/LC8
              A small-volume cartridge column with 40 MPa pressure limit. Useful in reducing
                 the gradient delay for a low flow rate.





              Order information
             Shim-pack MCT series                               Shim-pack MCT L series (particle size 5 μm)

             Part Number  Bonded Phase  Diameter (mm)  Length (mm)  Part Number  Bonded Phase  Diameter (mm)  Length (mm)
             228-59938-91              0.3                      227-32701-01  Trap column holder for Shim-pack MCT L
                           C18                     35
             228-59938-92              0.5                      227-32702-01  C18         0.3
                                                                                                       5
             228-59939-91              0.3                      227-32703-01   C8         0.5
                            C8                     35
             228-59939-92              0.5
              Nexer Mikros: Trap and Elute Confirguration

           The trap and elute system can be constructed by using a dedicated piping kit (228-71751-42).


                                                                            Nexlock ™  ID 0.05 mm × 100 mm



                                              SIL-40C XR       Trap column
                         A pump
                                                                                      Waste
                                        Mixer
                                                                 2   1
                                                                3     6
                                                                 4   5  FCV-0206H
                         B pump

                        LC-40B X3
                                                                                           MS
                                                                            Analysis column
                                              A pump
                                                                       Nexlock ID 0.05 mm × 600 mm


                                                             Nexlock ID 0.05 mm × 100 mm
                                              B pump

                                                LC-Mikros












         Pg A-82
   81   82   83   84   85   86   87   88   89   90   91