            ■ Sampling                                          ■ Remote control
            An analysis system is only as good as the           The  measuring  instruments  can  be  started
            sample  preparation preceding  it. Various          and calibrated from a control station, and a
            sample preparation systems are available for        selection between the different  measuring
            the 4200 series, which can be optimally tuned       streams  is  possible.  Numerous  alarm  and
            to the individual application area. When            status signals simplify detection of exceeded
            sewage plant inlet and outlet are to be             limit levels and indicate the need for
            measured  using  the  same  instrument,  the        maintenance. In addition to the conventional
            sample     stream     switcher    is    used.       communication      modes,      a     Modbus
                                                                communication  channel  is  available.  An
                                                                optional web browser enables a ‘view’ of the
                                                                instrument from any  networked computer.
                                                                The  software  counts  consumables  such  as
                                                                acids and pure water for dilution, and emits a
                                                                signal to the measuring station for refilling the
                                                                consumables.

                                                                ■ Recommended analyzer / Configuration
                                                                TOC-4200
                                                                Multi-Stream suspended solids sampling unit
                                                                Acid Rinse option










                        Fig. Multi-Stream switcher

            The sample enters the sample chamber via a
            strainer,  where  it  is  homogenized  through  a
            rotating knife before it  is transferred to the
            instrument for analysis. This way, even
            samples    containing   large   amounts    of
            particulate  matter can be measured without
            any problems. After sampling, the chamber
            and the strainer are cleaned with rinsing
            water. Depending on the application, the
            rinsing water can be  acidified in order to
            prevent the growth of algae. The rinsing
            function prevents any carry-over effects when
            changing sample streams. The  measuring             [1] Source: Wikipedia
            program can be individually selected for each
            sample  stream. In addition, the  user can
            freely choose the measuring sequence of the
            sample streams.