Page 7 - Shimadzu-FoodSafety
P. 7

Analysis of Residual Pesticides  Analysis of Veterinary Pharmaceuticals






 Gas Chromatograph (GC)  Liquid Chromatograph (LC)  Veterinary pharmaceuticals are used in the diagnosis, cure, mitigation, treatment, and prevention of diseases in animals as
                    well as in the promotion of growth. However, there is increasing concern about these drugs entering the food chain and their
 Capillary GC can be utilized for the analysis of residual   GC or GC-MS techniques may not be suitable for analysis of
 pesticides in foods. Using a selective detector such as FPD,   residual pesticides that thermally decompose or have a   effects on the human body. These drugs are categorized in many classes, such as anabolic hormones, anthelmintics,
 FTD or ECD offers highly sensitive analysis of trace pesticides.  highly polar chemical structure. In contrast, an HPLC   antibiotics, beta-agonists, coccidiostats, corticosteroids, nonsteroidal anti-inflammatory drugs (NSAIDs), and sedatives. Below
 equipped with a photodiode array detector can acquire   are a few examples of veterinary pharmaceutical analyses.
 reliable chromatograms with spectral information for
 methamidophos  chlorpyrifos-methyl + dimethoate  (E)-dimethylvinphos  fenthion  (Z)-dimethylvinphos  (Z)-chlorfenvinphos  fosthiazate 2 + prothiofos  building libraries to compare compounds. The Shimadzu   Analysis of Multiple Veterinary Pharmaceuticals in Pork (LC-MS/MS)
 carbamate analysis system incorporates derivatization

 dichlorvos  acephate  thiometon  salithion  terbufos  diazinon etrimfos iprobenfos  dichlofenthion  cyanophos tolclofos-methyl pirimiphos-methyl  formothion  malathion  fenitrothion (MEP)  isophenphos + quinalphos  phenthoate  profenofos + methidathion  ethion + sulprofos  pyridaphenthion  technologies to achieve high-sensitivity, selective analysis of   Veterinary pharmaceuticals are often used to promote the growth of farm animals, but many of these compounds are subject
 N-methyl carbamate pesticides.
                    to residue standards. From this background, there is a need for a highly sensitive and rapid analytical technique to analyze as
 cadusafos ethoprophos  phorate  chlorpyrifos  (E)-chlorfenvinphos  fosthiazate  propaphos  butamifos  edifenphos  fensulfothion  cyanofenphos  EPN  phosmet  phosalone  pyraclofos  60 mV  many of these compounds as possible in a single run. LC-MS/MS enables simultaneous analysis of multiple veterinary
                    pharmaceuticals with high sensitivity.
 50  Oxamyl  Methomyl  Methiocarb sulfoxide  Aldicarb
 Pesticide-spiked meat dumpling sample (0.2 µ g/g equivalent)  Methiocarb sulfone  Carbaryl  Triple Quadrupole Mass Spectrometer
 40  Ethiofencarb
 Normal meat dumpling sample  Bendiocarb  Fenobucarb                                     LCMS-8060
 30  Methiocarb
 Chromatograms of Normal Meat Sample and Pesticides-spiked Meat Sample
 20
 Gas Chromatograph Nexis GC-2030  10
 0
 0.0  5.0  10.0  15.0  20.0  25.0 min
 Chromatogram of a Standard Mixture of 10 N-Methylcarbamate Pesticides
                                  MRM Chromatograms of 89 Veterinary Pharmaceuticals in Pork
 High-Performance Liquid Chromatograph                     Source: Shimadzu Application News No. C99
 Prominence Series
 Carbamates Pesticides Analysis System
                    Analysis of Veterinary Pharmaceuticals Using MRM Spectrum Mode (LC-MS/MS)
                    MRM Spectrum Mode was developed to reduce false positives and false negatives in analysis of veterinary pharmaceuticals.
                    MRM Spectrum Mode acquires a high number of fragment ion transitions for each target compound and generates
                    fragmentation spectra. In examination of quantifying and identifying 212 veterinary pharmaceuticals, the level of confidence
                    in compound identification and verification increased in MRM Spectrum Mode, and limits of detection, linearity or
 Features
                    repeatability were not compromised compared to a conventional method (2 MRM / compound).
 Easy Operation
 An advanced interface enables intuitive operation with clear
 graphics. Shimadzu's latest tool-free maintenance technology makes
 daily maintenance easy.
 High Sensitivity and Reproducibility  Features
 Achieves high sensitivity with all of the detectors, such as FID and   Rapid Injection
 BID. The advanced flow controller (AFC) enhances reliability with   An injection time of 10 seconds for a 10 µL sample enhances analysis
 excellent repeatability.  efficiency.
 Exceptional Expandability and Productivity  High Sensitivity and Linearity over a Broad Range
 Nexis GC-2030 can be customized to meet customers' specific   Upgraded optical and electrical systems reduce noise for lower
 requirements and needs. Options and functions to use hydrogen   detection limits and ensure simultaneous analysis of major
 carrier gas safely in high-speed analysis maximize analysis   components and trace components.
 productivity.  Low Sample Carryover
 Platinum coating minimizes the adsorption of sample components
 on to the needle surface.                      MRM Spectra and Calibration Curve of Sulfamerazine (1 pg/µL to 100 pg/µL)
                                                                                              Source: Shimadzu Application News No. C161




                                                                 Shimadzu’s Total Support for Food Safety
 6                                                                                                Analytical and Testing Instruments for Food Safety  7
   2   3   4   5   6   7   8   9   10   11   12