Page 11 - Shimadzu-FoodSafety
P. 11

Analysis of Toxic Metals  Analysis of Food Additives






 Toxic metals (arsenic, lead, cadmium, etc.) in foods must be controlled down to low concentration levels.  A wide variety of additives, such as preservatives, flavor enhancers, coloring agents and antioxidants, are used on foods.
 Shimadzu atomic absorption spectrophotometers and ICP emission spectrometers offer highly sensitive analysis of trace   Strict monitoring of food stuffs is essential to detect the use of prohibited chemicals. Each country assigns a unique number or
 elements in foods. Shimadzu’s product lineup also includes X-ray fluorescence spectrometers that can perform elemental   code of approved chemicals for that country. Shimadzu offers a wide range of products for detecting the prohibited
 analysis without sample pretreatment. These instruments are ideal for screening analysis and emergency analysis.  chemicals, whether they were added intentionally or through contamination.

 Analysis of Cd and Pb in Food Additives (AA)  Atomic Absorption Spectrophotometer AA-7000  Analysis of Dicyandiamide and Melamine in Milk Powders (LC-MS/MS)
 Shown here is an analysis of cadmium (Cd) and lead (Pb) in   Melamine was found to be used as a protein-rich adulterant   residues were found in milk products from New Zealand.
 α-cyclodextrin (cyclic oligosaccharide), a substance used in   in pet food in 2007, and then in infant formula in 2008 in   Instead of being added directly as an adulterant, the trace
 functional foods, pharmaceuticals, cosmetics, etc. The   China. The outbreak of the melamine scandal that killed   DCD, which is used for promote the growth of cow pastures,
 analysis was conducted by the AA-7000 atomic absorption   many dogs and cats as well as led to the deaths of six infants   found in milk products was explained to be relating to the

 Abs  Abs           and illness of many others caused panic and great concerns   grass “contaminated by DCD”.
 Cd  Pb             worldwide. Recently, low levels of dicyandiamide (DCD)   (x100)              (x1,000)
 STD 1 µg/L                                                                6.0                 4.5
                      Area (x10,000)          Area (x100,000)                 DCD              4.0  Melamine
 STD 10 µg/L                                 3.5                           5.0  (85.1>68.1)    3.5  (127.1>85.1)
                    7.5  DCD (85.1>68.1)        Melamine (127.1>85.1)
                       R2 = 0.997            3.0  R2 = 0.999               4.0                 3.0
 Sample
 Sample  Sample                              2.5                                               2.5
 Sample
 w/Spike
 w/Spike
 w/Spike
 w/Spike            5.0                      2.0                           3.0                 2.0
 Measurement Results of Cd and Pb in α-cyclodextrin
                                             1.5                           2.0                 1.5
 Sample
 Sample  Element  Cd  Pb  2.5                1.0                                               1.0
 Sample  w/o Spike                                                         1.0
 Sample
 w/o Spike
 w/o Spike
 w/o Spike  Measured value  <0.003 µg/g  <0.07 µg/g  0.5                                       0.5
                                                                           0.0                 0.0
 Spike and recovery rate  105 %  99 %  0.0   0.0
 0  3sec  0  3sec    0.0  2.5  5.0  7.5  Conc.  0.0  2.5  5.0  7.5  Conc.   2.00  2.25  2.50  2.75  min  5.5  6.0  6.5  min
 Peak Profiles of Cd and Pb     Calibration Curves of DCD and Melamine     Overlapping of Six MRM Peaks of 0.5 ng/mL DCD and Melamine in Milk
                                                                           Powder Matrix
 Analysis of Trace Element Contamination in a Fish   ICP Atomic Emission Spectrometer ICPE-9800 Series  Analysis of Preservatives in Food (UV)  Analysis of Sudan Dyes in Curry Powder (LC)
 Sample (ICP)
                    Below are examples of the analysis of food samples spiked with   Sudan dyes are oil-soluble synthetic dyes used in industrial
 Fish Protein Certified Reference Material for Trace Metals   preservatives.  products. Their use is not authorized in food products in some
 (DORM-4) was used as the fish sample. The Shimadzu
 ICPE-9800 can provide a rapid method to simultaneously   0.7          countries. This is an example of LC analysis of Sudan dyes in
                                                     8µg               curry powder.
 analyze trace elements in fish. The results show excellent
                                             0.6
 correlation with the certified reference material.   6µg
                      0.7      0.5µg         0.5                       mAU       3  4                           Peaks
                      0.6                                                                                       1 Sudan Orange G-a
 Cd 214.438nm  Standards  Cr 205.552nm  Standards  0.5  0.4µg  Abs.  0.4  4µg                                   2 Sudan Orange G-b
                                                                                                                3 Sudan Red G
                     Abs.  0.4  0.3µg  Sample  0.3                      20             5  6                     4 Sudan I
 Samples  Samples     0.3      0.2µg         0.2     2µg                15                                      5 Sudan II
                                                                                                                6 Sudan III
                      0.2                                                       2                     8         7 Sudan Red 7B
 Peak Profiles of Cd and Cr  0.1  0.1µg      0.1                                                   7            8 Sudan IV
                                                                        10                              Curry powder
                         450  500  550  600  650    250  nm  300  350         1                         +Sudan dyes
                               nm
                                                                        5
 Usage and Features of Elemental Analysis System  Sodium Nitrite in Meat  Sorbic Acid in a Processed
                                               White Fish Product                                       Curry powder
 Product  Usage / Feature  Sample                                       0
                                                                         0.0  2.5   5.0  7.5  10.0  12.5  15.0  min
 Atomic absorption spectrophotometry is widely used for tests compliant with various standards   UV-VIS Spectrophotometer UV-1900
 Atomic Absorption                                                                  Sudan Dyes in Curry Powder
 Spectrophotometer  due to its high sensitivity. AA-7000 offers superior expandability due to its flexible system   Liquid (or sample
 configuration. It also offers numerous safety features, such as a vibration sensor and a gas
 dissolved in solvent)
 AA-7000 Series     Features                                                        Source: Shimadzu Analysis Guidebook No. C180-E059, page 77
 leakage detection system, as standard.
                    High Performance
 ICP atomic emission spectrometry is widely used for tests compliant with various standards due to
 ICP Atomic Emission  Liquid (or sample  ・Ultra-fast scan speed (29,000nm/min)
 Spectrometer  its high sensitivity and rapidity when performing multi-element simultaneous analyses. ICPE-9800   dissolved in solvent)
 series offers numerous features, including the simultaneous analysis of all elements, simple
 ICPE-9800 Series   ・Low stray light (less than 0.5% at 198nm)
 operation with its assistant functions, and low running costs.
                    ・High photometric repeatability (less than
 ICP mass spectrometry is a method of analysis that provides ultra-high sensitivity at ppt levels in   ±0.0002Abs at 0.5Abs and 1.0Abs)
 ICP Mass Spectrometer  addition to simultaneous multi-element analysis capabilities. ICPMS-2030, while being highly   Liquid (or sample  Intuitive Operability
 ICPMS-2030  sensitive, also offers low running costs by reducing the argon gas flow. It also greatly improves   dissolved in solvent)
 the reliability of data through its assistant functions.  Easy-to-navigate color touch-screen display
                    Instrument Validation
 X-ray fluorescence spectrometry makes possible the nondestructive analysis, without
 X-Ray Fluorescence  pretreatment, of the elements in solid, powder, or liquid samples. EDX-7000/8000 are capable of   Automatic/semi-automatic validation of
 Spectrometer  Solid, powder, liquid
 EDX-7000/8000  detecting sub-ppm level heavy elements. Offering low running costs and superior maintenance   wavelength accuracy and wavelength
 features, these instruments are suitable for the screening of toxic metals.  reproducibility.
                                                                 Shimadzu’s Total Support for Food Safety
 10                                                                                               Analytical and Testing Instruments for Food Safety  11
   6   7   8   9   10   11   12   13   14   15   16