Page 4 - Shimadzu SMV-301/301RT
P. 4

Simple Cleaning and High Safety Improve Testing Ef ciency                                                                 A Color LCD Touch Panel Improves Testing Ef ciency by

                                                                                                                                              Improving Testing Operations




                                                                                                                                              A color LCD touch panel makes it easy to specify test conditions. It also includes extensive data analysis functionality, such as for
                                                                                                                                              displaying results, performing statistical calculations, editing data, and displaying graphs.


                                                                                                                                                   Creating and Loading Test Conditions

                                                                                                                                              All test conditions can be set via the screen.
                                                                                                                                              Saved test conditions can be loaded from a  le. Up to 10 values can be
                                                                                                                                              speci ed for Mooney viscosity detection time, rotation speed (on RT
                                                                                                                                              models), or scorch point settings. Mooney viscosity values can be used for
                                                                                                                                              automatic pass/fail decisions as well.                  Screen for setting conditions


                                                                                                                                                                                                                          Screen for loading condition settings


                                                                                                                                                        Start Test ⇒ Preheat ⇒ Test

                                                                                                                                              The auto-start function automatically lowers the crosshead and starts preheat-
                                                                                                                                              ing as soon as the windbreaker casing is closed. After preheating, it automati-
                    A windbreaker casing is also included standard.                                                                           cally starts the test. If multiple measurement conditions are set, in addition to
                                                                                                                                              displaying results when the test is  nished, interim results for each setting can
                    The auto-start function is linked to the casing to improve both safety and ef ciency.                                     be displayed at any time during measurements.           Time vs. Mooney value graph
                    The casing prevents external disturbances from the surrounding temperatures during measurements and prevents temperature variations around the
                    die. An interlock mechanism prevents the crosshead from ascending or descending except when the casing door is closed. The viscometer also includes                                                   Enlarged display of real-time values
                                                                                                                                                                                                                          during measurements
                    an auto-start function that can automatically start tests when the casing door is closed while in the standby mode. These functions help ensure that
                    tests can be performed ef ciently and safely.                                                                                Display Results, Print Reports, or Output Data
                    Installing an optional display tower signals a warning to surrounding personnel.
                                                                                                                                              After testing is  nished, Mooney viscosity criteria speci ed in advance or pass/fail
                                                                                                                                              results based on those criteria can be displayed, and a logarithmic graph of
                    The rotor lifting function makes cleaning easier.                                                                         scorch time or stress relaxation measurements can be plotted automatically. Test

                                                                                                                                              results can be printed out directly from the touch panel (printer is optional), or
                    Mooney viscosity testing requires cleaning the die and rotor after each                                                                                                           Test results
                                                                                                                                              test conditions, results, and raw data can be output to a PC.
                    test. Because the surface of SMV-301/301RT rotors is treated to prevent
                                                                                                                                                                                                              Stress relaxation
                    sticking to samples, while also maintaining adequate rotor hardness,
                                                                                                                                                                                                              measurement results  Example of stress relaxation
                    samples are much easier to peel off of the rotor after tests. The rotor                                                                                                                                    measurement report output
                    lifting function also makes it easier to remove the rotor after tests.
                                                                                                                                                            Statistical Processing

                                                                                                                                              All data with the same sample number in test conditions can be processed
                    A warm-up function provides a smoother test starting process.                                                             as one  le for statistical processing. Saved test results can be displayed,
                                                                                                                                              statistical data plotted, or histograms created.
                                                                                                                                                                                                                                  Example of
                    This function automatically warms up the system to a speci ed tempera-                                                                                                                                     printing data  le
                    ture, so that it is ready to start testing at the speci ed time.
                    It also allows saving and loading test conditions, thereby improving the
                    ef ciency of testing using multiple different conditions.


                                                                                                                                                                                                                 Example of printing statistical calculation results
                                                                                                                                                 Plot                   Histogram
                                                                                                                                                                                                                            SMV-301/301RT
             4                                                                                                                                                                                                                    Mooney Viscometer    5
   1   2   3   4   5   6   7   8   9