Page 2 - Shimadzu SMV-301/301RT
P. 2

Measuring the Mooney Viscosity and                                                                                        Full Compliance to Global Standards


                    Scorch Time of Raw or Unvulcanized Rubber                                                                                 The SMV-301 / 301RT allows the user to measure the Mooney viscosity, scorch time, minimum Mooney viscosity, and other characteristics of rubber

                                                                                                                                              in accordance with JIS, ISO, and ASTM test methods. With outstanding temperature recovery characteristics and easy operability, it can also be used
                                                                                                                                              for stress relaxation measurements or for tests that involve varying the rotor speed.
                    Mooney Viscometer
                    SMV-301/301RT                                                                                                                  JIS K 6300-1: Rubber, unvulcanized – Physical property –
                                                                                                                                                                        Part 1: Determination of Mooney viscosity and pre-vulcanization characteristics with Mooney viscometer
                                                                                                                                                   ISO 289-1,2,3,4: Rubber, unvulcanized – Determinations using a shearing-disc viscometer
                                                                                                                                                   ASTM D 1646: Standard Test Methods for Rubber
                                                                                                                                                                          – Viscosity, Stress Relaxation, and Pre-Vulcanization Characteristics (Mooney Viscometer)
                    SMV-301/SMV-301RT Mooney viscometers feature a color LCD touch panel display that allows the instrument to be
                    operated by anyone and enhances safety.
                    In addition to plotting Mooney viscosity curves, the SMV-301/301RT systems include extensive functionality for
                    statistical analysis.                                                                                                     Max. 200 M Capacity (or optional 400 M capacity)
                                                                                                                                              The automatic calibration unit (optional) allows weights to be automatically
                                                                                                                                              calibrated to ensure high testing reliability.


                                                                                                                                              A V-groove die compliant with JIS, ISO, and ASTM standards ensures tests can
                                                                                                                                              be performed in accordance with global standards.                                       V-Groove Die
                                                                                                                                              Torque can be calibrated easily via the touch panel by calibrating weights
                                                                                                                                              using the automatic weight calibration unit (optional). The ability to perform
                                                                                                                                              routine sensitivity calibration electronically via the touch panel ensures highly
                                                                                                                                              reliable routine testing.



                                                                                                                                              Excellent thermal stability and temperature recovery
                                                                                                                                              characteristics enable high reproducibility.                            Temperature    SMV-301/300


                                                                                                                                              Optimal control and  lm heater units provide shorter temperature recovery   Set
                                                                                                                                                                                                               temperature             SMV-202/201
                                                                                                                                              times after inserting specimens and, due to the highly stable temperature
                                                                                                                                              control system, highly reproducible test results.                                 Temperature   Time
                                                                                                                                                                                                                        Sample inserted  Test started
                                                                                                                                                                                                                                Recovery Curve

                                                                                                                                              Also supports stress relaxation testing, cycle testing,

                                                                                                                                              and variable rotor speed testing.

                                                                                                                                              The SMV-301RT can also measure stress relaxation and decay in accordance with ISO 289-4 and ASTM D 1646. In addition, the difference in viscosity
                                                                                                                                              between samples can be determined more easily by using multiple rotor speeds (between 0.1 and 20 rpm) during testing to evaluate mixing or by varying
                                                                                                                                              the strain level. Performing various tests in that manner allows viscoelasticity of rubber samples to be evaluated.









                                                                                                                                                   Mooney Viscosity Test  Mooney Scorch Test  Stress Relaxation Test   Cyclic Test  Variable Rotor Speed Test
                                                                                                                                                                                          (SMV-301RT)        (SMV-301RT)        (SMV-301RT)
   1   2   3   4   5   6   7