Page 8 - Shimadzu LCMS-8045
P. 8

LabSolutions LCMS                                                                                                           Automatic Calculation of Dwell Time

                                                                                                                                      The optimum dwell time is calculated automatically from the number of
                                                                                                                                      overlapping MRM channels and maximum loop time, thereby obtaining
            Shimadzu's data acquisition software provides a single point of control for LC and MS parameters. In addition, by incorporating   the necessary data points for the entire analysis.
            critical input from customers, Shimadzu provides laboratories with software tools to address specific laboratory workflows and
            improve productivity.



              Fully Automated MRM Optimization
            It's faster and easier to optimize quantitative parameters with updated software that reduces MRM optimization time by 25%.


                 Previous version: Before starting voltage optimization, precursor m/z must be input.
                                     Input
                                           Voltage                                                 Voltage
                   Searching Precursor Ion                CE Optimization      Searching Product Ion
                                        Optimization 1                                           Optimization 2
                                                                                                                                      Optional Software Programs
                 New version: Precursor m/z is automatically picked from full scan spectra based on a preset rule.
                                                                                                                                      Shimadzu offers numerous options to address specific customer requirements.
                  Searching Precursor Ion
                                     Searching Product Ion                                 25% Time Savings                           Combining LabSolutions LCMS with these programs improves workflow efficiency.
                                                         CE Optimization
                                                                          Voltage Optimization
                                                                                                                                        LC/MS/MS Method Packages and MRM Libraries

                                                                                                                                      A variety of method packages and MRM libraries, which include analysis conditions such as MRM parameters, enable efficient implementation of
              Intuitive User Interface                                                                                                simultaneous multi-component analyses. The method parameter list included in these packages can be used to create methods that analyze targeted
                                                                                                                                      components only. These packages can save laboratories a great deal of method development time.
            A new approach helps simplify the user experience for high-throughput laboratories. Quick batch makes it easier to perform routine LC/MS/MS analyses
            and changes to the Control Panel help method development.                                                                                                                                    Description    Flyer code
                                                                                                                                                                                                       Residual Pesticides  C146-E306
                                                                                                                                                                                                        Veterinary Drugs  C146-E161
                                                                              Method development
                                                                                                                                                                                                      Water Quality Analysis  C146-E180
                                                                              An updated Control Panel makes it easier to                                                                               Drugs of Abuse
                                                                              change LC/MS/MS methods.                                                                                                                  C146-E181
                                                                                                                                                                                       Method Packages  Rapid Toxicology Screening  C146-E224
                                                                                                                                                                                                       Primary Metabolites  C146-E227
                                                                                                                                                                                                        Lipid Mediators  C146-E225
                                                                                                                                                                                                       Cell Culture Profiling  C146-E279
                                                              Control panel                                                                                                                             D/L Amino Acids  C146-E336
                                                                                                                                                                                                     Metabolic Enzymes in Yeast  C146-E275
                                                                                                                                                                                        MRM Libraries
                                                                                                                                                                                                      Phospholipid Profiling  C146-E314
                                                                                                                                                                                      Note: Optimization of analysis parameters will be necessary in some cases
                                                                                                                                                                                         when using the LCMS-8045.

                                                                                                                                        Traverse MS

                                                                                                                                      Multivariate Analysis Software Supports MRM Data
                                                                                                                                      Traverse MS data analysis software is intended for high-speed processing of
                                                                                                                                      MRM data acquired with Shimadzu triple quadrupole LCMS systems in the field
                                                                                                                                      of targeted metabolomics.
                                                                                                                                      Using multiple samples and multiple components, the software is able to
                                                                                                                                      create graphical and statistical analysis for metabolic pathway analysis.
                              Quick Batch
                              Streamlines sample submission. A simple
                              color-coded autosampler graphic offers quick
                              visualization of the sample queue. Three color
                              codes have been designed for standards (sky
                              blue), unknowns (purple) and controls (yellow).


                                                                                                                                                                                                                           Brochure: C146-E308
                                                                                                                                                                                                                           LCMS-8045
      8                                                                                                                                                                                                                Liquid Chromatograph Mass Spectrometer  9
   3   4   5   6   7   8   9   10   11   12