Page 10 - Shimadzu LCMS-8045
P. 10
Multi-analyte Quantitation Software
LabSolutions Insight Nexera UHPLC Series
Laboratory efficiency is driven by highly automated mass spectrometry platforms delivering large volumes of high-quality data. Shimadzu's unique approach to delivering high-quality,
However, manual data review can limit sample turnaround times and reduce productivity. LabSolutions Insight has been designed high-speed LC/MS/MS analysis combines the Nexera UHPLC
to drastically simplify the review process and transform data processing. and LCMS-8045 as a seamlessly integrated system.
Multi-Analyte Data Review
Results can be re-integrated and re-quantified directly from LabSolutions Insight.
Color-coded QA/QC Flags
In LabSolutions Insight, quantitative results can be compared to established criteria, and any outliers are color-coded for easy identification and further Key elements of Nexera and LCMS-8045 performance to maximize your productivity
review. Color-coded criteria levels can be defined, making it easy to determine which data points are outliers, and which specific QC criteria were not
met. Any changes made to calibration curves or manual peak integration are immediately reflected in the color-coded flags. Nexera LCMS-8045
The fastest gradient cycle and sample injection time Pause time 1 msec, Dwell time 0.8 msec
Color-coded flags Eliminates carryover even with high-sensitivity LC/MS/MS 5 msec polarity switching speed
Solvent blending and sample preparation are possible No signal loss even at lower dwell time with UFsweeper technology
Cautionary Warning
0.000001 mg/L 0.00001 mg/L
Nexera X2 Nexera XR Nexera MP Nexera-i
Sample Survey
Brochure: C196-E079 Brochure: C196-E082 Brochure: C193-E030 Brochure: C196-E084
Compound Information
Nexera UC
Multiple Workspaces Laboratory On-line SFE-SFC-MS System
Insight supports data review over a network, creating new opportunities in GC/MS/MS analysis LC/MS/MS analysis This revolutionary system combines on-line SFE and SFC in a single flow path. Target compounds are extracted from solid samples and then
remote data review, and enables multiple panel display for two monitors. automatically transferred to SFC/MS so that no human intervention is required. The Nexera UC on-line SFE-SFC system reduces the time for
pretreatment of samples and acquires highly accurate data.
Analyst Analyst
Office
Data confirmation Data review
Analysis
administrator Analyst
Client PC Client PC
Brochure: C190-E185
LCMS-8045
10 Liquid Chromatograph Mass Spectrometer 11