Page 7 - Shimadzu Xslicer SMX-6010
P. 7

Simple Operation








 Switch Smoothly between Fluoroscopy and CT  Wide CT Imaging Range

 Switch between fluoroscopy and CT imaging by simply clicking on the menu tab.  CT images can be obtained at any position within a 350 mm x 350 mm area. There is no need to move the sample to the center of
 The Xslicer SMX-6010 features tilted CT imaging. X-ray fluoroscopic images are captured and cross-sectional images are created by   the rotary table as in conventional tilted CT, allowing the scan to be positioned just by clicking on the scanning site.
 tilting the flat panel detector and rotating it 360 degrees. There is no need to install a separate unit for CT imaging.
 The CT imaging scan conditions are easy to configure just by selecting the scan mode, scan angle, and scan region.
 A region of interest in the fluoroscopic image can be observed immediately with a CT scan.












 Fluoroscopic Image  Simply select the imaging   CT Imaging
 conditions ([Simple],
 [Normal], or [Sharp]) and
 the imaging angle.







 High-Speed Imaging and High-Speed Reconstruction

 The calibration procedures are completely automated to speed up the imaging process.
 Cross-sectional images can be displayed in as little as two minutes after CT imaging starts.  Set Tracking Points Easily

               If a tracking point is set, the observation position of interest when tilted and rotated never leaves the center of the window.
               As a result, the point of interest is never lost.
               To set a tracking point, simply tilt the detector and double click the position of interest.









                                                                                         Tracking point
 7.5 to 20 times higher throughput                                                       settings value
                                                                         Tracking ON
                                                                When tilted, the point of interest never
                                                        leaves the center of the window because the stage tracks it.



                       Not tilted
                  (The point of interest is
                    marked with a 〇.)


 15 to 40 minutes
                                                                         Tracking OFF
                                                         When tilted, the point of interest does not remain at the
                                                         center of the window because the stage does not track it.



                                                                                         Xslicer SMX-6010
 6                                                                                              Microfocus X-Ray Inspection System  7
   2   3   4   5   6   7   8   9   10   11   12