Page 12 - Shimadzu Xslicer SMX-6010
P. 12

System Configuration                                                                                                Principles and Features of Planer CT Imaging








                       An easy-to-maintain                                                                                                 Capable of Maximum Image Enlargement for Planer Samples

                       Shimadzu X-ray generator and various safety mechanisms
                       reduce costs and ensure safe use.                                                                                   Planer CT
                                                                                                                                                                                                  Scanning large circuit boards
                                                                                                                                                X-ray detector                                    with planer CT:
                                                                                                                                                                                                  The sample is mounted on an XY stage, so it
                                                                                                                                                                                                  can approach the X-ray generator, enabling
                      X-Ray Generator                                                                                                            XY stage                                         maximum image enlargement.

                     The Xslicer SMX-6010 features a160-kV open tube and can resolve down to 1 micron.
                     Due to the integrated high-voltage transformer, no greasing is necessary.
                     The filament replacement process is simplified by automatic adjustments.
                     Note: 1  m resolution by JIMA chart analysis.
                                                                                                                                                         X-ray generator
                                                                                     Z
                      X-Ray Detector                                X-ray detector        Tilted                                           Vertical CT
                                                                                                                                                                                                  Scanning large circuit boards
                     Equipped with a 3 megapixel flat panel detector.                                                                             Obstructed                                       with vertical CT:
                                                                                                                                                                    Rotary table
                                                                                                                                                                                   X-ray detector
                                                                                                                                                                                                  When the sample is brought near the X-ray
                                                                                       Y                                                    X-ray generator                                       generator to increase the magnification, it
                      Five-Axis Stage                                    Rotated          X                                                                                                       will be obstructed by the X-ray generator
                                                                                                                                                                                                  during CT imaging, making imaging at
                     In addition to the X, Y, and Z axes of the sample stage,                                                                                                                     maximum magnification impossible.
                     the detector tilts and rotates.                     XYZ stage                                                                                   Sample (Large substrate)
                     Five-axis movement supports inspections from any angle.                                                                  Maximum trajectory for the sample
                                                                                                                                                Vertical CT Viewed from above the Rotary Table

                      X-Ray Shield Box

                     The X-rays are well shielded. (Maximum 1  Sv/h external X-ray leakage)                                                Observation Examples
                     The front door lock mechanism prevents the front door from opening during X-ray emission.
                     The interlock mechanism also disables movement of the 5-axis stage when the door is open.
                                                                                                                                        For samples like circuit boards with planer CT, images with a high magnification can be obtained, unlike with orthogonal CT,
                                                                                                                                        which is affected by the width of the sample.

                      Collision Sensor

                     A collision sensor is provided around the X-ray detector to stop the Stage in the event of an emergency (a collision with the
                     sample).



                      Utilities

                     System operation requires only the following: 200 V AC ± 10 %, 1.5 kVA (ground resistance 100   max.)
                     There is no need to provide air or cooling water.










                                                                                                                                                            Vertical CT                             Xslicer SMX-6010

                                                                                                                                                                                                                   Xslicer SMX-6010
        12                                                                                                                                                                                                                Microfocus X-Ray Inspection System  13
   7   8   9   10   11   12   13   14   15   16