Page 6 - Shimadzu Xslicer SMX-6010
P. 6

Simple Operation








                       Switch Smoothly between Fluoroscopy and CT                                                                          Wide CT Imaging Range

                     Switch between fluoroscopy and CT imaging by simply clicking on the menu tab.                                       CT images can be obtained at any position within a 350 mm x 350 mm area. There is no need to move the sample to the center of
                     The Xslicer SMX-6010 features tilted CT imaging. X-ray fluoroscopic images are captured and cross-sectional images are created by   the rotary table as in conventional tilted CT, allowing the scan to be positioned just by clicking on the scanning site.
                     tilting the flat panel detector and rotating it 360 degrees. There is no need to install a separate unit for CT imaging.
                     The CT imaging scan conditions are easy to configure just by selecting the scan mode, scan angle, and scan region.
                     A region of interest in the fluoroscopic image can be observed immediately with a CT scan.












                         Fluoroscopic Image     Simply select the imaging                        CT Imaging
                                                  conditions ([Simple],
                                                [Normal], or [Sharp]) and
                                                  the imaging angle.







                       High-Speed Imaging and High-Speed Reconstruction

                     The calibration procedures are completely automated to speed up the imaging process.
                     Cross-sectional images can be displayed in as little as two minutes after CT imaging starts.                          Set Tracking Points Easily

                                                                                                                                        If a tracking point is set, the observation position of interest when tilted and rotated never leaves the center of the window.
                                                                                                                                        As a result, the point of interest is never lost.
                                                                                                                                        To set a tracking point, simply tilt the detector and double click the position of interest.









                                                                                                                                                                                                                   Tracking point
                                                         7.5 to 20 times higher throughput                                                                                                                         settings value
                                                                                                                                                                                                   Tracking ON
                                                                                                                                                                                          When tilted, the point of interest never
                                                                                                                                                                                  leaves the center of the window because the stage tracks it.



                                                                                                                                                 Not tilted
                                                                                                                                            (The point of interest is
                                                                                                                                              marked with a 〇.)


                                                       15 to 40 minutes
                                                                                                                                                                                                  Tracking OFF
                                                                                                                                                                                   When tilted, the point of interest does not remain at the
                                                                                                                                                                                   center of the window because the stage does not track it.



                                                                                                                                                                                                                   Xslicer SMX-6010