Data Storage on USB Flash Drives  Applications






               Pharmaceuticals and Life Sciences


            The UV-1280 includes programs for enzymatic reaction measurements, and DNA/protein quantitation, essential in
            bioscience/life science fields. A monitor double-beam has been adopted using a highly stable deuterium lamp and halogen
            lamp, which is optimal for kinetics measurements tracking changes over time. With a wealth of accessories, this instrument can
            even accommodate trace samples and measurements as is in test tubes.


            DNA/Protein Quantitation

            Program: DNA/Protein Quantitation
            Easily obtain DNA and protein concentrations, which are measured directly from absorption
            bands in the UV wavelength region, without performing coloring operations. With preset
            wavelengths and computational formulas, simply position the sample and press the
 Using USB flash drives makes it easy to transport analysis data  START/STOP key for one-touch quantitation results. The measurement wavelengths and
            computational coefficients can be freely changed.
 and to store large amounts of data in a PC.  Calculates two-wavelength absorbance ratios and DNA/protein concentrations.
            Select from the following two quantitation formulas*:
 USB flash drives can be connected directly to the UV-1280.
            *Absorbance at 320 nm can be used for background correction.
 Data for spectra and time-course curves can be displayed and saved with   1) A1 = 260 nm absorbance; A2 = 230 nm absorbance
 commercial spreadsheet software.  Absorbance ratio = A1/A2
               DNA concentration = 49.1 × A1 - 3.48 × A2
               Protein concentration = 183.0 × A2 - 75.8 × A1
 UV-1280 + USB flash drive + PC  2) A1 = 260 nm absorbance; A2 = 280 nm absorbance
               Absorbance ratio = A1/A2                        References
 With the UV-1280, the curve-related data (spectra and time-course   DNA concentration = 62.9 × A1 - 36.0 × A2  1.Warburg and Christian, (1942) Biochem. Z. 310, 384-421.
 curves) can be converted to, and saved in,  Protein concentration = 1552.0 × A2 - 757.3 × A1  2.Kalb and Bernlohr, (1977) Anal. Biochem. 82, 362-371.
 CSV format. Transferring this data with USB flash drives allows it to
 be read directly at a PC using commercial spreadsheet software.
            Trace Sample Measurements
 Analysis Compatibility Table                 Spectral measurements of a 100 µL of dsDNA sample were performed using a supermicro cell
                                              holder. A conventional square cell with a path length of 10 mm requires approx. 3.5 mL of
                                              sample. However, a supermicro cell allows measurements with a 100 µL to 200 µL sample.
 Pharmaceuticals and Life Sciences  Foods
                                              Program: Spectrum
                                              Accessories: supermicro cell, supermicro cell holder, and sample compartment unit
 DNA/protein quantitation  Optimal  Pigment measurements  Optimal
 Culture fluid turbidity measurements  Optimal  Quantitation of vitamins, food additives, and minerals  Optimal
 Enzymatic reaction measurements  Optimal


 Environmental                                 Supermicro Cell Holder    Supermicro Cell
 Chemicals
            Culture Fluid Turbidity Measurements
 Turbidity measurements  Optimal
 Transmittance measurements for films  Optimal  Quantitation of total phosphorus and total  Optimal  If the photometric function is used, dilution and other coefficients
 nitrogen in river water, and lakes and marshes  can be calculated automatically. In addition, measure microbial
 Thickness measurements for thin films and other films  Suboptimal  counts as is in test tubes using the test tube holder (special order
 Measurements of plating liquids
 (hexavalent chromium, aluminum, nickel, etc.)  Optimal  product).
            Program: Photometric
 Quantitation of iron, copper, arsenic, and   Optimal  Accessory: Test tube holder
 ammonia in water  The sample compartment unit (P/N 206-60184-07) is separately required.  Test Tube Holder