Page 8 - Shimadzu UV-1280
P. 8

Data Storage on USB Flash Drives                                                                                          Applications






                                                                                                                                         Pharmaceuticals and Life Sciences


                                                                                                                                      The UV-1280 includes programs for enzymatic reaction measurements, and DNA/protein quantitation, essential in
                                                                                                                                      bioscience/life science fields. A monitor double-beam has been adopted using a highly stable deuterium lamp and halogen
                                                                                                                                      lamp, which is optimal for kinetics measurements tracking changes over time. With a wealth of accessories, this instrument can
                                                                                                                                      even accommodate trace samples and measurements as is in test tubes.


                                                                                                                                      DNA/Protein Quantitation

                                                                                                                                      Program: DNA/Protein Quantitation
                                                                                                                                      Easily obtain DNA and protein concentrations, which are measured directly from absorption
                                                                                                                                      bands in the UV wavelength region, without performing coloring operations. With preset
                                                                                                                                      wavelengths and computational formulas, simply position the sample and press the
            Using USB flash drives makes it easy to transport analysis data                                                           START/STOP key for one-touch quantitation results. The measurement wavelengths and
                                                                                                                                      computational coefficients can be freely changed.
            and to store large amounts of data in a PC.                                                                               Calculates two-wavelength absorbance ratios and DNA/protein concentrations.
                                                                                                                                      Select from the following two quantitation formulas*:
              USB flash drives can be connected directly to the UV-1280.
                                                                                                                                      *Absorbance at 320 nm can be used for background correction.
              Data for spectra and time-course curves can be displayed and saved with                                                    1) A1 = 260 nm absorbance; A2 = 230 nm absorbance
              commercial spreadsheet software.                                                                                           Absorbance ratio = A1/A2
                                                                                                                                         DNA concentration = 49.1 × A1 - 3.48 × A2
                                                                                                                                         Protein concentration = 183.0 × A2 - 75.8 × A1
            UV-1280 + USB flash drive + PC                                                                                               2) A1 = 260 nm absorbance; A2 = 280 nm absorbance
                                                                                                                                         Absorbance ratio = A1/A2                        References
            With the UV-1280, the curve-related data (spectra and time-course                                                            DNA concentration = 62.9 × A1 - 36.0 × A2       1.Warburg and Christian, (1942) Biochem. Z. 310, 384-421.
            curves) can be converted to, and saved in,                                                                                   Protein concentration = 1552.0 × A2 - 757.3 × A1  2.Kalb and Bernlohr, (1977) Anal. Biochem. 82, 362-371.
            CSV format. Transferring this data with USB flash drives allows it to
            be read directly at a PC using commercial spreadsheet software.
                                                                                                                                      Trace Sample Measurements
            Analysis Compatibility Table                                                                                                                                Spectral measurements of a 100 µL of dsDNA sample were performed using a supermicro cell
                                                                                                                                                                        holder. A conventional square cell with a path length of 10 mm requires approx. 3.5 mL of
                                                                                                                                                                        sample. However, a supermicro cell allows measurements with a 100 µL to 200 µL sample.
               Pharmaceuticals and Life Sciences                  Foods
                                                                                                                                                                        Program: Spectrum
                                                                                                                                                                        Accessories: supermicro cell, supermicro cell holder, and sample compartment unit
              DNA/protein quantitation                Optimal    Pigment measurements                    Optimal
              Culture fluid turbidity measurements    Optimal    Quantitation of vitamins, food additives, and minerals  Optimal
              Enzymatic reaction measurements         Optimal


                                                                  Environmental                                                                                          Supermicro Cell Holder    Supermicro Cell
               Chemicals
                                                                                                                                      Culture Fluid Turbidity Measurements
                                                                 Turbidity measurements                  Optimal
              Transmittance measurements for films    Optimal    Quantitation of total phosphorus and total  Optimal                  If the photometric function is used, dilution and other coefficients
                                                                 nitrogen in river water, and lakes and marshes                       can be calculated automatically. In addition, measure microbial
              Thickness measurements for thin films and other films  Suboptimal                                                       counts as is in test tubes using the test tube holder (special order
                                                                 Measurements of plating liquids
                                                                 (hexavalent chromium, aluminum, nickel, etc.)  Optimal               product).
                                                                                                                                      Program: Photometric
                                                                 Quantitation of iron, copper, arsenic, and   Optimal                 Accessory: Test tube holder
                                                                 ammonia in water                                                     The sample compartment unit (P/N 206-60184-07) is separately required.  Test Tube Holder

                                                                                                                                                                                                                               UV-1280
      8                                                                                                                                                                                                                       UV-VIS Spectrophotometer  9
   3   4   5   6   7   8   9   10   11   12   13