Page 14 - Shimadzu PDA-7000
P. 14

Options                                                                                                                   Major Specifications






            Options for Sample Preparation                                                                                            Monochromator unit                                 Readout unit
                                                                                                                                       Dispersion system  Paschen-Runge mounting for concave diffraction   Number of light receptors  64 channels max.
                                                                                                                                                     grating                               (channels)
            1. Sampling Mold and Surface Plate  2. FS-3N Belt Grinder           3. L-1000 MM-02 Bench Lathe                            Diffraction grating  Concave radius of curvature: 600 mm  Method of measurement  Single-pulse integration method
             Mold – P/N 210-00005              50Hz ɿ P/N 085-50206-15           P/N 085-50102-02                                                    Number of grooves: 2400 grooves/mm                     Time-resolution PDA photometry
                                               60Hz ɿ P/N 085-50206-16                                                                               Reciprocal dispersion: 0.69 nm/mm
                                                                                                                                       Wavelength range  121 to 481 nm and 589 nm        Data Processing Unit
                                                                                                                                       Evacuation system  Direct-linked rotary pump. Ultimate pressure: 2 Pa
                                                                                                                                                                                          Windows Kit (P/N 211-19209-98)
                                                                                                                                      Excitation Unit                                     Mainly adds the following functions:
                                                                                                                                       Discharge voltage  500 V or 300 V, selectable      1. Report functions Uses ACCESS for analysis results
                                                                                                                                       Discharge frequency  One of three frequencies automatically set for the   Database   ACCESS is a registered Trademark of Microsoft
                                                                                                                                                     discharge conditions. 500 Hz max.     functions    Corporation.
                        Surface plate – P/N 210-00006        three-phase 200V 1150W             single-phase 100V 300W                 Voltage accuracy  Main voltage ± 1%                2. Maintenance   Counter electrode replacement, stand cleaning
                           W300 x D300 x H100mm          W420 x D680 x H830mm, 97kg        W770 x D420 x H360mm, 75kg                                However, input voltage coefficient of variation   Instrument   Management of inlet slit position according to
                                                                                                                                                     within ± 10%                          management   number of discharges
                                                                                Items 1) and 2) below must be ordered                                                                      functions    Management of pump oil replacement and igniter
                                              4. MT-11M Polishing Machine       with the bench lathe.                                  Discharge conditions  6 types                                    cleaning periods
            Consumables                          (for 6 mm dia. tungsten electrodes)  1) O.D. holder (Tip holder)  P/N 085-50102-12    Counter electrode   Automatic regeneration by reversing electrode
                                               P/N 085-50802-01                    TCGCR/L1010F-08                                     cleaning      polarity after each analysis
                                                                                2) Tip (for non-ferrous samples)  P/N 085-50102-13     Spark stand   Stand for argon atmosphere
            1. Tungsten electrode P/N 211-74362                                     TCGT080202FR/L-U KW10
            2. Brush        P/N 211-74965                                       3) Bench lathe stand E-17  P/N 085-50102-11
            3. Pump oil, 1 liter  P/N 017-30159-03                                 Size: W1200 x D600 x H740mm
                                                                                                                                      Installation and Optional Accessories
              Tungsten electrode
                                                             single-phase 100V 110W
                                                          W120 x D210 x H150mm,3kg                                                    Installed Environment                              Gas
                                                    Grinding wheel P/N 085-50802-51                                                   Area Approx. 3 x 2 m min.                          Argon gas : A central supply with switching between at least
                                                                                                                                      Temperature Approx. 10˚C to 28˚C                             two cylinders is convenient.
                                                                                                                                      Humidity 70% RH max.                                         Argon gas purity 99.999% min.
            Standard Samples for Analysis                                                                                             Note  Heat generation approx. 1100 kcal/hour                 Dew point below –70˚C.
            Contact your Shimadzu representative for information on the selection and preparation of standard samples                 The instrument highly resistant to dust and other environmental factors.
            for each analysis purpose. Also consult Shimadzu if chemical analysis is required.                                        However, avoid installing the data processing unit in an environment subject to   Optional Accessories (Require separate installation locations and power supplies.)
                                                                                      ˙Shapes of Cast Aluminum Standard                                                                   Sampling Mold and Surface Plate
                                                                                          Samples                                     vibrations, dust, and strong electrical fields.
                                                                                                                                                                                          L-1000 MM-02 Bench Lathe: single-phase 100V 300W
                                                                                                                                      Power Supply                                        FS-3N Belt Grinder: three-phase 200V 1150W
            ˙ Cast Aluminum Standard Samples
                                                                                                                                       200, 220, 230, or 240 V ± 10%, single-phase, 50/60 Hz, 4.0 kVA  MT-11M Polishing Machine: single-phase 100V 110W
            Cast aluminum standard samples for standardization (disk type), set of 5                                                   Ground: Individually grounded 30 W max. Provide near the rear of   * See the Installation Guide for details.
            (P/N 080-94801-21)                                                                                                         the instrument.
            Standard accessory with PDA-7000, Al base fixed channel.                     Disk type   Pechiney type
            ˙ Cast Iron Standard Samples
                                                                                      ˙Shapes of Cast Iron Standard                   External Dimensions and Weight
            These standard samples are created using Shimadzu's many years of             Samples
            research and experience. They are white pig iron samples of alloy cast iron and normal cast iron, offering highly
            reliable carbon analysis and an adequate concentration range of component elements for optical emission                                                                      PDA instrument   1550 (W) x 620 (D) x 1330 (H) mm
            spectrometry.                                                                                                                                   Wall
            ɾCast iron standard sample for standardization (disk type), set of 3 (P/N 211-72591-92)                                                                   Data               Rotary oil pump    230 (W) x 475 (D) x   253 (H) mm
                                                                                                                                                                      Data
                                                                                                                                                                   processing unit
               One set of 3 supplied as standard accessory with PDA-7000, Fe base fixed channel.                                          620 Pump           Spark   processing unit     Data processing unit    650 (W) x 600 (D) x 1380 (H) mm
            ɾNo. 21 Cast iron standard sample for calibration curves (mushroom type), set of 10 (P/N 210-00004-21)                                Spectrometer  stand        600
                                                                                                                                                                                         (When installed on PC rack.)
                                                                                      Disk type   Mushroom type
                                                                                                                                            240      1550             650                Weight (system)  Approx. 500 kg total
            ˙ Low-alloy Steel Standard Samples                                                                                                                                           Note: The instrument can be mounted against the wall to save space.
                                                                    No. 5 Low-alloy Steel Standard  No.14 Low-alloy Steel Standard                          Vertical rack
                                                                    Samples for Calibration Curves  Sample for Standardization                                                           Maintenance can be conducted from the front.
            These standard samples contain many component elements in concentration ranges                                                                                 Range of movement
            found in actual low-alloy steels.  The concentrations are strictly controlled to ensure                                                                                      The data processing unit can be moved near to the operated instrument.
            high reliability.                                                                                                                      Plan View of Sample Installation   Units: mm
            ɾNo. 14 Low-alloy steel standard sample for                                                                                                                                   Take due care of locations        WARNING
               standardization (disk type), set of 3 (P/N 239-00100)                                                                                                                      where this warning label is    Electric Shock Danger
                                                                                                                                                                                          attached.
               Supplied as standard accessory with PDA-7000, Fe base fixed channel.                                                                                                                                     Danger of electric shocks. Turn
                                                                                                                                                                                                                        off the power before opening
            ɾNo. 5 Low-alloy steel standard sample for calibration curves (disk type), set of 10                                                                                                                            the cover.
               (P/N 210-00004-05)                                   P/N 210-00004-05      P/N 239-00100
                                                                                                                                                                                                                         PDA-7000 Series
      14                                                                                                                                                                                                                    Optical Emission Spectrometer  15
   9   10   11   12   13   14   15   16