Page 6 - Shimadzu MXF-2400
P. 6

Features








              1   The World's First Multi-Channel                        P  S                                                           4   The Effect of Nearby or Interfering            100    Scintillation counter  Kr exatron  Gas flow proportional counter
                  Fluorescent X-ray Spectrometer to be
                                                                                                                                            Elements can be Reduced
                                                                                                                                                                                                                           (5µ polypropylene)
                  Installed with a 4 kW (Thin Window)           1.5                  Mn  Ni  : X-ray intensity  Mo                                                                         80  Kr multitron  Ar exatron  Gas flow proportional
                                                                                                                                                                                                                       counter (6µ Mylar)
                  X-ray Tube                                                                                                          A detector suitable for each element can be selected from between   Counting efficiency (%)  60  Xe exatron
                                                                                                                                      the gas sealed detector sealed with gas appropriate for elements such   Ar multitron       Ne exatron (Al)
            Sensitivity has been enhanced to approximately 1.3 times for heavy                                                        as Ne, Ar and Kr (selection can be made over a broad range from   40      Ne exatron (Be)
            elements and 1.7 times or more for light elements (elements lighter   1.0        : BEC                                    11Na to 92U),                                                        Ne multitron
                                                                                                                                                                                           20
            than Cl).                                                                                                                 the scintillation detector, and the gas flow detector.
                                                                                             : Detection limit                        The effect of nearby or interfering elements can be minimized as the   0  1  2  3  4  5  6  7  8  9  10  11  12
                                                                0.7                                                                                                                       K line
                                                                        15           25          35           45                      optimum detector can be selected to provide excellent detection   BaMo  Cu Fe Cr Ti  Ca K  Cl  S  P  Si  Al  Mg  Na
                                                                                    Atomic Number                                     efficiency and good resolution for each element.    L line  UPbW  CeBa  SnCd  Mo
                                                                                                                                                                                                         Counting efficiency of detectors

              2   Excellent Analytical Accuracy from                            2θ Secondary slit                                           Excellent Measuring Reproducibility for
                  Minute Regional Areas to Whole Areas

            The converging spectrometer system is one of Shimadzu’s original                                                            5   Light Elements                                   100
            designs. The fluorescent X-ray focus doesn't be diverged, and
                                                                                                                                      Using Shimadzu’s original vacuum stabilizer (patented), a constant
            becomes extremely small at the secondary slit so that reflected X-ray
                                                                       Curved crystal                                                 vacuum can be maintained during measuring. And as the change in
            intensity is extremely high, and resolution is good in comparison with
                                                                                                                                      X-ray intensity due to the change in the degree of vacuum (change   Degree of vacuum Pa
            other systems.
                                                                                                                                      due to air absorption) can be suppressed, excellent measuring
                                                                                                                                      reproducibility can be achieved for light elements (such as Al  and Si)       Vacuum stabilizing point
                                                                                                                                      and superlight elements (such as Be, B and C).
                                                                                                                                                                                         Approx. 15                         With vacuum stabilizer
                                                                                        Primary slit                                                                                                                        Without vacuum stabilizer

              3   Excellent Long-term Stability and                                                                                                                                                        The point of starting analysis  Time (sec.)
                  Maintenance-free Characteristics

            Through the development of original technology by Shimadzu an
            excellent gas sealed detector (SPC) is used to obtain long-term stability   Exatron for detection of
                                                                           heavy and light elements
            and maintenance-free characteristics over a wide range (11Na to 92U) of                                                         Excellent Long-term Stability for
            light elements including Na which normally only could be analyzed                                                           6   Superlight Elements (Be, B, C, N, O, F)
            using a gas flow detector (FPC).
            Shimadzu’s own original gas sealed detector has the following                                                             The gas flow detector (FPC) has excellent long-term stability as pulse
            features.                                                                                                                 height distribution is stabilized through the use of an automatic core
            1) Starting up X-ray signals is fast, and a large number of X-ray signals                                                 wire winding system (Shimadzu patent) and a gas density stabilizer
              can be counted at a high speed.                                                                                         with CPU control system.
            2) CO2 is mixed in with the inert gases (Ne, Ar, Kr) to give good gas                                                     The automatic core wire winding system is different to the previous
                                                                     Multitron for detection of   Scintillation counter for
              stability, and the core wire does not become contaminated as there   heavy elements  heavy elements                     core wire cleaning system and manual core wire winding system in
              is no resolution deterioration due to ionization.                                                                       that core wire winding is continuously automatic (5 mm per day) so
            3) As there is no gas piping, consideration of the surroundings is not   %  CaO    Statistical error 1σ (C.V. 0.084%)     that the core wire does not become contaminated, analysis can be
                                                                      Concentration
                                                                 +0.4     44.7%                                                                                                                       Anode          Window for X-rays
              required, and excellent long-term stability is assured. (The device is   +0.2              0.084%                       conducted always with a new core wire, and maintenance is not
                                                                  0
              ideal for process control and automatic analysis as the number of   –0.2                                                needed.
                                                                 –0.4
              calibration curve adjustments and α/βcorrection can be minimized.)                                                      Furthermore, the PR gas flow and density necessary for the gas flow
            4) As the gas is sealed in the device, there is no maintenance, which   %  Fe2O3   Statistical error 1σ (C.V. 0.22%)      detector achieves stability in the gas density stabilizer with CPU   PR gas
                                                                      Concentration
              makes the product extremely permanent. Moreover, the whole   +0.8  2.1%                     0.22%                       control system.
                                                                 +0.4
              spectrometer unit is kept stable as a thermostat in the device   0
                                                                 –0.4
              continually maintains the temperature to within ±0.2°C of the set   –0.8
                                                                                                                                                                                                        New core wire  Used core wire
              temperature.                                         (C.V)  1st day  5th day  10th day  15th day  20th day  25th day  30th day
                                                                                                                                                                                                                            MXF-2400
                                                                                                                                                                                                                     Multi-Channel X-ray Fluorescence Spectrometer
   1   2   3   4   5   6   7   8   9   10   11