Page 24 - Shimadzu IRTracer-100
P. 24
Infrared Microscope AIM-9000 (P/N 206-32000-58 (Narrow band MCT))
The AIM-9000 incorporates a bright, optimized optical system and a high-sensitivity MCT detector. Not only enabling high-sensitivity
measurement of micro samples, but the system has also been automated to ensure all steps involved in micro analysis can be
performed quickly and easily.
Features of the AIM-9000
Incorporates a bright, optimized optical system and a high-sensitivity MCT
detector to enable high-sensitivity measurement.
Enables re ection/ATR measurements on samples up to 40 mm thick.
Comes with a digital zoom function of up to 330× magni cation using the
wide-view camera (optional) and the microscope camera. Enables the
measurement position to be quickly determined.
Includes an automatic contaminant recognition system that automatically
determines the measurement position as a standard feature.
Up to 60 measurement position can be recorded.
Includes a contaminant analysis program to identify the cause of failures as a
standard feature.
Note: In order to use this attachment, an external beam extraction kit (P/N 206-32570-42), an AIM connection kit Minute
(P/N 206-32607-42), and accessories for the AIM-9000 (P/N 206-32799-xx) are required. Samples
ATR Objective (Ge prism: P/N 206-32600-41)
This objective lens is used when performing ATR measurements with the AIM-9000
infrared microscope. Using a cone-type prism, this single re ection objective features 15×
magni cation and a 45-degree mean incident angle. The
Minute
slide-on type prism makes it easy to switch back and forth Samples
between visible observation and infrared measurement.
Mapping Program (AIMsolution) (P/N 206-32936-41)
The mapping program measures the absorption distribution on the surface of a sample and creates imaging data when used with the
Shimadzu AIM-9000 infrared microscope.
It allows setting of mapping parameters, such as the mapping range, the scan intervals, and the background positions, on the composite
visible images. It also supports area mapping and random mapping modes. In addition to mapping in the conventional transmittance and
re ectance modes, micro-ATR mapping is also available. (An optional ATR objective is required. It also requires a separate pressure sensor.)
From the acquired mapping data, it is possible to extract spectra and to perform calculations for speci c peaks and functional group
mapping by multivariate analysis.
5-cm Gas Cell (P/N 202-32006-xx)
10-cm Gas Cell (P/N 202-32007-xx)
Long-Path Gas Cell
Gas cells are used for analysis of gas samples, and the path length is selected
based on the concentration of the samples. Gas cells with short path lengths of
5 or 10 cm and long path lengths of 10 m or more are available. Please contact
your Shimadzu representative for details on long-path gas cells.
5-cm Gas Cell
Gases Long-Path Gas Cell