Page 14 - Shimadzu GCMS-TQ8040 NX
P. 14

Smart Database Series Enables Accurate Analysis Using MRM                                                             Quick-DB Forensic Toxicology Database
                     GC-MS/MS database series specialized for various fields supports your analysis with ease and accuracy. These databases contain   This database contains information on sample preparation, data acquisition, and analysis of 68
                     pre-optimized MRM transitions and collision energies required for GC-MS/MS analysis, allowing users to start an analysis   compounds often involved in poisonings. Due to the simple QuEChERS method used for the sample
                     immediately just by using the AART function to automatically modify the retention times.                           preparation, even first-time users can pretreat samples easily. The performance control function,
                                                                                                                                        which automatically assesses the system status, quickly determines problematic areas. As a result,
                       Smart Pesticides Database ™                   Smart Metabolites Database ™                                       users can analyze toxicological substances while consistently maintaining the highest status level.
                                                                                                                                        Using a Calibration Curve for a Pretreated Sample
                     It covers the pesticides (530 compounds)      The database contains 627 compounds
                     subject to GC-MS analysis and used            including metabolites contained in food,                             to Correct for Recovery Rates
                     inside and outside Japan. The database        blood, urine and cells. It also contains                             By using the calibration curve information from a pretreated sample,
                     also contains information on compounds        information on the stable isotopes of 38                             accurate quantitative values can be obtained. The calibration curve   If specific control parameter criteria are not
                     that can be used as internal standards.       major metabolites, which can be used as                              information is used to correct differences in recovery rates for each   satisfied, the optimal steps for restoring the
                     Therefore, it also supports analysis with     internal standards.                                                  target compound or correct for effects caused by adsorption, which   system status are displayed in a message box.
                     the internal standard method.                                                                                      occurs when creating calibration curves using standards.

                       Smart Aroma Database  ™                       Smart Forensic Database ™                                                           Effect of
                                                                                                                                                         pretreatment
                     511 compounds that contribute to              The database is registered with 486                                                   recovery rate
                     aroma are registered in the database.         forensic toxicological substances often
                     This database supports various aroma          involved in poisonings, such as drugs of
                     analysis, such as detecting aroma             abuse, psychotropic drugs,                                            Calibration curve for
                     compounds from scan measurements              pharmaceuticals, and pesticides.                                      whole blood sample       Less affected by adsorption
                     and high-sensitivity target analysis using                                                                          spiked with standard     caused by matrix effects
                     MRM and SIM.                                                                                                        and pretreated                                       Quick-DB Forensic  Launcher Screen

                       Smart Environmental Database ™
                     The database contains information on                                                                                  Off-Flavor Analyzer
                     527 compounds including                                                                                            This analysis system contains information on the major odor-causing substances
                     polychlorinated biphenyl, brominated                                                                               identified from previous problems and associated sensory information, thus enabling
                     flame retardants, dioxins, polycyclic                                                                               the reliable identification of odor-causing substances. It allows users to calculate
                     aromatic hydrocarbons, and                                                                                         quantitative values easily without using standard samples, and to identify
                                                                                                                                                                                                                   Sensory
                     organochlorine pesticides, as well as                                                                              odor-causing substances through comparison with registered odor thresholds. The   Primary odor GC/MS analytical  information
                                                                                                                                                                                               components
                                                                                                                                                                                                         conditions
                     their stable isotope labeled compounds.
                                                                                                                                        system also supports the use of a sniffer, enabling the efficient confirmation of
                                                                                                                                        odors using the predicted retention time display function.
                                                                                                                                        In addition, support is provided for a total system, including pretreatment units such
                     Quick-DB  Series Enables Quick Screening Without Using Standards                                                   as HS, SPME, and thermal desorption units using MonoTrap .
                                 ™
                                                                                                                                                                            ™
                     Preregistered with calibration curve information from the internal standard methods, this database allows users to calculate quantitative values   Comparison of Concentration to Odor Threshold Values
                     without analyzing standard samples. It can be used for screening when quick confirmation of quantitative results is required.
                       Quick-DB GC/MS Residual Pesticides Database
                     The database contains information on calibration curves created using
                     pesticide surrogates as the internal standards, thus enabling the simultaneous
                     screening of 491 residual pesticides without using standard samples. The
                     registered calibration curves have been created by grouping target pesticides
                     based on similar behavioral and physical properties, and allocating pesticide
                     surrogates with similar physical properties to each group as internal standard
                     substances. This allows highly accurate quantitative values to be calculated.                                                                                    Since some odor components have a low odor threshold, low
                                                                                                                                         Odor-causing substances can be identified through comparisons of   concentration levels need to be detected to identify the causative
                     Allocation of Pesticide Surrogates                                                                                  odor thresholds with the concentrations of off-flavor components   substances. High-sensitivity MRM/SIM analysis by GC-MS(/MS) can reliably
                     Based on Physical Properties of Target Pesticides                                                                   identified in a chromatogram.                 detect even trace components near the odor threshold (a few pg/g).
                                                                      Sensitivity Variation Adjustments Using Pesticide Surrogates                                                                           1.5
                     Target pesticides             Pesticide surrogates                                                                                                                 4.0  195.0              195.0 > 167.0
                                                                                                                                                                                                                210.0 > 195.0
                                                                                                                                                                                           210.0
                                                                          Pesticide
                                                                          Pesticide                                                                                                     3.0  167.0           1.0 210.0 > 167.0
                                                       Group 1                               Pesticide
                                Analytical                                                                                                 Under Threshold Value  Over Threshold Value  2.0
                                behavior              Dichlorvos-d             IS IS              IS                                                                                    1.0                  0.5
                                                                               (Pesticide-d)
                         Polarity         Boiling                              (Pesticide-d)      (Pesticide-d)                           Benzophenone          2,4,6-Tribromophenol
                                          point        Group 2                                                                                                                          0.0
                               Malathion              Acephate-d                                                                          Concentration/Threshold=Odor threshold value  Concentration/Threshold=Odor threshold value  17.50  17.75  18.00  18.25  17.50  17.75  18.00  18.25
                                                                                                                                                                                            Mass Chromatograms of 2,4,6-Trichloroanisole
                       Recovery          Others                         Database Calibration Curve  Customer's GC-MS                          2.543/10.000=0.254  2241.933/100.000=22.419  (estimated concentration of 18.166 pg/g) in Food with an Odd Odor
                         rate
                                                       Group 4        Pesticide surrogates can also be used to adjust differences in                                                          (Left: Scan analysis, Right: MRM analysis)
                              Hydrophobicity          Iprobenfos-d    target pesticide responses observed in calibration curves and a
                                                Allocation            customer's instrument due to variations in GC-MS(/MS) sensitivity.
        14                                                                                                                                                                                                                                  15
   9   10   11   12   13   14   15   16   17   18   19