Smart Database Series Enables Accurate Analysis Using MRM  Quick-DB Forensic Toxicology Database
 GC-MS/MS database series specialized for various fields supports your analysis with ease and accuracy. These databases contain   This database contains information on sample preparation, data acquisition, and analysis of 68
 pre-optimized MRM transitions and collision energies required for GC-MS/MS analysis, allowing users to start an analysis   compounds often involved in poisonings. Due to the simple QuEChERS method used for the sample
 immediately just by using the AART function to automatically modify the retention times.  preparation, even first-time users can pretreat samples easily. The performance control function,
               which automatically assesses the system status, quickly determines problematic areas. As a result,
 Smart Pesticides Database ™  Smart Metabolites Database ™  users can analyze toxicological substances while consistently maintaining the highest status level.
               Using a Calibration Curve for a Pretreated Sample
 It covers the pesticides (530 compounds)   The database contains 627 compounds
 subject to GC-MS analysis and used   including metabolites contained in food,   to Correct for Recovery Rates
 inside and outside Japan. The database   blood, urine and cells. It also contains   By using the calibration curve information from a pretreated sample,
 also contains information on compounds   information on the stable isotopes of 38   accurate quantitative values can be obtained. The calibration curve   If specific control parameter criteria are not
 that can be used as internal standards.   major metabolites, which can be used as   information is used to correct differences in recovery rates for each   satisfied, the optimal steps for restoring the
 Therefore, it also supports analysis with   internal standards.  target compound or correct for effects caused by adsorption, which   system status are displayed in a message box.
 the internal standard method.  occurs when creating calibration curves using standards.

 Smart Aroma Database ™  Smart Forensic Database ™  Effect of
                               pretreatment
 511 compounds that contribute to   The database is registered with 486   recovery rate
 aroma are registered in the database.   forensic toxicological substances often
 This database supports various aroma   involved in poisonings, such as drugs of
 analysis, such as detecting aroma   abuse, psychotropic drugs,   Calibration curve for
 compounds from scan measurements   pharmaceuticals, and pesticides.  whole blood sample  Less affected by adsorption
 and high-sensitivity target analysis using   spiked with standard  caused by matrix effects
 MRM and SIM.  and pretreated                                       Quick-DB Forensic  Launcher Screen

 Smart Environmental Database ™
 The database contains information on   Off-Flavor Analyzer
 527 compounds including   This analysis system contains information on the major odor-causing substances
 polychlorinated biphenyl, brominated   identified from previous problems and associated sensory information, thus enabling
 flame retardants, dioxins, polycyclic   the reliable identification of odor-causing substances. It allows users to calculate
 aromatic hydrocarbons, and   quantitative values easily without using standard samples, and to identify
                                                                                         Sensory
 organochlorine pesticides, as well as   odor-causing substances through comparison with registered odor thresholds. The   Primary odor GC/MS analytical  information
                                                                               conditions
                                                                     components
 their stable isotope labeled compounds.
               system also supports the use of a sniffer, enabling the efficient confirmation of
               odors using the predicted retention time display function.
               In addition, support is provided for a total system, including pretreatment units such
 Quick-DB  Series Enables Quick Screening Without Using Standards  as HS, SPME, and thermal desorption units using MonoTrap .
 ™
                                                  ™
 Preregistered with calibration curve information from the internal standard methods, this database allows users to calculate quantitative values   Comparison of Concentration to Odor Threshold Values
 without analyzing standard samples. It can be used for screening when quick confirmation of quantitative results is required.
 Quick-DB GC/MS Residual Pesticides Database
 The database contains information on calibration curves created using
 pesticide surrogates as the internal standards, thus enabling the simultaneous
 screening of 491 residual pesticides without using standard samples. The
 registered calibration curves have been created by grouping target pesticides
 based on similar behavioral and physical properties, and allocating pesticide
 surrogates with similar physical properties to each group as internal standard
 substances. This allows highly accurate quantitative values to be calculated.  Since some odor components have a low odor threshold, low
               Odor-causing substances can be identified through comparisons of   concentration levels need to be detected to identify the causative
 Allocation of Pesticide Surrogates   odor thresholds with the concentrations of off-flavor components   substances. High-sensitivity MRM/SIM analysis by GC-MS(/MS) can reliably
 Based on Physical Properties of Target Pesticides  identified in a chromatogram.  detect even trace components near the odor threshold (a few pg/g).
 Sensitivity Variation Adjustments Using Pesticide Surrogates                      1.5
 Target pesticides  Pesticide surrogates                       4.0  195.0             195.0 > 167.0
                                                                                      210.0 > 195.0
                                                                 210.0
 Pesticide
 Pesticide                                                     3.0  167.0          1.0 210.0 > 167.0
 Group 1  Pesticide
 Analytical      Under Threshold Value  Over Threshold Value   2.0
 behavior  Dichlorvos-d  IS IS  IS                             1.0                 0.5
 (Pesticide-d)
 Polarity  Boiling  (Pesticide-d)  (Pesticide-d)  Benzophenone  2,4,6-Tribromophenol
 point  Group 2                                                0.0
 Malathion  Acephate-d  Concentration/Threshold=Odor threshold value  Concentration/Threshold=Odor threshold value  17.50  17.75  18.00  18.25  17.50  17.75  18.00  18.25
                                                                  Mass Chromatograms of 2,4,6-Trichloroanisole
 Recovery  Others  Database Calibration Curve  Customer's GC-MS  2.543/10.000=0.254  2241.933/100.000=22.419  (estimated concentration of 18.166 pg/g) in Food with an Odd Odor
 rate
 Group 4  Pesticide surrogates can also be used to adjust differences in   (Left: Scan analysis, Right: MRM analysis)
 Hydrophobicity  Iprobenfos-d  target pesticide responses observed in calibration curves and a
 Allocation  customer's instrument due to variations in GC-MS(/MS) sensitivity.
 14                                                                                                               15
   10   11   12   13   14   15   16   17   18   19   20