Page 16 - Shimadzu GCMS-TQ8040 NX
P. 16

Enhanced Support System for Data Management
                     Qualitative Analysis Using GC-MS/MS                                                                                LabSolutions  DB/CS Realizes Complete Data Integrity*
                                                                                                                                                      ™





                     GC-MS/MS allows users to freely select ions cleaved by electron ionization (EI), and then cleave precursor ions via collision
                     induced dissociation (CID), thus enabling the detailed analysis of partial structures. A product ion scan can be used to easily
                     discriminate structural isomers and regioisomers, which are hard to identify with an EI mass spectrum obtained via GC/MS.
                     This mode is optimal for predicting partial structures.

                                                                                        EI-Product Ion Scan
                                                         EI-Scan
                      Example of Structural Isomers                                     (Precursor m/z 126)
                                              %                                   %
                                           100                    126          100                   126
                                            75                                 75
                                                                                                97
                                            50                                 50            84                                         LabSolutions DB/CS is the integration software for analytical instruments that complies with regulations regarding electron-
                                            25            84                   25    42  55  69
                                                  43  55  69  77  98               30                                                   ic records and signatures, such as "FDA 21 CFR Part 11" and "ER/ES guidelines".
                                            0
                             α-PVP            25   50   75   100  125  150      0  25  50  75   100  125  150                           Data management with LabSolutions prevents overwriting or deleting analysis data. It also offers a complete suite of
                                              %                                   %
                                            100                   126          100                   126                                advanced security features to provide an optimal solution for data integrity.
                                            75                                 75
                                            50                                 50    41
                                                                                          69                                            Network System: LabSolutions CS
                                            25                                 25       55
                                                  43  55  69 77 84  105            30        84   96
                                             0                                  0
                       α-PBP Piperidine analog  25  50  75   100  125  150       25   50   75   100   125   150                         Data acquired from multiple systems can be reviewed or confirmed using client computers connected via a LAN or other
                                                                                                                                        network. If multiple systems are used, data obtained from each system can be reviewed from any client
                                                                                        EI-Product Ion Scan
                                                         EI-Scan                                                                        computer. Even in the case of multiple analysts using the same system, the ability to separate analytical work from measure-
                       Example of Regioisomers                                          (Precursor m/z 149)
                                              %                                   %
                                           100     58                          100             121                                      ment work improves work efficiency.  *2                            *3
                                                                                                                                                              Client PC       Laboratory or office      iPad    LabSolutions server
                                            75                                  75
                                                                                                   149
                                            50                                  50     65
                       Methylone (bk-MDMA)  25                                  25
                                                    65   91   121   149                    91
                                             0               135                0
                                                  50     100    150    200           50     100    150    200
                                              %                                   %
                                                   58                                  65
                                           100                                 100
                                            75                                  75                 149
                                                                                                                                            Acquisition
                                            50                                  50                                                         controller PC  *1
                                                                                               121
                                            25                                  25
                        2,3-Methylenedioxy-  0      65   91   121  135  149     0        77   93
                          methcathinone
                                                  50     100    150    200           50     100    150    200
                                                                                                                                                                                                  Thermal
                                                                                                                                             LC   GC     GCMS       LCMS    ICMPS  UV   FTIR  RF        PPSQ ™  Balance  Agilent LC Agilent GC
                                                                                                                                                                                                  analyzer
                       High-Speed Scan Control Technology
                       Advanced Scanning Speed Protocol (ASSP )
                                                                          ™
                                          Equipped with a function to automatically optimize the rod bias voltage during high-speed data
                                          acquisition, the system can collect data stably through scans as well as product ion scans at
                                          20,000 u/sec (patent: US6610979).
                                                                                                                                                                                    Powder and
                                          With the GCMS-TQ8040 NX, ten or more product ion scans can be configured for a single                  AA                 TOC            particle size analyzer  EDX       CBM-201m Other Vendor
                                          measurement, and three or more user-specified analysis modes (Scan, MRM, product ion scan)                                                                                       LC/GC
                                          can be combined.                                                                                        Combine with Multi-Data Registration license to enable integrated management of these instruments’ data.  File acquisition capable
                     Newly Patented Technology (ASSP)                                                                                   *1 The acquisition control PC controls analytical instruments. It can also be used to send analytical instructions and perform postrun analysis, just like a client PC.
                                                                                                                                        *2 If a terminal service is used, then LabSolutions software does not need to be installed on client PCs.
                                 Diazinon                                                                                               *3 If an iPad is used, then XenApp from Citrix must be installed.
                     Propyzamide
                                                                                                                                        Standalone Database System: LabSolutions DB
                     Black: 1,111 u/sec
                     Red: 5,000  u/sec
                     Blue: 10,000 u/sec                                                                                                 LabSolutions DB manages data by connecting a computer with analysis instruments, which do not have network connections. It is
                                                                                                                                        recommended for facilities that do not require network connections and want to be ER/ES compliant with one computer.
                                                                                                                                        *LabSolutions DB/CS is optional software that provides enhanced data integrity support. Some analysis systems and functions are not supported in contrast to the standard
                                                                                                                                          workstation software GCMSsolution.


        16                                                                                                                                                                                                                                  17
   11   12   13   14   15   16   17   18   19   20