Page 8 - Shimadzu GC-2014
P. 8

Flexibility
            Expandability to Support all Types of Analysis

            For varied and complicated analyses, an array of units and detectors provide quick, easy solutions


            A Full Line of Injection Units                                                                                            Compact, High-Sensitivity Detectors

            Obtaining better data requires that the appropriate   analyzed. With the GC-2014, the optimum injection                   The TCD employs the highly regarded semi-diffusion TCD cell of the GC-14 Series.
            column and sample introduction method be selected   mode can be selected from four types of injection units.              High-selectivity detectors offer superb sensitivity realized by further improving the technology used in the GC-2010 detectors.
            according to analytical objectives and samples to be
                                                                                                                                      Flame Ionization Detector                                                                                                Flame Thermionic Detector
            Dual Packed                                        Split/Splitless                                                             FID-2014                                                                                                                FTD-2014C
            Injection Unit                                     Injection Unit
                 DINJ-2014                                          SPL-2014                                                          Automatic ignition and re-ignition functions are standard. By mounting an APC                                            This specialized capillary-type detector employs the FTD-2010
                                                                                                                                      or solenoid valve unit, a feedback function cuts off gas supply when the                                                 mechanism. Used for analysis of organic nitrogen compounds and
                                                                                                                                      hydrogen  ame is extinguished. Generally used for detection of organic                                                   organic phosphorus compounds such as residual pesticides.
            Designed for Dual FID and TCD                      Standard unit for high-speed
            analyses.                                          analysis with a narrow bore                                            compounds with a hydrogen carbon bond.                                                                                   The new collector construction allows replacement without tools.
            Because two  ow paths are                          column.                                                                An optional  ame monitor is available.                                                                                   An optional alkali source regeneration kit recoats the bead
            handled using one                                  The gas saver function restricts                                       Single and dual FID’s are available.                                                                                     reducing running costs.
            temperature control port,                          the total gas used.
            these count as one heated                          High-pressure injection
            zone.                                              standard                                                               Thermal Conductivity Detector
                                                                                                                                                                                                                                                                                           *Collector replacement
                                                                                                                                           TCD-2014                                                                                                                                          requires no tools.
            Single Packed                                      Direct Injection
            Injection Unit                                     Unit                                                                   The TCD-2014 is a semi-diffusion type cell reducing contamination and increasing
                                                                                                                                      cell lifetimes. Incorporates an automatic  lament protection circuit. The TCD-2014                                       Flame Thermionic Detector
                 SINJ-2014                                          WBI-2014                                                          is used for analysis of inorganic gases and concentrated organic compounds.
                                                                                                                                                                                                                                                                    FTD-2014
            This is a specialized sample                       Incorporates a septum purge
            injection unit for use with ECD                     ow path to restrict solvent                                           Electron Capture Detector                                                                                                Packed column analysis is supported by the FTD- 2014 using the
            or other high sensitivity                          tailing.                                                                                                                                                                                        FTD-14 mechanism and collectors from both the FTD-14 and -17.
            detectors.                                         Sharing glass inserts with                                                  ECD-2014
                                                               splitless analysis simpli es
                                                               parts requirements (patented).                                         This cell is very similar to the ECD-14; so spare radiation sources can be shared.
                                                                                                                                      This detector is used for analysis of electrophillic compounds. Improved cell
                                                                                                                                      insulation and reduces contamination achieving higher sensitivity.
                                                                                                                                                                                                                                                               Optional Units
               Simultaneously Mount up to                                                                                              CAUTION
               Three Injection Units and Four Detectors                                    Top of GC-2014                              The ECD uses a radioactive Ni63 source. Special governmental registration is required to                                A variety of options support various types of analyses
                                                                                                                                       use or purchase it. Please check with your local Shimadzu representative for relevant
                                                                                                                                       regulations in your area.
               Select from four types of injection units and  ve types of detectors according
                                                                                                                                                                                                                                                               AOC-20 Series                          SystemGC
               to the target compounds and analysis objective. Modular injection units,
               detectors and auto-injectors can be easily added after installing the unit in   Detector mounting site                                                                                                                                          The AOC-20i auto injector              A sub-door is included for
                                                                                                                                      Flame Photometric Detector
               your lab.                                                                                                                                                                                                                                       and AOC-20s auto sampler               SystemGC products. The column
                                                                                                                                           FPD-2014                                                                                                            is used with the GC-2014.              oven door is separated into the
                                            Flexibility                                  7         8 9                                The FPD-2010, the nozzle system was updated to provide support for packed                                                Varying the parameters of              column and sub door. The sub-door
                                                                                                                                                                                                                                                                                                      can accommodate three
                                                                                                                                                                                                                                                               sample injection sets the
                      Unit Addition                                                      1  5  2  6  3  4                             column analysis while maintaining its high sensitivity. The ability to exchange                                          optimal injection mode.                temperature-controlled valves, and
                                                  Options after Installation  OPTION      1  2  3  4                                  nozzles optimizes both packed column and capillary column analyses.                                                      This high level of precision           the left-side panel three valves that
                  4 types of injection units                                                                                          The FPD-2014 is compact with a high maximum temperature (350°C). This                                                    and repeatability is not               are not temperature-controlled.
                                                  Injection units / Detectors                                                                                                                                                                                  possible with manual                   The PRG-2010 is used to control
                                                  Auto-injectors                      Injector mounting site                          detector is used for analysis of organic sulphur compounds and organic
                    5 types of detectors          Various options can be added                                                        phosphorus compounds such as residual pesticides and malodorous components.                                              injection.                             these valves.
                                                                                                                                                                                                                                                                                                      SystemGC’s are custom order
                                                                                                                                                                  *Filter replacement requires                                                                                                        products. For details, contact your
                                                                                                                                                                    no tools.
                                                                                                                                                                                                                                                                                                      Shimadzu representative.

                                                                                                                                                                                                                                                                                                                                            GC-2014
      8                                                                                                                                                                                                                                       9                                                                                      Capillary and Packed Gas Chromatograph  10