Easy Operation
            Easier to understand, simpler operation

            Large display, help functions and pop-up screens Loaded with productivity-enhancing functions


                                              Large display
                                              shows most analysis details at a glance,                                                Reduces unexpected downtime
                                              ideal for Chromatopac users.                                                            Intelligent Self-diagnostics

                                              A large LCD displays chromatograms and method parameters.                               Self-diagnostics validate that the instrument before injection.
                                              This is a great improvement for  Chromatopacs systems that do not have                  This function conducts a detailed diagnosis of the
                                              these real time displays.                                                               septum and glass insert operating lifetime, temperature sensor
                                              Graphical user interface enables quick setting of all analytical conditions.            errors, supplied gas pressure, control status for each gas,
                                              The built-in Help function almost eliminates need for familiarization training.         ignition operation, DC voltage and AD converter.
                                                                                                                                      Regular diagnosis prevents unexpected downtime.
                                                                                                                                                                                                 Self-diagnostics

                                                                                                                                                                                                Unit control check
                                                                                                                                                                                                Hardware diagnosis
                                                                                                                                                                                                Save and check diagnosis log
                                                                                                                                      Digital Control of Column Flow Rate and Split Ratio
                                                                                                                                      AFC (Advanced Flow Controller)


                                                                                                                                      Using the electronic  ow controller, the column inlet pressure,
                                                                                                                                      column  ow rate, linear velocity and split ratio are easily
                                                                                           Large Display                              digitally set. Flow meters have now become obsolete. It is no
                                                                                                                                      longer necessary to set  ows with soap- lm  ow meters.
                                                                                           Chromatogram display
                                                                                           Graphical U/I                              No longer required to adjust complicated split ratio settings by
                                                                                           Built-in Help Function
                                                                                                                                      measuring the split or column  ows manually.









                                              Polarity display prevents injection errors
                                              Easy-to-understand                                                                      Digital Control also for Packed Column Analysis
                                              Pop-up Screens                                                                          Dual AFC

                                              Graphical popup screen that clearly                                                     Easy setting of carrier gases  ow by the electronic  ow
                                              indicates the polarity so manual injection                                              controllers (AFC) for both capillary and packed column analyses.
                                              errors are prevented when using the dual                                                For control of detector gas, select between Advanced Pressure
                                              packed column system.                                                                   Controller (APC) and low cost manual  ow controllers.
                                                                                                                                      When manual  ow controllers are used, a solenoid valve
                                                                                                                                      automatically turns ON/OFF the detector gas when the main
                                                                                                                                      unit power or detector is turned ON/OFF.