Page 11 - Shimadzu GC-2014
P. 11
Flexibilty Application Systems
Effective Use of GC Series Column Resources GC-2014 Analysis Systems for Every Application Speci cations
Effective use of valuable column resources is maintained by using the 40-mm-pitch Headspace Analysis System
glass column the same as Shimadzu GC-7, 9, 12, 14, 15 and 16 Series.
• High reproducibility ensure reliable quantitation for volatile component Column Oven Detectors
analysis. Temperature range (Ambient + 10°C) ~ 400°C (using liquid CO2 gas*: -50°C ~400°C) Temperature range 400°C max. (FID, TCD, ECD, FTD) 350°C max. (FPD)
Large Column Oven Facilitates System Con guration Dimensions 250 (W) × 360 (H) × 175 (D) mm Temperature setting 1°C steps
• GC-2014 + HS-10
No. of units installed simultaneously
Up to 4 units (restricted depending on detector type)
15.8L
Oven capacity
Column Operations Analysis Applications Temperature accuracy Set value (K) ± 1% (calibration at 0.01°C increments) Detector type FID, TCD, ECD, FPD, FTD for capillary/packed
• Measurement of VOCs in water Temperature deviation 2°C max. (on 200mm dia. circumference 30mm from rear) Flame Ionization Detector (FID)
Column replacement is easier by increasing the • Blood Alcohol Concentration (BAC) Temperature variation coef cient 0.01°C/°C System Dual ow rate differential system
oven capacity while keeping its width the same. Temperature program steps Up to 20 (cooling program possible) Temperature range 400°C max.
Programmed rate setting range -250°C ~ 250°C/min Minimum detected quantity 3pgC/s (dodecane)
Simulated Distillation GC System for LabSolutions
Total time for all steps 9999.99 minutes max. Dynamic range 10 7
• Measures the boiling point distribution of petroleum distillate using the Linear heating range Up to 150°C: 30°C/min (100V/120V), 60°C/min (230V) Nozzle Quartz glass Standard: for packed, Option: for capillary
relationship between retention time and boiling point. Up to 250°C: 20°C/min (100V/120V), 40°C/min (230V) Thermal Conductivity Detector (TCD)
• Analyzes distillation characteristics and prints specialized reports. Up to 380°C: 10°C/min (100V/120V), 20°C/min (230V) Dual ow rate differential system
Up to 400°C: 7°C/min (100V/120V), 15°C/min (230V) System
GC-2014 System Con guration *at 25°C ambient temperature Temperature range 400°C max.
• GC-2014 + WBI-2014 + LabSolutions GC + Simulated Distillation GC Analysis Software
250mm (Select sample injection unit and column according to the target sample) Cooling rate 300°C ~ 50°C in 6 min max. (at 25°C ambient temperature) Dynamic range 10 5
Columns accepted Capillary columns: 2 Sensitivity 40,000mV · mL/mg (built-in pre-ampli er, with 10 × ampli cation)
GC-14 Analysis Applications Packed columns for GC14B: 4 (Glass columns: 2) Electron Capture Detector (ECD)
• Petroleum distillate
63
230mm *Optional parts are required to use liquid CO2 gas. System Fixed current system using Ni370MBq radiation source
Temperature range 400°C max.
PONA Analysis System Sample Injection Unit Minimum detected quantity 0.1pg/s (γ-BHC)
• Separates gasoline or other hydrocarbon compounds, identi es the peaks Temperature range Up to 400°C Dynamic range 10 4
and classi es them by carbon number, or by type (paraf n, ole n, Heating settings 1°C steps Flame Photometric Detector (FPD)
Packed Column Capillary Column naphthene and aromatic series) for quantitation. No. of units installed simultaneously Up to 3 units Temperature range 350°C max.
Accommodates both packed and capillary columns. System Con guration Sample injection unit types Dual packed, single packed, split/splitless, direct, direct (AMC) Dynamic range P: 10 4
• GC-2014 + CRG-2014 + GCsolution + PONAsolution S: 10 3
+ MS Excel (commercially available spreadsheet software) Carrier Gas Flow Controller Minimum detected quantity P: 0.5pgP/s (tributyl phosphate)
(Select sample injection unit and column according to the target sample)
For Packed / Dual S: 8pgS/s (dodecane thiol)
Analysis Applications Flow rate setting range 0 ~ 100mL/min Flame Thermionic Detector (FTD)
Select Your Flow Controller Combination • Categorization of naptha, gasoline and gasoline-based materials by carbon number or type Programmable steps 7 (Two types, one for capillary and one for packed. The speci cation are the same.)
and their quantitation.(Also offers calculation of mean speci c gravity, mean molecular
weight, and octane value.) Programmed rate setting range -400 ~ 400mL/min Temperature range 400°C max.
Five slots for manual ow
Correction function Maintains column ow rate during column oven heating Dynamic range N: 10 3
controllers are in the clear case Workstations For Capillary Split/Splitless, Direct P: 10 3
atop the main unit. (Split/splitless injection mode) Minimum detected quantity N: 0.4pgN/s (azobenzene)
LabSolutions LC/GC Ver.5
Five AFC/APC slots are in the Pressure setting range 0 ~ 970kPa P: 0.05pgP/s (malathion)
• LabSolutions LC/GC Ver.5 is the next generation of chromatography data system that integrates control of GC* (GC-2010 Plus, GC-2010, GC-2014, GC-2025
back bottom of the main unit. and GC-14B) and LC and deliver greater network capability. Programmable steps 7 (pressure-decreasing program possible)
* LabSolutions does not support Distillation GC Software and PONAsolution, please use GCsolution for these software. Programmed rate setting range -400 ~ 400kPa/min Display
Gases are supplied or cut off in
Manual Note: CBM-102 is necessary for controlling GC-14B. Split ratio setting range 0 ~ 9999.9 240 × 320 dot graphics display (30 characters × 16 lines)
conjunction with switching controllers Manual ow GCsolution Ver.2 Total ow rate setting range 0 ~ 1200mL/min
controllers
ON/OFF power to the main unit • GCsolution Ver.2 supports not only GC-2014, but also GC-2025*, GC-2010 Plus*, GC-2010, GC-17A, GC-1700 and GC-14A/B. Correction function Maintains column average linear velocity during column oven heating Dimensions, Weight, Power Requirements (GC main unit)
* GC-2010 Plus can be controlled by GCsolution Ver.2.32 or later and GC-2025 by GCsolution Ver. 2.40 or later respectively. (for capillary only)
or detector even if the low-cost Note1: CBM-102 is necessary for controlling GC-17A, GC-1700 and GC-14A/B and the data acquisition. CBM-102 is not sold in EU area. (Pressure mode direct injection) Dimensions 400 (W) × 690 (H) × 607 (D) mm
manual controllers are used. Note2: In controlling GC-14A, the workstation functionalities are partly limited like the detector range 4 cannot be used. Pressure setting range 0 ~ 970kPa/min Weight 48kg (GC-2014AF model)
All parameters for GC analysis • Both LabSolutions and GCsolution software can control a maximum of four GC units in a computer. By inputting detector analog signal into CBM-102, data Programmable steps 7 Power Requirements AC100V/120V 230V
acquisition is possible even on other Shimadzu GC models that cannot be controlled by the software. 1800VA (GC-2014AF model, AC100V/120V) or
are controlled digitally when Programmed rate setting range -400 ~ 400kPa/min 2600VA (GC-2014AF model, AC230V), 50/60Hz
Correction function Maintains column average linear velocity during column oven heating
APC’s are used to control Solenoid valve unit Chromatopac C-R8A * (for capillary only)
detector gases. This facilitates Electronic (Flow-rate mode direct injection)
controllers • Acknowledged data processing functions and ease of operation
the setting of analytical • Built-in validation functions Flow rate setting range 0 ~ 1200mL/min
conditions and log management • High-speed RS-232C port provided standard Programmable steps 7 -400 ~ 400mL/min
Programmed rate setting range
by a data station. • Easy operation designed for factory use For Single Packed, Direct (AMC)
* Chromatopac C-R8A is not sold in EU area.
• C-R8A uses a SD card as the memory device. Flow rate setting range 0~100mL/min
Correction function Maintenance column ow rate during column oven heating
AFC
GC-2014
11 12 Capillary and Packed Gas Chromatograph 13