Page 26 - Shimadzu EDX-8100
P. 26

Options








            Vacuum Measurement UnitɹP/N 212-25425-42           EDX-FTIR Contaminant Finder/Material Inspector                         Polyester Filmɹ                                    Briquet Press MP-35
            Use this unit for sensitive measurements of light elements. It requires   EDXIR-Analysis software                         P/N 202-86501-56 (500 sheets/set)                   Operation      Automatic
            space for installation of a rotary pump and switch box at the side or   P/N 206-33175-92/93                               Sample-holding film (for heavy element analysis)    Press          Hydraulic
            rear of the desk supporting the main unit.         By measuring the sample with both EDX and FTIR systems and                                                                 Maximum Pressure  350 kN
                                                               using EDXIR-Analysis to analyze both EDX and FTIR data, elements       Polypropylene Film                                  Pressure Setting  Arbitrary with a valve
            Helium Replacement Measurement Unit                can be identified automatically with high accuracy.                                                                        Method         Place the sample in a cup or the ring and press it.
                                                                                                                                      P/N 219-82019-05 (73 mm W × 92 m roll)              Press head     Plane type
            P/N 212-25440-41                                                                                                          Sample-holding film (for light element analysis)    Power          3-phase, 200 V±10 %, 50/60 Hz, 3 A
            This unit is used for highly sensitive measurements of light elements   Sample Cells                                                                                          Dimension      W 500 × D 500 × H 1210 mm
            in liquid samples. Does not include a helium cylinder or regulator.                                                       Spotting Filter Paper                               Weight         240 kg
                                                               3571 General Open-End X-Cell (no lid)
                                                                                                                                      P/N 210-16043-50   ø30 mm   50 sheets/set
            Turret Unit  P/N 212-25389-41                      P/N 219-85000-55 (100 cells/set)                                       P/N 210-16043-51   ø20 mm   50 sheets/set
            Turret for 12 samples. It permits                   (Outer diameter: 31.6 mm, volume: 10 mL)                              Drop a liquid sample on the filter paper, dry, and analyze.
            continuous measurements of                         Polyethylene sample cell for liquid and powder
            samples up to 32 mm in diameter. It                samples.                                                               Filter Paper Holder
            improves throughput, especially for                3529 General X-Cell (with lid)
            measurements in a vacuum or                                                                                               P/N 205-07221
            helium atmosphere.                                 P/N 219-85000-52 (100 cells/set)
                                                                (Outer diameter: 32 mm, volume: 8 mL)
            Small Spot Analysis Kit                            For liquid samples. Equipped with a relief hole
                                                               and liquid retainer in case of liquid expansion.
            P/N 212-25880-41
            This kit is especially useful for analyzing trace foreign matter and  3577 Micro X-Cell                                                                                                                            Flat press heads
            micro areas.                                       P/N 219-85000-54 (100 cells/set)                                       Sample Holder/Stocker for Contaminant Measurement
            This combination includes a 0.3 mm diameter collimator and   (Outer diameter: 31.6 mm, volume: 0.5 mL)                    EDXIR-Holder
            high-resolution camera.                            For trace samples. Recommended for use with a                          P/N 212-25890-41 (25 sheets)
                                                               collimator.                                                                                              Polypropylene Film Designed
            Screening Analysis Kits                                                                                                                                     for Fluorescence X-ray  Adhesive Layer
                                                               3561 Universal X-Cell
            P/N 212-25475-41
                                                               P/N 219-85000-53 (100 cells/set)
            RoHS/ELV Screening Analysis Kit
                                                                (Outer diameter: 31.6 mm, volume: 8 mL)
            With check samples for five elements
                                                               For liquid and thin-film samples. Equipped with a
            P/N 212-25476-41                                   relief hole and liquid retainer in case of liquid
            RoHS and Halogen Screening Analysis Kit            expansion. Equipped with a ring to tightly hold
                                                                                                                                              How to Use with EDX                           Attach the Samples     How to Use with FTIR
            With check samples for six elements                thin-film samples with film.
                                                                                                                                      Close the holder and place the polypropylene  lm   When the Holder is Open  Open the holder and press the samples attached to
            P/N 212-25477-41                                   X-ray Tube (Premium type)                                              to the irradiation side (downside).         (Inside of the Holder)   the adhesive layer against the prism.
            RoHS, Halogen, and Antimony Screening Analysis Kit
                                                               P/N 212-24541-41
            With check samples for seven elements                                                                                     Briquetting Ring
                                                               Premium models with more durable X-ray tube windows. The
                                                               warranty period is 2 years. (Standard type is 1 year).                 The vinyl chloride resin rings are used for silicate samples, while the aluminum
                                                                                                                                      rings are used for other types of samples, such as cement.
             Sample Holder Ring Removal Kit                                                                                            Materials  Aluminum Rings
                                                                                                                                              P/N 202-82397-53   ID ø35 mm    OD ø35 mm   Analysis dia. ø30 mm    500pcs/set
             This kit is for removing the ring that holds the film attached to the sample container.                                          Vinyl chloride
             The ring can be removed by inserting the assembled sample container into the kit body and pushing the push bar from the top.     Recommendation
                                                                                                                                              P/N 212-21654-05   ID ø22 mm   OD ø26 mm    Analysis dia. ø20 mm    100pcs/set
                                                                                                                                              Others
                                                                                                                                              P/N 212-21654-01   ID ø35 mm    OD ø42 mm    Analysis dia. ø30 mm    100pcs/set
                                                                                                                                              P/N 212-21654-02   ID ø35 mm    OD ø42 mm    Analysis dia. ø30 mm    500pcs/set
                                                                                                                                              P/N 212-21654-11   ID ø25 mm    OD ø32 mm    Analysis dia. ø20 mm    100pcs/set
                                                                                                                                              P/N 212-21654-12   ID ø25 mm    OD ø32 mm    Analysis dia. ø20 mm    500pcs/set
                                                                                                                                              P/N 212-21654-09   ID ø14 mm    OD ø18 mm    Analysis dia. ø10 mm    100pcs/set
                                                                                                                                              P/N 212-21654-10   ID ø14 mm    OD ø18 mm    Analysis dia. ø10 mm    500pcs/set



        26                                                                                                                                                                                                                                  27
   21   22   23   24   25   26   27   28