Page 27 - Shimadzu EDX-8100
P. 27

Options








 Vacuum Measurement UnitɹP/N 212-25425-42  EDX-FTIR Contaminant Finder/Material Inspector  Polyester Filmɹ  Briquet Press MP-35
 Use this unit for sensitive measurements of light elements. It requires   EDXIR-Analysis software  P/N 202-86501-56 (500 sheets/set)  Operation  Automatic
 space for installation of a rotary pump and switch box at the side or   P/N 206-33175-92/93  Sample-holding film (for heavy element analysis)  Press  Hydraulic
 rear of the desk supporting the main unit.   By measuring the sample with both EDX and FTIR systems and   Maximum Pressure  350 kN
 using EDXIR-Analysis to analyze both EDX and FTIR data, elements   Polypropylene Film   Pressure Setting  Arbitrary with a valve
 Helium Replacement Measurement Unit  can be identified automatically with high accuracy.  Method  Place the sample in a cup or the ring and press it.
            P/N 219-82019-05 (73 mm W × 92 m roll)              Press head     Plane type
 P/N 212-25440-41  Sample-holding film (for light element analysis)  Power     3-phase, 200 V±10 %, 50/60 Hz, 3 A
 This unit is used for highly sensitive measurements of light elements   Sample Cells  Dimension  W 500 × D 500 × H 1210 mm
 in liquid samples. Does not include a helium cylinder or regulator.  Spotting Filter Paper   Weight  240 kg
 3571 General Open-End X-Cell (no lid)
            P/N 210-16043-50   ø30 mm   50 sheets/set
 Turret Unit  P/N 212-25389-41  P/N 219-85000-55 (100 cells/set)  P/N 210-16043-51   ø20 mm   50 sheets/set
 Turret for 12 samples. It permits    (Outer diameter: 31.6 mm, volume: 10 mL)  Drop a liquid sample on the filter paper, dry, and analyze.
 continuous measurements of   Polyethylene sample cell for liquid and powder
 samples up to 32 mm in diameter. It   samples.   Filter Paper Holder
 improves throughput, especially for   3529 General X-Cell (with lid)
 measurements in a vacuum or   P/N 205-07221
 helium atmosphere.  P/N 219-85000-52 (100 cells/set)
  (Outer diameter: 32 mm, volume: 8 mL)
 Small Spot Analysis Kit  For liquid samples. Equipped with a relief hole
 and liquid retainer in case of liquid expansion.
 P/N 212-25880-41
 This kit is especially useful for analyzing trace foreign matter and  3577 Micro X-Cell             Flat press heads
 micro areas.  P/N 219-85000-54 (100 cells/set)  Sample Holder/Stocker for Contaminant Measurement
 This combination includes a 0.3 mm diameter collimator and   (Outer diameter: 31.6 mm, volume: 0.5 mL)  EDXIR-Holder
 high-resolution camera.  For trace samples. Recommended for use with a  P/N 212-25890-41 (25 sheets)
 collimator.                                   Polypropylene Film Designed
 Screening Analysis Kits                       for Fluorescence X-ray  Adhesive Layer
 3561 Universal X-Cell
 P/N 212-25475-41
 P/N 219-85000-53 (100 cells/set)
 RoHS/ELV Screening Analysis Kit
  (Outer diameter: 31.6 mm, volume: 8 mL)
 With check samples for five elements
 For liquid and thin-film samples. Equipped with a
 P/N 212-25476-41  relief hole and liquid retainer in case of liquid
 RoHS and Halogen Screening Analysis Kit  expansion. Equipped with a ring to tightly hold
                    How to Use with EDX                           Attach the Samples     How to Use with FTIR
 With check samples for six elements  thin-film samples with film.
            Close the holder and place the polypropylene  lm   When the Holder is Open  Open the holder and press the samples attached to
 P/N 212-25477-41  X-ray Tube (Premium type)  to the irradiation side (downside).  (Inside of the Holder)  the adhesive layer against the prism.
 RoHS, Halogen, and Antimony Screening Analysis Kit
 P/N 212-24541-41
 With check samples for seven elements  Briquetting Ring
 Premium models with more durable X-ray tube windows. The
 warranty period is 2 years. (Standard type is 1 year).  The vinyl chloride resin rings are used for silicate samples, while the aluminum
            rings are used for other types of samples, such as cement.
 Sample Holder Ring Removal Kit  Materials  Aluminum Rings
                    P/N 202-82397-53   ID ø35 mm    OD ø35 mm   Analysis dia. ø30 mm    500pcs/set
 This kit is for removing the ring that holds the film attached to the sample container.  Vinyl chloride
 The ring can be removed by inserting the assembled sample container into the kit body and pushing the push bar from the top.  Recommendation
                    P/N 212-21654-05   ID ø22 mm   OD ø26 mm    Analysis dia. ø20 mm    100pcs/set
                    Others
                    P/N 212-21654-01   ID ø35 mm    OD ø42 mm    Analysis dia. ø30 mm    100pcs/set
                    P/N 212-21654-02   ID ø35 mm    OD ø42 mm    Analysis dia. ø30 mm    500pcs/set
                    P/N 212-21654-11   ID ø25 mm    OD ø32 mm    Analysis dia. ø20 mm    100pcs/set
                    P/N 212-21654-12   ID ø25 mm    OD ø32 mm    Analysis dia. ø20 mm    500pcs/set
                    P/N 212-21654-09   ID ø14 mm    OD ø18 mm    Analysis dia. ø10 mm    100pcs/set
                    P/N 212-21654-10   ID ø14 mm    OD ø18 mm    Analysis dia. ø10 mm    500pcs/set



 26                                                                                                               27