6200
Rotor has prescribed operating life cycle and years of operation, after that the rotor must be replaced.
For more details, please contact us.
※ The number of times allowed for autoclaving is limited. For more details, please contact us.
Tube
Flow cytometry
tube-20
tube-6-1 tube-6-2 tube-6-3
tube-21
tube-8-1
tube-7-2
tube-8-2
28 x 5〜10mL blood collection 48 x 5〜10mL blood collection 48 x 5〜10mL blood collection
68 x 10mL blood collection
36 x 72 x 80 x 68 x 5〜7mL 24 x 8mL CPT cell 80 x 10mL 10ml tube-8-3 15ml 5ml 5ml 5ml tube-7-1 7ml tube-20 16 x 15mL 28 x 15mL tube-10 28 x 15mL 32 x 15mL 4 x 50 mL 8 x 50 mL 12 x 50 mL
tube-7-3 tube-8-1 tube-8-2 tube-8-3 15ml
50ml
10ml
7ml
10ml
Nominal Capacity 10ml 7ml 10ml 15ml
10ml
1.5/2mL 1.5/2mL 1.5/2mL thin blood collection tube preparation tube (glass) tube/15mL (glass) tube/15mL (glass) tube/15mL (glass) tube/15mL (glass) conical tube conical tube conical tube conical tube (glass) (glass) (glass)
Tube size (mm) diam. x length 9.5〜11×36〜42 12〜13.7×62〜110 13.5〜15.8×81〜130 12〜13.8×65〜95 15〜17.2×52〜110 12〜17.2×72〜110 12〜16.8×72〜110 17×121 27〜36.4×85〜110
Maximum Speed rpm 4,800 4,000 3,500 3,500 3,500 3,500 3,500 4,800 4,000 3,500 4,800 3,500 4,000 3,500 4,800 3,500 4,000
Maximum RCF x 4,250 3,040 2,290 2,300 2,310 2,080 2,300 4,150 2,970 2,300 4,280 2,300 3,060 2,330 4,150 2,330 2,990
Tube Rack, Adaptor Code No. 055-4800 Bucket Code No. Adaptor Code No. 055-6900 055-4740 Bucket Code No. 055-0880 Bucket Code No. 055-4780 055-4760
053-5840 055-0260 053-5840 053-5840
— — *9 — — *3 — *9 — — —
055-0880P BT-11
BT-02 BT-02 055-4780P 055-4760
053-5840 053-5840
Tube Rack, Adaptor Code No. 055-1190 055-1140 055-1160 055-1150
— — — — — — *3 — — — — — — —
055-1150
Tube Rack, Adaptor Code No. 055-0770 055-0730 055-0750 055-0740
— — — — — — — *3 — — — — — —
055-0730 055-0750 055-0740
*1 5-7mL blood collection tubes which can be used are insepack Ⅱ and ST series by SEKISUI,
Venoject Ⅱ by TERUMO, Neo tube by NIPRO and Vacutainer by BD.
This convenient tube rack can accommodate various sizes (such as 5 mL,
7 mL, 10 mL) blood collection tubes, as well as 15 mL glass tubes. The tubes for flow cytometry are applicable.
*2 The blood collection tubes which can be used are Vacutainer 8mL CPT by BD.
*3 5-10mL blood collection tubes which can be used are insepack Ⅱ and ST series by SEKISUI,
Venoject Ⅱ by TERUMO, Neo tube by NIPRO and Vacutainer by BD.
The tubes for flow cytometry are applicable.
Tube
tube-12 tube-14 BT62-1 BT62-2 tube-25-2
500mL tube
4 x 50 mL 12 x 50 mL 16 x 50 mL 4 x 100mL 4 x 175/225mL 175ml tube-13 4 x 250mL 4 x 250mL 4 x 250mL 4 x 500mL 4 x Self-standing Self-standing for sputum tube-25-3 Self-standing for sputum
4 x 175/200/225mL
250ml
tube-25-1
250ml
225ml
Nominal Capacity 200ml
conical tube conical tube conical tube (glass) conical tube conical tube *7 *7 *7 *8 for sputum ×4 ×8 ×12 ×8 ×12 ×16
38〜46.5×
Tube size (mm) diam. x length 30×117 38〜46.5×113〜120 61×118/61×137 61×118/61×130/61×137 60〜62×100〜134.4 85×135 cap sizeφ48 cap sizeφ48 cap sizeφ37 cap sizeφ31 cap sizeφ48 cap sizeφ37 cap sizeφ31
83〜120
Maximum Speed rpm 4,800 4,000 3,500 3,500 4,800 4,000 4,800 3,500 4,000 3,500 4,800 4,000 4,000 4,800 4,000 3,500
Maximum RCF x 4,250 3,040 2,330 2,330 4,250 2,970 4,250 2,330 3,080 2,380 4,300 3,080 3,080 4,250 3,020 2,250 2,290 2,300
Tube Rack, Adaptor Code No. 055-6070 055-4770 055-4850 055-4850 055-0430 055-0440 055-0450
— — — — — *4 — — — — — —
*5
BT-12+
BT-14 BT-14 BT-11+ 055-0440 BT-12+
055-4850 055-4850 055-0430 055-0450
Tube Rack, Adaptor Code No. 055-1170 055-1200 055-1210
can be used
— — — — *4,6 — — — — — — —
without adaptors
@O
Tube Rack, Adaptor Code No. 055-0760 055-1180 055-0780 055-0780 055-0810 055-0800 055-0790
*4 can be used
— — — — — — *5 — — — —
*6 without adaptors
055-0780 055-0780 055-0810 055-0800 055-0790
*4 175/225mL Falcon conical tubes (catalogue No.352076/352075) require cushions (catalogue No.352090).
*5 200mL Nalgene conical tubes (catalogue No.376813) require cushions (catalogue No.377585).
Maximum RCF is 3,020 xg when SF-5004 rotor is used.
*6 Sealing caps can not be used with 200/225mL conical tubes.
*7 Nalgene, Helolab, and Corning 250mL flat bottom bottles can be used.
*8 500mL bottles (Code No.K15501C/PPCO) can be used.
*9 The bucket cannot be used for a glass spitz tube (tapered tube).