6200
                                        Rotor has prescribed operating life cycle and years of operation, after that the rotor must be replaced.
                                        For more details, please contact us.
                                     ※ The number of times allowed for autoclaving is limited. For more details, please contact us.


 Tube

                                     Flow cytometry
         tube-20
             tube-6-1 tube-6-2 tube-6-3
                                                                                               tube-21
  tube-8-1
                     tube-7-2
    tube-8-2
             28 x 5〜10mL blood collection 48 x 5〜10mL blood collection 48 x 5〜10mL blood collection
   68 x 10mL blood collection
 36 x   72 x   80 x   68 x 5〜7mL  24 x 8mL CPT cell  80 x 10mL  10ml     tube-8-3 15ml  5ml    5ml    5ml    tube-7-1  7ml     tube-20  16 x 15mL  28 x 15mL  tube-10  28 x 15mL  32 x 15mL  4 x 50 mL  8 x 50 mL  12 x 50 mL
                        tube-7-3 tube-8-1 tube-8-2 tube-8-3 15ml
                                                                                               50ml
                          10ml
                     7ml
                               10ml
 Nominal Capacity  10ml     7ml     10ml                   15ml
      10ml
 1.5/2mL  1.5/2mL  1.5/2mL  thin blood collection tube  preparation tube  (glass)  tube/15mL (glass)  tube/15mL (glass)  tube/15mL (glass)  tube/15mL (glass)  conical tube  conical tube  conical tube  conical tube  (glass)  (glass)  (glass)
 Tube size (mm)  diam. x length  9.5〜11×36〜42  12〜13.7×62〜110  13.5〜15.8×81〜130  12〜13.8×65〜95  15〜17.2×52〜110  12〜17.2×72〜110  12〜16.8×72〜110  17×121  27〜36.4×85〜110
 Maximum Speed  rpm  4,800  4,000  3,500  3,500  3,500  3,500  3,500  4,800  4,000  3,500  4,800  3,500  4,000  3,500  4,800  3,500  4,000
 Maximum RCF  x   4,250  3,040  2,290  2,300  2,310  2,080  2,300  4,150  2,970  2,300  4,280  2,300  3,060  2,330  4,150  2,330  2,990
 Tube Rack, Adaptor Code No.  055-4800  Bucket Code No. Adaptor Code No.  055-6900  055-4740  Bucket Code No.  055-0880  Bucket Code No.  055-4780  055-4760
 053-5840  055-0260  053-5840                         053-5840
 —  —     *9    —         —             *3    —             *9    —                   —                   —
                                    055-0880P                                                   BT-11
      BT-02                                             BT-02              055-4780P            055-4760
      053-5840                                          053-5840
 Tube Rack, Adaptor Code No.  055-1190  055-1140  055-1160                          055-1150
 —  —  —  —  —  —   *3    —         —                   —         —         —                   —         —
                                                                                      055-1150
 Tube Rack, Adaptor Code No.  055-0770  055-0730                055-0750                                055-0740
 —  —  —  —  —  —  —          *3    —         —         —                   —         —         —
                          055-0730                                055-0750                               055-0740

                                                  *1  5-7mL blood collection tubes which can be used are insepack Ⅱ and ST series by SEKISUI,
                                                    Venoject Ⅱ by TERUMO, Neo tube by NIPRO and Vacutainer by BD.
   This convenient tube rack can accommodate various sizes (such as 5 mL,
   7 mL, 10 mL) blood collection tubes, as well as 15 mL glass tubes.  The tubes for flow cytometry are applicable.
                                                  *2  The blood collection tubes which can be used are Vacutainer 8mL CPT by BD.
                                                  *3  5-10mL blood collection tubes which can be used are insepack Ⅱ and ST series by SEKISUI,
                                                    Venoject Ⅱ by TERUMO, Neo tube by NIPRO and Vacutainer by BD.
                                                    The tubes for flow cytometry are applicable.

 Tube


     tube-12    tube-14         BT62-1  BT62-2                                        tube-25-2
                                                      500mL tube
 4 x 50 mL  12 x 50 mL  16 x 50 mL  4 x 100mL  4 x 175/225mL  175ml       tube-13  4 x 250mL  4 x 250mL  4 x 250mL  4 x 500mL  4 x Self-standing   Self-standing for sputum  tube-25-3 Self-standing for sputum
      4 x 175/200/225mL
                                           250ml
                                                                               tube-25-1
                                    250ml
               225ml
 Nominal Capacity  200ml
 conical tube conical tube conical tube  (glass)  conical tube  conical tube  *7  *7  *7  *8  for sputum  ×4  ×8  ×12  ×8  ×12  ×16
 38〜46.5×
 Tube size (mm)  diam. x length  30×117  38〜46.5×113〜120  61×118/61×137  61×118/61×130/61×137  60〜62×100〜134.4  85×135  cap sizeφ48  cap sizeφ48 cap sizeφ37 cap sizeφ31 cap sizeφ48 cap sizeφ37 cap sizeφ31
 83〜120
 Maximum Speed  rpm  4,800  4,000  3,500  3,500  4,800  4,000  4,800  3,500  4,000  3,500  4,800  4,000  4,000  4,800  4,000  3,500
 Maximum RCF  x   4,250  3,040  2,330  2,330  4,250  2,970  4,250  2,330  3,080  2,380  4,300  3,080  3,080  4,250  3,020  2,250  2,290  2,300
 Tube Rack, Adaptor Code No.  055-6070  055-4770  055-4850  055-4850                         055-0430  055-0440  055-0450
 —  —  —  —  —  *4  —               —         —         —         —              —
          *5
                                                                                                     BT-12+
      BT-14                BT-14                                                              BT-11+  055-0440  BT-12+
      055-4850            055-4850                                                            055-0430     055-0450
 Tube Rack, Adaptor Code No.  055-1170  055-1200                055-1210
                                  can be used
 —  —  —  —  *4,6  —  —   —                   —         —                        —                   —
                                without adaptors
                                                                         @O
 Tube Rack, Adaptor Code No.  055-0760  055-1180  055-0780  055-0780     055-0810  055-0800  055-0790

                    *4                                can be used
 —  —  —  —  —  —   *5    —         —                             —                                  —
                    *6                              without adaptors
                055-0780                      055-0780                    055-0810  055-0800  055-0790

             *4  175/225mL Falcon conical tubes (catalogue No.352076/352075) require cushions (catalogue No.352090).
             *5  200mL Nalgene conical tubes (catalogue No.376813) require cushions (catalogue No.377585).
                Maximum RCF is 3,020 xg when SF-5004 rotor is used.
             *6  Sealing caps can not be used with 200/225mL conical tubes.
             *7  Nalgene, Helolab, and Corning 250mL flat bottom bottles can be used.
             *8  500mL bottles (Code No.K15501C/PPCO) can be used.
             *9  The bucket cannot be used for a glass spitz tube (tapered tube).
   2   3   4   5   6   7   8