Page 5 - Kubota - 6200
P. 5
6200
Plate Rotor
PF-206
Maximum Speed Maximum RCF Adaptor
Plate Nominal Capacity Plate size mm rpm xg Code No.
2 x PCR plate *1
6 x MTP 86(W)×128(D)×52(H) 4,000 1,790 —
2 x DWP
tube-15 tube-16
* Autoclavable
PF-745S
*1
2 x PCR plate
12 x MTP 86(W)×128(D)×90(H) 4,200 3,100 Trays
4 x DWP 055-6380
*2
tube-15 tube-16
Tray Code No.055-6380(optional)
Ethanol precipitation can be
carried out at 3,100 xg
Shield covers that can be used
for biohazard proof are
equipped with rotor.
Double stack Deep-well plates
can be used. 12 x 96 well plate 4 x deep-well plate 4 x square-well 2 deep-well + filter 2 x PCR plate
plate plate
Swinging Bucket Rotor
Tube
Flow cytometry
tube tube-4
1.5mlTube
2mlTube tube-6-1 tube-6-2 tube-6-3 tube-20 tube-7-3 tube-7-1 tube-8-1 tube-20
5ml tube-7-1
8 x 7〜10mL blood collection
tube-8-2
tube-7-2
tube-7-2
tube-7-3 tube-8-1 tube-8-2 tube-8-3
tube-8-3
5ml 5ml 16 x 5〜10mL blood collection 4 x 7〜10mL blood collection 4 x 7〜10mL blood collection 10ml 15ml
10ml 15ml
10ml
7ml
Nominal Capacity 24 x 1.5/2mL *3 7ml 7ml 10ml *4 7ml 7ml 7ml 10ml 10ml
tube/15mL tube/15mL glass *5 tube/15mL glass *5 tube/15mL glass *5
Tube size (mm)
diam. x length 9.5〜11 x 36〜42 12〜17 x 65〜105 12〜17.2 x 86〜110 12〜17.8 x 87〜110 12〜17.2 x 86〜110
Maximum Speed rpm 4,000 4,000 4,000 4,000 4,000
Maximum RCF xg 2,410 2,410 2,540 2,500 2,520
Bucket 053-4800 053-4930 053-4910 053-4990 053-4900
Code No.
BT-67
BT-69
BT-68
BT-65 053-4910 053-4990 053-4900
Autoclavable * Adaptor 053-4800
Code No. 055-7400
SF-240 *6
Max 4,000 rpm — — — —
Max 2,610 xg BT-36
055-7400
024-1400 (Rubber cushion)
BT-37
024-1400
Tube
tube-21
4 x 15mL 4 x 15mL tube-10 4 x 15mL 8 x 15mL 4 x 50mL 4 x 50mL tube-11 4 x 50mL
50ml
Nominal Capacity 15ml 50ml
Conical tube Conical tube Conical tube Conical tube glass Conical tube Conical tube
Tube size (mm)
diam. x length 17 x 121 17 x 121 17 x 121 17 x 121 27〜37 x 95〜110 30 x 117 30 x 117
Maximum Speed rpm 4,000 4,000 4,000 4,000 4,000 4,000 4,000
Maximum RCF xg 2,580 2,590 2,590 2,580 2,540 2,610 2,610
Bucket 053-4910 053-5010 053-0040 053-4900 053-4990 053-0040 053-5010
Code No.
*7 *7
BT-68 OFX BT-67 BT-69 OFX
053-4910 053-4900 053-4990
Autoclavable * Adaptor 055-1280 055-1280
Code No.
SF-240
Max 4,000 rpm — — — — —
Max 2,610 xg
BT-38 BT-38
055-1280 055-1280
Rotor has prescribed operating life cycle and years of operation, after that the rotor must be replaced.
For more details, please contact us.
* The number of times allowed for autoclaving is limited. For more details, please contact us.
*1 Verify plates' strength before centrifugation. Plates in lower position may fracture.
*2 Optional tray (code no.055-6380) is available.
*3 Buckets can be made by request. Please contact us.
*4 5-10mL blood collection tubes which can be used are InsepackⅡ by SEKISUI, Venoject Ⅱ by TERUMO, Neo tube by NIPRO and Vacutainer by BD.
*5 7-10mL blood collection tubes which can be used are InsepackⅡ by SEKISUI, Venoject Ⅱ by TERUMO, Neo tube by NIPRO and Vacutainer by BD.
*6 In case of using glass tubes, rubber cushion (code no.024-1400) is necessary.
*7 Sealing caps and o-rings (sillicon) are equipped with buckets. Autoclavable at 121℃.