Page 34 - Shimadu Consumables Catalog
P. 34

UHPLC/HPLC Columns



           Shim-pack XR Series


              Shim-pack XR Series, Shim-pack XR-ODS II and XR-ODS III High-Pressure Columns
             for Higher Resolution and Sensitivity
              While the Shim-pack XR-ODS II and XR-ODS III use the
                                                                             Shim-pack XR-ODS II  Shim-pack XR-ODS III
             same 2.2 μm packing particle size as the Shim-pack
                                                          Length (mm)         30, 50, 75, 100, 150  50, 75  150, 200
             XR Series columns, they have higher 60 and 100MPa
                                                          Particle Size (μm)       2.2          1.6      2.2
             pressure tolerance. This allows them to achieve high-
                                                          Pore Size (nm)            8           7.5      8
             resolution fast analysis in a long column using a water/
                                                          Surface Area (m2/g)      470         500       470
             methanol mobile phase. This column significantly
                                                          Carbon Loading           20%         22%      20%
             extends the range of applications of high-resolution
                                                          Pressure Tolerance (MPa)  60         100       100
             fast analysis to include analysis near room temperature.
                                                          Pore Volume (mL/g)        1          0.95      1
             The Shim-pack XR-ODSII and XR-ODS III columns are
                                                          End-capping              Yes          Yes      Yes
             ideal for the Nexera UHPLC or Prominence UFLC. This
                                                          Bonding Type          Monomeric    Monomeric  Monomeric
             combination achieves both faster speed and higher
                                                          pH Range                2 - 7.5      2 - 7.5  2 - 7.5
             resolution.
                                                          USP Code                 L1           L1       L1
           Extensive product range, including 1.5 mmI.D. column to reduce mobile phase consumption
           The Shim-pack XR-ODS II range includes a 1.5 mmI.D. model in addition to normal 2 mm and 3 mmI.D. columns. With an optimal
           flow rate of 0.2 to 0.3 mL/min, the 1.5 mmI.D. column offers the optimal flow rate for LC/MS and reduces mobile phase
           consumption.
           Select a column to suit your purpose, whether shorter analysis times or high resolution

           The Shim-pack XR-ODS III lineup features two columns: a short one utilizing a packing material with a particle size of 1.6 μm and a
           long one utilizing a 2.2 μm particle size, which is equivalent to the conventional XR column. This extensive lineup allows users to
           select a column according to analysis objectives, whether it’s a short size to further shorten analysis times, or a long size to
           achieve high resolution while retaining the ease of use of the conventional XR column.


                                      Shim-pack VP-ODS (150 mmL. × 4.6 mmI.D., 5 µm, P/N: 228-34937-91)
                        Peaks                                                          Conditions
                      1. Acetophenone                                                Mobile Phase  :  55 % Aqueous
                      2. Propiophenone                                                            Acetonitrile Solution
                      3. Butyrophenone                                               Flow Rate   :  1.0 mL/min
                      4. Valerophenone                                               Col. Temp.   :  40 °C
                      5. Hexanophenone                                               Injection Vol.  :  5 µL








            Shim-pack XR-ODS III (50 mmL. × 2 mmI.D., 1.6 μm, P/N: 228-59922-91)  Shim-pack XR-ODS III (200 mmL. × 2 mmI.D., 2.2 μm, P/N: 228-59910-92)












            Conditions                                          Conditions
           Mobile Phase  :  55 % Aqueous Acetonitrile Solution  Mobile Phase  :  55 % Aqueous Acetonitrile Solution
           Flow Rate   :  1.1 mL/min                          Flow Rate   :  0.6 mL/min
           Col. Temp.   :  40 °C                              Col. Temp.   :  50 °C
           Injection Vol.  :  5 µL                            Injection Vol.  :  5 µL





         Pg A-30
   29   30   31   32   33   34   35   36   37   38   39