GC Glass Insert



           Glass Insert for Capillary Column Analysis


           Glass insert is very important to prevent the column from being contaminated by sample components. Please choose an appropriate
           insert according to your system model, injection port and injection method, and exchange it regularly to avoid poor reproducibility
           and peak shape caused by the crossover of residual samples, etc.
                                                                                                  S: Standard; O: Option
                                                                            GC-2010         GC-17A    GC-
                                                                     Nexis
                                                                             Plus
                                                                                            ver. 1-3
                                             Specification          GC-2030  GC-2010  GC-2014  GC-1700   14A  GC-8A
                                                                                                     GC-
                                                                            GC-2025         GC-18A   14B
                         P/N
                                                                           SPL-2010
                                                                     SPL-
                                                                             Plus
                                            Injection Unit –›        2030  SPL-2010  SPL-2014  SPL-17  SPL-14 SPL-G9
                                                                           SPL-2025
                      221-41444                                       O       O       S       S
                               (ID 3.5mm; OD 5mm; Length 95mm)
                      221-41444-01  (ID 3.5mm; OD 5mm; Length 95mm)   O       S               O
                   For Split  221-37574-01  (99mm)                                                   S
                      221-25822-03                                                                         S
                               (87mm)
                      227-35007-01                                    S       O       O       O
                               (ID 3.4mm; OD 5mm; Length 95mm, Deactivated, with wool, 5pcs)
                      221-48335-01                                            S       S       O
                               (ID 3.5mm; OD 5mm; Length 95mm)
                      221-41544  (95mm)                                       O       O       S      S
                   For Splitless
                                                                                      O
                      221-75192
                                                                              O
                               (ID 3.4mm; OD 5mm; Length 95mm, Deactivated, 5pcs)
               Split/Splitless Injection Method  221-25944-03  (87mm)  O S    O       O       O            S
                      221-32544
                               (99mm)
                      227-35008-01
                               (ID 3.4mm; OD 5mm; Length 95mm, Deactivated, with wool* 2 , 5pcs)
                                                                                      O
                                                                              O
                      221-75187
                               (ID 3.4mm; OD 5mm; Length 95mm, Deactivated, with wool, 5pcs)
                                                                      O
                                                                                      O
                                                                              O
                      221-75188
                               (ID 3.4mm; OD 5mm; Length 95mm, Deactivated, needle onto wool, 5pcs)
                                                                      O
                                                                              O
                                                                                      O
                      221-75189
                               (ID 3.4mm; OD 5mm; Length 95mm, Deactivated, needle into wool, 5pcs)
             Injection Port Side  For Split and Splitless  221-75190  (ID 3.4mm; OD 5mm; Length 95mm, Deactivated, Straight Through, 5pcs)  O  O  O
                                                                                      O
                                                                      O
                                                                              O
                      221-75191
                               (ID 3.4mm; OD 5mm; Length 95mm, Deactivated, needle into wool, 5pcs)
                                                                              O
                                                                      O
                      221-75193
                               (ID 3.4mm; OD 5mm; Length 95mm, Deactivated, with wool, 5pcs)
                                                                      O
                                                                              O
                      221-75194
                               (ID 3.4mm; OD 5mm; Length 95mm, Deactivated, 5pcs)
                      221-41444-05
                                                                                      O
                      221-41544-05  (ID 3.4mm; OD 5mm; Length 95mm, Deactivated, 5pcs)  O
                               (ID 2.6mm; OD 5mm; Length 95mm, Deactivated, 5pcs)
                      221-75195                                                       O
                               (ID 3.4mm; OD 5mm; Length 95mm, Deactivated, with wool, 5pcs)
                                            Injection Unit –›        WBI-  WBI-2010   WBI-  WBI-17
                                                                             Plus
                                                                                     2014
                                                                     2030
                                                                           WBI-2010
                      221-41599                                       O       O       O       S
               Direct          (95mm)
                                                                              S
              Injection  221-48335-01  (ID 3.5mm; OD 5mm; Length 95mm)  S  (WBI-2010)  S      O
               Method
                (WBI)  221-75197  (ID 3.4mm; OD 5mm; Length 95mm, Deactivated, with wool* 2 , 5pcs)  O  O
                      221-41599-05  (ID 2.6mm; OD 5mm; Length 95mm, Deactivated, for 0.53mmID column,   O
                               5pcs)
                                                                            GC-2010         GC-17A   GC-
                                                                     Nexis
                                                                                            ver. 1-3
                                             Specification          GC-2030  Plus GC-  GC-2014  GC-1700   14A  GC-8A
                                                                                                     GC-
                                                                             2010
                         P/N                                                GC-2025         GC-18A   14B
                                                                     SPL-
                                            Injection Unit –›        2030   SPL-2010   SPL-2014  SPL-17  SPL-14  SPL-G9
                                                                             Plus
              For SPME  221-75196*                                    O       O       O
                               (ID 0.75mm; OD 5mm; Length 95mm, Deactivated, 5pcs )

              For HS 10  221-76863-73  (ID 1.2mm; OD 5mm, Length 95mm, Deactivated, 5pcs)  S  S  S
                WBC   221-38107 * 1                                                   S              S
               Attach-         (139mm)
                ment  221-39148                                                                            S
                               (86 mm)
           * 1   Required if the WBC Attachment is used for a packed column injection in GC-2014, Insert for GC-14 septum purge unit is P/N: 221-38151-04
           * 2   Wool is 25mm from the top of insert.
           *   Can be used for AOC-6000 SPME
         Pg C-68