Page 218 - Shimadu Consumables Catalog
P. 218
GC Glass Insert
Glass Insert for Capillary Column Analysis
Glass insert is very important to prevent the column from being contaminated by sample components. Please choose an appropriate
insert according to your system model, injection port and injection method, and exchange it regularly to avoid poor reproducibility
and peak shape caused by the crossover of residual samples, etc.
S: Standard; O: Option
GC-2010 GC-17A GC-
Nexis
Plus
ver. 1-3
Specification GC-2030 GC-2010 GC-2014 GC-1700 14A GC-8A
GC-
GC-2025 GC-18A 14B
P/N
SPL-2010
SPL-
Plus
Injection Unit –› 2030 SPL-2010 SPL-2014 SPL-17 SPL-14 SPL-G9
SPL-2025
221-41444 O O S S
(ID 3.5mm; OD 5mm; Length 95mm)
221-41444-01 (ID 3.5mm; OD 5mm; Length 95mm) O S O
For Split 221-37574-01 (99mm) S
221-25822-03 S
(87mm)
227-35007-01 S O O O
(ID 3.4mm; OD 5mm; Length 95mm, Deactivated, with wool, 5pcs)
221-48335-01 S S O
(ID 3.5mm; OD 5mm; Length 95mm)
221-41544 (95mm) O O S S
For Splitless
O
221-75192
O
(ID 3.4mm; OD 5mm; Length 95mm, Deactivated, 5pcs)
Split/Splitless Injection Method 221-25944-03 (87mm) O S O O O S
221-32544
(99mm)
227-35008-01
(ID 3.4mm; OD 5mm; Length 95mm, Deactivated, with wool* 2 , 5pcs)
O
O
221-75187
(ID 3.4mm; OD 5mm; Length 95mm, Deactivated, with wool, 5pcs)
O
O
O
221-75188
(ID 3.4mm; OD 5mm; Length 95mm, Deactivated, needle onto wool, 5pcs)
O
O
O
221-75189
(ID 3.4mm; OD 5mm; Length 95mm, Deactivated, needle into wool, 5pcs)
Injection Port Side For Split and Splitless 221-75190 (ID 3.4mm; OD 5mm; Length 95mm, Deactivated, Straight Through, 5pcs) O O O
O
O
O
221-75191
(ID 3.4mm; OD 5mm; Length 95mm, Deactivated, needle into wool, 5pcs)
O
O
221-75193
(ID 3.4mm; OD 5mm; Length 95mm, Deactivated, with wool, 5pcs)
O
O
221-75194
(ID 3.4mm; OD 5mm; Length 95mm, Deactivated, 5pcs)
221-41444-05
O
221-41544-05 (ID 3.4mm; OD 5mm; Length 95mm, Deactivated, 5pcs) O
(ID 2.6mm; OD 5mm; Length 95mm, Deactivated, 5pcs)
221-75195 O
(ID 3.4mm; OD 5mm; Length 95mm, Deactivated, with wool, 5pcs)
Injection Unit –› WBI- WBI-2010 WBI- WBI-17
Plus
2014
2030
WBI-2010
221-41599 O O O S
Direct (95mm)
S
Injection 221-48335-01 (ID 3.5mm; OD 5mm; Length 95mm) S (WBI-2010) S O
Method
(WBI) 221-75197 (ID 3.4mm; OD 5mm; Length 95mm, Deactivated, with wool* 2 , 5pcs) O O
221-41599-05 (ID 2.6mm; OD 5mm; Length 95mm, Deactivated, for 0.53mmID column, O
5pcs)
GC-2010 GC-17A GC-
Nexis
ver. 1-3
Specification GC-2030 Plus GC- GC-2014 GC-1700 14A GC-8A
GC-
2010
P/N GC-2025 GC-18A 14B
SPL-
Injection Unit –› 2030 SPL-2010 SPL-2014 SPL-17 SPL-14 SPL-G9
Plus
For SPME 221-75196* O O O
(ID 0.75mm; OD 5mm; Length 95mm, Deactivated, 5pcs )
For HS 10 221-76863-73 (ID 1.2mm; OD 5mm, Length 95mm, Deactivated, 5pcs) S S S
WBC 221-38107 * 1 S S
Attach- (139mm)
ment 221-39148 S
(86 mm)
* 1 Required if the WBC Attachment is used for a packed column injection in GC-2014, Insert for GC-14 septum purge unit is P/N: 221-38151-04
* 2 Wool is 25mm from the top of insert.
* Can be used for AOC-6000 SPME
Pg C-68