Page 183 - Shimadu Consumables Catalog
P. 183

Capillary Columns
           Dedicated Columns


              SH-VRX
              Proprietary Crossbond phase
              Application-specific columns for volatile organic pollutants.

              Excellent for U.S. EPA Method 8021 compounds.
              Stable to 260 °C.
              Similar Phase(s): DB-VRX

               ID       df           Temp. Range                                 25 m
             0.10 mm  0.50 µm       -40 to 240/260 °C                         227-36331-01


              SH-PCB

              Proprietary Crossbond phase
              Unique polymer for PCBs analysis by GC-ECD or GC-MS.
              Good results for other semi-volatiles.

              Low polarity; inert to active compounds.
              Stable to 340 °C.
               ID       df           Temp. Range                                 60 m
             0.25 mm  0.25 µm       30 to 320/340 °C                          227-36310-01





          Aroclor PCBs
                                                                         Conditions
                                                                        Column    :  SH-PCB 60m, 0.25mm ID,
                                                                                    0.25μm (227-36310-01)
                                                                        Sample    :  Aroclor® 1242 (cat.# 32009),
                                                                                    1254 (cat.# 32011),
                                                                                    1262 (cat.# 32409), 333ppm each
                                                                        Inj.      :  1.0µL splitless (hold 0.75 min.),
                                                                                    4mm single gooseneck inlet liner w/
                                                                                    wool (cat.# 22405)
                                                                        Inj. temp.   :  280°C
                                                                        Carrier gas   :  helium, constant flow
                                                                        Flow rate   :  1.1mL/min.
                                                                        Oven temp.   :  100°C (hold 1 min.) to 200°C @ 30°C/min.,
                                                                                    to 320°C @ 2°C/min. (hold 1 min.)
                                                                        Det.      :  MS
                                                                        Transfer line   :  280°C
                                                                        Scan range   :  50 to 550amu
                                                                        Ionization   :  EI
                                                                        Mode      :  scan

















                                                                                                          Pg C-33